Line Interactive UPS 

                                                                400/600/800 VA 

Inspection

 

The following items are inside the box: 

 

UPS unit                    User Manual 

Remove the UPS from its package and inspect it for damage that 
may have occurred during shipping.    If any damage is discovered, 
re-pack the unit and return it to the place of purchase. 
 

Connect to Utility Power

 

Connect AC power cord to utility power. Then, the UPS will start to 
charge inside battery. For best result, charge the battery for 6 hours 
prior to initial use. 

     

 

 

Turn On the UPS 

To turn on the UPS unit, press the power switch lightly. Then, the 
LED will light up. 
 

Turn Off the UPS 

To turn off the UPS unit, press the power switch again. Then, the 
LED will go off. 
 

Cold Start Function

 

When the UPS is off and there is no power utility, it's still possible to 
cold start the UPS unit to power the loads. 
 

Free Software Download (Option)

 

Go to the website 

http://www.power-software-download.com

 and 

download the ViewPower software. Follow on-screen instruction to 
install the software. When your computer restarts, the monitoring 
software will appear as an orange plug icon located in the system 
tray, near the clock. 
 

 

 
 
 
 
 
 
 
 
 
 

Indicator 

Meaning 

Green LED solid on 

Utility power is normal. The UPS is on 

AC mode. 

Green LED flashing 

Utility power fails and the UPS is 

supplying power from battery. 

Plug in Equipment

 

Plug your equipment to Battery Backup Outlets on the rear panel of 
the UPS.   

 

NOTE: 

Make sure that the UPS is powered on to protect all 

important devices from data loss during power failure. 

 

Monitor 

Computer 

CAUTION: NEVER 

connect a laser printer or scanner to the 

battery backup outlets of UPS. The equipment may draw 
significantly power to overload the UPS. 
 

 

 

 

Battery backup outlets:

 

Plug sensitive equipment into battery backup outlets. Battery 
power is automatically provided in case of a power outage. 

AC input

Fuse (option):

 

The fuse will be burned out if an overload condition forces the UPS 
to disconnect itself from utility power. 

USB com. port (option): 

To monitor the UPS status, such as unattended UPS shutdown and 
start-up, by using download software, please connect the UPS and 
PC with USB cable included. 

Modem/Phone line surge protection (option): 

Connect a single modem or phone line into surge-protected 

“IN” 

outlet on the back panel of the UPS unit. Connect from 

“OUT” 

outlet to the computer with another phone line cable. 
 

 

Battery mode: 

When the UPS is in battery backup mode (battery mode), the 
green LED will flash and the UPS sounds an audible alarm every 
10 seconds. 

Low battery:   

When the UPS is in battery backup mode (battery mode) and the 
battery energy begins to run low, the UPS will beep every second. 

Overload: 

When the UPS is overloaded, the UPS will beep every 0.5 second 
to warn an overload condition.   

Fault: 

When there a UPS fault occurs, the UPS will continuously beep. 