sdi410C, sti410C, sda410C, sta410C, sai410C, saa410C

EN RU

Vers. 1.04

 

This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled    

 

 

 

or discarded according to applicable local and national regulations.

   Equipment intended for indoor usage only.

  This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065, RoHS norm EN50581.
   This product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of technical 

  equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
  This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.

1. Product description

DVB-S/S2 (sdi410C, sda410C),  DVB-T/T2/C (sti410C, sta410C), DVB-ASI (sai410C, saa410C)  to IP  streamers (in text 

- module) designed to broadcast in multicast on an IP network the services (TV or Radio programmes) issued from FTA or 

encrypted digital reception; in case of encrypted signal, a CAM containing the operator's smart card must fit the slot. The IP 

streams can be viewed using an IPTV set-top box or a software video player. Modules sda410C, sta410C, saa410C have 

additional DVB-ASI output with unfiltered full transport stream.

Modules are intended for indoor use only. 

2. Characteristics

Input: one DVB transport stream (MPTS). 

Output: up to 24 simultaneous, IP-encapsulated services (TV or Radio programs), with individual multicast addresses 

and one MPTS stream. 

 BISS descrambling (sda410C, sta410C, saa410C modules).

 Information filtering of DVB tables.

 UDP & RTP transmission protocols.

 Web interface for configuration and setting.

 SNMP agent for monitoring and alarms.

 SAP & SDP protocols that facilitate automatic service selection on the user's STB and provide information to external 

servers.

 PID filtering.

 PSI/SI parsing.

 Transparent ECM & EMM messaging.

 PAT, PMT and SDT table regeneration.

 Routing or blocking for CAT, EIT, TDT tables.

 Configurable QoS marking.

 Configurable Time To Live.

3. Safety instructions

Installation of the module must be done according IEC60728-11 and national safety standards. 

Any repairs must be made by qualified personnel.

Do not expose this module to moisture or splashing water and make sure no objects filled with liquids, such as vases, 

are placed near or on the unit.

Avoid placing the module next to heat sources such as central heating components or in areas of high humidity.

Keep the converter away from naked flames.

If the module has been kept in cold conditions for a long time, bringing it into a warm environment may cause 

condensation, so allow it to warm up for no less than 2 hours before plugging into the mains.

Ventilation should not be impeded by covering the module, such as newspapers, table-cloths, curtains etc.

Mount the module in a vertical position only. If installing in a 19” rack system additional forced air cooling fans may be 

required (see table "

Technical specifications

" - operating temperature range).

Always allow 10 cm of free space from the top, front and bottom of the unit to enable any heat to be dissipated.

Summary of Contents for saa410C

Page 1: ...ual multicast addresses and one MPTS stream BISS descrambling sda410C sta410C saa410C modules Information filtering of DVB tables UDP RTP transmission protocols Web interface for configuration and setting SNMP agent for monitoring and alarms SAP SDP protocols that facilitate automatic service selection on the user s STB and provide information to external servers PID filtering PSI SI parsing Trans...

Page 2: ...r to the wall Parallel to the wall Figure 2 Mounting of the streamer 1 CA module slot PCMCIA socket 2 RF input of SAT IF signal DC output for LNB sdi410C sda410C RF input of terrestrial TV cable TV DC output for preamplifier sti410C sta410C DVB ASI input sai410C saa410C F socket 3 RF output input signal loop through F socket 4 ETHERNET control Ethernet interface RJ45 socket 5 ACTIVITY yellow indic...

Page 3: ...3 1 2 Mounting on DIN rail Figure 5 Mounting or removing to from DIN rail of plastic spacers supplied Figure 3 Mounting to DIN rail Figure 4 Mounting from DIN rail ...

Page 4: ...e and password The default user name and password is admin Enter the user name and password and click on Login button Note the default password admin can and must be changed as explained on section 7 8 5 During initial configuration you need to change the default control and streaming Ethernet interfaces TCP IP configuration as explained on section 7 5 Control interface IP address reset to default...

Page 5: ...gure 9 for sdi410C sda410C module consists of following parameters LNB LO frequency the LNB local oscillator lower frequency in megahertz Use 9750 MHz for the universal converter LNB HI frequency the LNB local oscillator upper frequency in megahertz Use 10600 MHz for the universal converter LNB voltage power supply of the converter can be set to Off Auto 13V 18V 13V 22kHz 18V 22kHz If Auto is sele...

Page 6: ...displayed only if the streamer module has synchronised with the input signal Modulation standard detected standard of the input signal Possible values of the standard DVB S DVB S2 sdi410C sda410C DVB T DVB T2 DVB C sti410C sta410C Frequency intermediate frequency sdi410C sda410C or RF frequency sti410C sta410C at the module input Modulation modulation scheme of the input signal Possible values of ...

Page 7: ...selected channel The module will start an UDP unicast streaming via the control interface Maximum output bitrate of the UDP unicast is 8 Mbps VLC Media Player must be installed downloadable from http www videolan org Figure 14 UDP streaming video The checkboxes in the Descramble column are used to select services for descrambling by CA module Several services can be selected if the module supports...

Page 8: ...he data flow is served at the correct speed for its projection in real time TS packet count count of the MPEG2 TS packets in the UDP packet Can be selected from one to seven It is recommended to select the value of seven packets Time To Live a parameter used to restrict the stream multicasting range A number between 1 and 255 is entered in this box Each time that an IP stream passes through a rout...

Page 9: ...o individually configure the output streams Figure 19 Output streams table The description of the table columns Enable enable streaming of service IP address the multicast address required for the stream to be added The available range is from 224 0 0 0 to 239 255 255 255 but it is recommended to reduce it from 224 0 1 0 to 238 255 255 255 IP port the IP port required for the stream to be added Th...

Page 10: ...ts SAP SDP protocol The name that the service has on the input transport stream is the default name Also this name will be used as the output service name New service provider enter the provider name of the output stream This name will be used in the SDT table Within the Enable checkboxes next to the stream PIDs is possible to select the streams to be broadcast for eath service the video PID canno...

Page 11: ...module from the Internet It is possible to control the module via streaming interface Check the enable WEB control from streaming interface checkbox to enable this function Note for security reasons WEB control from streaming interface schould be disabled 7 6 CAM settings This screen consists of three tables CA module monitor CA module information and CA module menu In the CA module monitor table ...

Page 12: ...s a password that is shared by multiple SNMP agents and one or more SNMP managers The Read Community password is used for read only access to streamer parameters Write Community is the password used for read write access to streamer parameters Enable TRAP SNMP traps are alerts generated by agents on a managed device Check this box to enable TRAP generation The streamer generates traps when the dia...

Page 13: ...e mouse on the System menu tab then click on the Export parameters line A window is displayed which allows you to select the action for the data file for the current streamer configuration You need to select the save file to disk option 7 8 3 Import parameters Select this option in System menu tab The Import parameters window is displayed Figure 25 Import parameters window Click on Click to select...

Page 14: ...ord in the appropriate fields select desired role for user and press the Add button to add new user or Update button to change settings of the user User role Admin enables the password change function and user management function User role User enables only password change function Press the Remove button to remove user from list 7 8 6 Restore defaults Clicking on the Restore defaults submenu in t...

Page 15: ... 188 204 bytes bit rate up to 72 Mbps up to 72 Mbps input voltage 200 880 mVpp 200 880 mVpp impedance 75 Ω 75 Ω return loss 15 dB 15 dB LNB powering control 0 14 18 V 0 14 18 V 300 mA max 300 mA max DiSEqC 1 0 DiSEqC 1 0 DC output for preamplifier max 12 V 100 mA 12 V 100 mA IP output standard IEE802 3 10 100 Base T bit rate up to 100 Mbps number of simultaneous up to 24 streams transmission proto...

Page 16: ...нными групповыми адресами и одним потоком MPTS дескремблирование потоков зашифрованных в кодировке BISS модели sda410C sta410C и saa410C фильтрация информации в таблицах DVB поддержка протоколов управления передачи данных UDP и RTP веб интерфейс для режимов конфигурирования и настройки SNMP агент для наблюдения и сигнализации о необычном событии поддержка протоколов SAP и SDP облегчающих автоматич...

Page 17: ...ри наличии входного сигнала индикатор состояния 12 горит мерцающим светом мигает с интервалом примерно три раза в секунду при отсутствии входного сигнала индикатор мигает с периодичностью примерно один раз в секунду 1 PCMCIA гнездо для установки модуля условного доступа 2 РЧ вход для приема ПЧ СТВ сигналов DC выход для питания LNB sdi410C sda410C РЧ вход наземного ТВ кабельного ТВ DC выход для пре...

Page 18: ...ь или угольник к стене стальными болтами или саморезами диаметром 3 5 4 мм Крепежные элементы не входят в комплект поставки Крепление к стене саморезами Крепление на угольнике входит в комплект поставки 1 2 Крепление к планке DIN rail Рис 3 Крепление к планке DIN rail Рис 4 Демонтаж с планки DIN rail ...

Page 19: ...компьютера должен быть назначен в следующем диапазоне 192 168 1 2 192 168 1 254 не использовать значение 192 168 1 10 так как оно является IP адресом конфигурируемого модуля Для начала процесса конфигурации модуля откройте веб браузер и наберите в адресной строке следующий IP адрес http 192 168 1 10 На экране появится окошко с запросом входа в систему см рис 6 Доступ к сайту защищен паролем и имен...

Page 20: ...тва Модель модуля Serial number Серийный номер Серийный номер модуля Software version Версия программного обеспечения Номер версии программного обеспечения модуля Hardware version Версия аппаратного обеспечения Номер версии аппаратного обеспечения модуля IP 1 IP адрес управляющего интерфейса IP 2 IP адрес потокового интерфейса System time Системное время Текущее время синхронизированное по таблице...

Page 21: ...600 LNB LO 9750 тогда F 950 10600 2150 9750 2 11725 МГц При установке питания конвертера на значение отличное от Auto строки LNB HI frequency Satellite и Polarization дезактивируются а для целей расчета промежуточной частоты используется значение нижней частоты конвертера Satellite Спутник Используйте команду DISEQC для выбора спутника при наличии коммутатора поддерживающего протокол DISEQC Другие...

Page 22: ...радиочастота для моделей sti410C и sta410C на входе в модуль Modulation Модуляция Схема модуляции входного сигнала Возможные значения QPSK 8PSK для моделей sdi410C и sda410C QPSK QAM16 QAM32 QAM64 QAM128 QAM256 для моделей sti410C и sta410C Modulation mode Режим модуляции Модуляция входного сигнала в режиме OFDM для моделей sti410C и sta410C Возможные значения 8k или 2k FEC Прямая коррекция ошибок...

Page 23: ...ткости телевизионная программа высокой четкости радиопрограмма Для просмотра выбранного канала нажмите на кнопку Watch Просмотр Модуль начнет одноадресную потоковую передачу контента по протоколу UDP через управляющий интерфейс с максимальной скоростью потока на выходе 8 Мбит сек Должен быть установлен VLC медиаплейер который можно загрузить по адресу http www videolan org Рис 14 Трансляция потоко...

Page 24: ...поддерживают функцию дескремблирования потоков защищенных в системе кодирования BISS Код BISS для программы зашифрованной с помощью этой системы кодирования можно ввести в таблице Подробные сведения о программе рис 16 Рис 16 Таблица для ввода кода BISS Введите код BISS в шестнадцатеричном формате в поле BISS code Код BISS и нажмите кнопку Update Обновить 7 4 Output settings Настройки параметров вы...

Page 25: ...ока 3 Low priority video Низкий приоритет видеопотока 4 Video and voice Видео и аудио 5 Best effort Максимально доступное качество доставка видеоданных и соответствующих аудиоданных с максимально возможным качеством Count of output streams Число выходных потоков Число выходных потоков отображаемых в таблице Output streams Выходные потоки ниже Параметр может быть задан числом от 1 до 25 После обнов...

Page 26: ...ковой передачи данных IP address IP адрес Групповой адрес потока Доступный диапазон адресов 224 0 0 0 239 255 255 255 однако рекомендуется ввести адрес в несколько суженном диапазоне от 224 0 1 0 до 238 255 255 255 IP port IP порт IP порт потока Значение по умолчанию 1234 Service title Название программы Название программы выбрать из доступных входящих программ Предусмотрена возможность активации ...

Page 27: ...анслироваться в составе программы при этом пакетный идентификатор видеопотока не может быть деактивирован По умолчанию включены кнопки флажки всех идентификаторов которые остаются в активированном состоянии до момента внесения соответствующих изменений пользователем Нажмитекнопку Update Обновить дляподтверждениянастроекизакройтетаблицупутемнажатиянапиктограмму 7 5 IP settings Настройки параметров ...

Page 28: ...nu Меню модуля условного доступа на рис 22 показывает вид меню для конкретного типа модуля При нажатии на соответствующей полосе таблицы открывается доступ к различным пунктам меню Для возврата в предыдущее меню нажмите кнопку Back Назад а для выхода в стартовое меню нажмите кнопку Home Возврат 7 7 SNMP settings Настройки протокола SNMP Данная вкладка меню содержит таблицу SNMP configuration Конфи...

Page 29: ...м последние события показаны в начале списка Строки с информационными событиями выделены синим цветом а с сообщениями об ошибках красным После включения устройства текущая дата устанавливается на 2000 01 01 а время на 00 00 00 При получении MPEG потока информация о дате и времени декодируется а их значения в таблице соответственно корректируются Сдвиг местного времени в журнале принимается по табл...

Page 30: ... при этом появится окно с запросом подтверждения загрузки 7 8 4 Firmware upgrade Обновление встроенного программного обеспечения Нажмите кнопку Click to select file Выбрать файл и выберите с жесткого диска файл обновления встроенного ПО После появления имени файла в соответствующем поле окна нажмите кнопку Upload Загрузить На стример будет установлена новая версия встроенного ПО Рис 26 Окно Firmwa...

Page 31: ...пункта во вкладке System menu Системное меню выполняется перезагрузка модуля стримера 7 8 8 Language Язык Если хотите изменить язык меню стримера то выберите данный пункт во вкладке System menu Системное меню без внешней нагрузки по ПТ и CAM с CAM 0 3 A Тип sdi410C sti410C sai410C sda410C sta410C saa410C РЧ вход QPSK 8PSK COFDM QAM QPSK 8PSK DVB C COFDM QAM частотный диапазон 950 2150 MHz 47 862 M...