1. Product description

The devices are transmodulators with 8 DVB-S/S2 input channels and 8 DVB-T/ISDB-T (tdx480), 4 DVB-T/ISDB-T (tdx440), 

8 DVB-C/J.83B (tdq480), 4 DVB-C/J.83B (tdq440) output channels. The devices are designed for digital transmodulation with 
Transport Stream Processing of TV or Radio programmes issued from FTA (Free to air) or encrypted digital reception. Devices 

filter services, modify SI (Service Information), generate NIT (Network Information table), LCN (Local Channel Number), 
can remultiplex services from any input to any output. All of the configurations can be changed by using the Web Interface.

tdx440 

 – quad transmodulator - with eight DVB-S/S2 input channels and four DVB-T/ISDB-T output channels.

tdx480 

 – octal transmodulator - with eight DVB-S/S2 input channels and eight DVB-T/ISDB-T output channels.

tdq440 

 – quad transmodulator - with eight DVB-S/S2 input channels and four DVB-C/J.83B output channels.

tdq480 

 – octal transmodulator - with eight DVB-S/S2 input channels and eight DVB-C/J.83B output channels.

Transmodulators can be used as stand alone devices.
The product is intended for indoor usage only.

2. Safety instructions

Installation of the transmodulator must be done according IEC60728-11 and national safety standards. 

Any repairs must be made by skilled personnel. 
Do not expose this transmodulator to moisture or splashing water and make sure no objects filled with liquids, such as 

vases, are placed near or on the unit. 

Avoid placing the transmodulator next to heat sources such as central heating components or in areas of high humidity. 

Keep the transmodulator away from naked flames. 
If the transmodulator has been kept in cold conditions for a long time, bringing it into a warm environment may cause 

condensation, so allow it to warm up for no less than 2 hours before plugging into the mains. 

Ventilation should not be impeded by covering the transmodulator, such as newspapers, table-cloths, curtains etc. 

Mount the transmodulator in a vertical position only. If installing in a 19” rack system additional forced air cooling fans 

may be required (see table "Technical specifications" - operating temperature range). 

Always allow 10 cm of free space from the top, front and bottom of the unit to enable any heat to be dissipated.

EN

Summary of Contents for TDQ440

Page 1: ...ut channels and four DVB T ISDB T output channels tdx480 octal transmodulator with eight DVB S S2 input channels and eight DVB T ISDB T output channels tdq440 quad transmodulator with eight DVB S S2 input channels and four DVB C J 83B output channels tdq480 octal transmodulator with eight DVB S S2 input channels and eight DVB C J 83B output channels Transmodulators can be used as stand alone devic...

Page 2: ...lt IP address of the control Ethernet interface Ethernet led indicators activity 3 and link 4 will start to toggle to inform that the reset IP address request has been accepted Device will be restarted with default IP address To restore all parameters to default values including password keep pressing the button for additional 4 seconds The green link indicator will start blinking after that time ...

Page 3: ... off when there is no link the ACTIVITY 3 indicator blinks if communication via the control Ethernet interface is active Package contents 1 Transmodulator 1 pcs 2 Holder 1 pcs 3 Spacer 1 pcs 4 75 Ω terminator 1 pcs 5 Bridge F quick to F quick 1 pcs 6 User manual 1 pcs 5 MOUNTING The module or mounting bracket must be fixed with steel screws Ø 3 5 4 mm The screws are not included in a package Mount...

Page 4: ...il of plastic spacers supplied Figure 3 Mounting to DIN rail Figure 4 Mounting from DIN rail DC IN 12V tdx440 RESET ETHERNET TERRA IN1 IN 2 THRU1 THRU 2 DC IN 12V tdx440 RESET ETHERNET TERRA IN1 IN 2 THRU1 THRU 2 DC IN 12V tdx440 RESET ETHERNET TERRA IN1 IN 2 THRU1 THRU 2 ...

Page 5: ...he default user name and password is admin Enter the user name and password and click on Login button NOTE the default password admin can and must be changed as explained in the section 6 10 5 User management During initial configuration you need to change the default control interface TCP IP configuration as explained in the section 6 8 IP settings NOTE If you are using Internet Explorer Web brow...

Page 6: ...tual bitrate would not reach more than 95 of available bandwidth Otherwise bitrate overflow may occur System status table It represents the following parameters at real time Processor load in percents internal temperature in degrees of Celsius power voltage in Volts Other device in the network If there are any modules in the network their status and diagnostic information will be displayed as it i...

Page 7: ...and Slave for modules connected by loop through If Slave was selected additionally type the IP address of Master module All the modules in the dSCR SCR group must be in the same Ethernet network Next select SAT input and User band type in frequencies symbol rate press Update button and observe dSCR status SCR same as dSCR just the user band frequencies must be typed in manually as shown in Figure ...

Page 8: ...CN for that service is not used at all and TV will sort these channels according to it s own rules Services can be passed to any output number independing on the input demodulator number BISS scrambled services have a checkbox for descrambling Press onto sign and service information will be extended see Figure 15 Service details Figure 15 Service details Service title and provider can be edited mu...

Page 9: ...depending on your country and operator can be found here http www dvbservices com identifiers network_id page 1 Private data specifier in hex format can be inserted in the NIT table for proper LCN description This value is described in TS 101162 specification NorDig standard requires 00 00 00 29 value UK should use 00 00 23 3A value Other options can be found here http www dvbservices com identifi...

Page 10: ...able checkbox will enable channel to the output Global attenuator can be entered up to 15 dB Also there is individual precise attenuator up to 2 5 dB in step of 0 5 dB Press Update to change settings In case if any modulation parameter was changed both channels will be restarted with new settings Exception is Attenuator changes in this parameter will not restart the modulator Figure 19 DVB C outpu...

Page 11: ...all default values Figure 20 IP settings table 6 8 E mail settings The device can send e mail reports if errors were detected SMTP protocol is used for that Figure 21 E mail settings table shows parameters related to this feature Enable e mail error report checkbox enables error monitoring All errors within timeout period will be gathered and send to the e mail address provided in Receiver e mail ...

Page 12: ...k to the device Press onto Click to select file button see Figure 24 Import parameters to select exported file Figure 24 Import parameters Press Upload button to send the file to the device It will take several seconds to update all parameters after file upload After that device will function with new configuration No restart is required 6 10 4 Firmware upgrade Device firmware can be upgraded via ...

Page 13: ... user access account for another person you take full responsibility for all module settings modifications made by that person or anyone else they may give the password to 6 10 6 Restore defaults All parameters will be restored back to factory defaults after confirmation The exception IP address and users these parameters will be unchanged To restore IP address and system password to system defaul...

Page 14: ...ource from TS as shown in the Figure 27 Figure 27 Date Time settings table 6 10 9 Language Device control panel supports several preinstalled languages A change of language requires system restart Note that all previously logged records will remain in previous language Additional languages can be installed under request Contact our distributors for such possibility ...

Page 15: ...tion QPSK QAM16 QAM64 QAM16 QAM32 QAM64 QAM128 QAM256 channel bandwidth 7 MHz 8 MHz 4 8 3 MHz guard interval 1 4 1 8 1 16 1 32 code rate 1 2 2 3 3 4 5 6 7 8 symbol rate 3 5 7 2 Ms s return loss 10 dB roll off 15 transmission mode 2K 2K 8K total output level 0 15 0 dB by 1 dB step adjustment range loop through frequency 47 862 MHz 2 5 dB range loss Management port standard IEE802 3 10 100 Base T Su...

Page 16: ...мате DVB S S2 и четырьмя выходными каналами для передачи сигналов в формате DVB T ISDB T tdx480 трансмодулятор с восемью входными каналами для приема сигналов в формате DVB T T2 C и восемью выходными каналами для передачи сигналов в формате DVB T ISDB T tdq440 трансмодулятор с восемью входными каналами для приема сигналов в формате DVB S S2 и четырьмя выходными каналами для передачи сигналов в фор...

Page 17: ...ию 192 168 1 10 нажав и удерживая кнопку RESET сброс по меньшей мере 3 сек Светодиодные индикаторы Ethernet интерфейса активности 3 и соединения 4 начнет мигать информируя о том что запрос на сброс IP адреса принят Устройство перезапустится с IP адресом по умолчанию Чтобы восстановить все параметры до значений по умолчанию включая пароль удерживайте кнопку еще 4 сек По истечении этого времени начн...

Page 18: ...net загорается индикатор соединения 4 При активном состоянии связи через управляющий интерфейс Ethernet индикатор активности 3 горит мерцающим светом мигает 5 Крепление Прикрепите модуль или угольник к стене стальными болтами или саморезами диаметром 3 5 4 мм Болты и саморезы не входят в комплект поставки Угольник или планка DIN rail должны быть подсоединены к основной шине выравнивания потенциало...

Page 19: ...иковых вставок входят в комплект поставки Рис 3 Крепление к планке DIN rail Рис 4 Демонтаж с планки DIN rail DC IN 12V tdx440 RESET ETHERNET TERRA IN1 IN 2 THRU1 THRU 2 DC IN 12V tdx440 RESET ETHERNET TERRA IN1 IN 2 THRU1 THRU 2 DC IN 12V tdx440 RESET ETHERNET TERRA IN1 IN 2 THRU1 THRU 2 ...

Page 20: ...олчанию admin может и должен быть сменен в порядке изложенном в пункте 6 10 5 Управление пользователями В процессе начального конфигурирования необходимо изменить стандартные настройки протоколов TCP IP управляющего интерфейса Ethernet в порядке изложенном в пункте 6 8 IP настройки Внимание При использовании программы Internet Explorer ее версия должна быть 10 0 и выше Порядок сброса IP адреса упр...

Page 21: ... передачи данных в Мbps Следующее число показывает максимально допустимую скорость передачи данных по каналу которая определяется параметрами модуляции Величина параметра не должна превышать 95 в противном случае может наступить перегрузка по скорости передачи данных Таблица Состояние системы В таблице в режиме реального времени отображаются следующие параметры нагрузка на процессор в процентах вн...

Page 22: ...dSCR SCRmode Основной или Вспомогательный Основной выбирается для модулей имеющих прямое соединение с распределителем сигналов Unicable мультисвич или LNB и Вспомогательный для модулей включенных через сквозной проход входного РЧ сигнала При выборе режима Вспомогательный необходимо дополнительно указать IP адрес модуля Основной Все модули группы dSCR SCR должны быть в одной сети Ethernet Далее выб...

Page 23: ...орый может быть присвоен каждой программе Сортировка каналов ТВ приемником производится на основе этих номеров при этом необходимо обеспечить что все программы во всех каналах имеют разные номера Нулевой номер означает что номер логического канала LCN для данной программы не используется и в таком случае ТВ приемник выполняет сортировку таких каналов на основе своих правил Программы могут быть пер...

Page 24: ...аблица Глобальные параметры TS определяет следующие параметры потоков Идентификатор сети Network ID уникальный номер в пределах географического региона заданного кодом страны Для кабельной сети идентификатор обычно состоит из кода единичной страны плюс 0x2000 8192 При подключении в сеть двух и более модуляторов они должны иметь один и тот же присвоенный идентификатор сети Значения идентификаторов ...

Page 25: ...чение требуемой частоты Шаг частоты равен is 0 1 MHz Активация выходного канала выполняется путем постановки галочки в кнопке флажке Включено Допустимая величина ослабления аттенюатора не выше 15 dB Также имеется индивидуальный точный аттенюатор до 2 5 dB с шагом 0 5 dB Для сохранения внесенных изменений нажмите на кнопку Обновить В случае изменения любого параметра модуляции выполняется перезагру...

Page 26: ...лочку в кнопке флажке Включить отчет об ошибках по электронной почте В этом случае в течение установленного периода времени будет выполняться сбор всех выявленных ошибок и их пересылка по адресу электронной почты указанному в поле Адрес электронной почты получателя Для пересылки отчета об ошибках нескольким получателям в поле необходимо ввести соответствующие адреса электронной почты через запятую...

Page 27: ...ь журнал все записи в журналах будут удалены из системы При нажатии на кнопку Експортировать журнал создается файл log html который может быть загружен на компьютер пользователя Время наступления каждого события указывается в строке с его описанием Порядок настройки параметров времени изложен в пункте 6 10 8 Дата Время Рис 23 Таблица Журнал событий 6 10 2 Экспортировать параметры Все настройки тра...

Page 28: ... не отключайте устройство от сети питания Устройство обладает возможность загрузки хронологии версий ПО и проверки наличия его новых версий Для проверки наличия новых версий ПО нажмите на ссылку Проверьте онлайн нет ли новой прошивки Если Ваш компьютер но не устройство имеет доступ к сети интернет то на его экран будет выведен список всех версий ПО со ссылками для загрузки соответствующих бинарных...

Page 29: ...бом перезагрузки является нажатие на кнопку RESET Сброс во время работы устройства 6 10 8 Дата Время Системное время может быть задано вручную либо принято с сервера NTP при условии что модуль имеет доступ к такому серверу Кроме того предусмотрена возможность выбора источника времени из транспортного потока Time from TS как показано на рис 27 Рис 27 Таблица Дата Время 6 10 9 Язык Устройство поддер...

Page 30: ...53 Mbit s MER 35 dB 40 dB модуляция QPSK QAM16 QAM64 QAM16 QAM32 QAM64 QAM128 QAM256 ширина полосы 7 MHz 8 MHz 4 8 3 MHz защитный интервал 1 4 1 8 1 16 1 32 коэффициент избыточности 1 2 2 3 3 4 5 6 7 8 скорость цифрового потока 3 5 7 2 Ms s возвратные потери 10 dB спад 15 режим передачи 2K 2K 8K диапазон регулирования 0 15 dB с шагом 1 dB вых уровня суммарного сигнала частотный диапазон 45 862 MHz...