background image

 

 USER MANUAL 

T-100 SERIES 

UNINTERRUPTIBLE POWER SUPPLIES 

( 1 Phase Input & Output ) 

T-102 

2 kVA 

T-103 

3 kVA 

T-106 

6 kVA 

T-107 

7,5 kVA 

T-110 

10 kVA 

T-115 

15 kVA

 

 

Summary of Contents for T-100 Series

Page 1: ...USER MANUAL T 100 SERIES UNINTERRUPTIBLE POWER SUPPLIES 1 Phase Input Output T 102 2 kVA T 103 3 kVA T 106 6 kVA T 107 7 5 kVA T 110 10 kVA T 115 15 kVA...

Page 2: ......

Page 3: ...pted 10 4 4 Operator Control Panel 10 4 4 1 Push buttons 10 4 4 2 First message Up line of the LCD 11 4 4 3 Second message line of the LCD 12 4 5 Automatic battery test system optional 12 V OPTIONAL E...

Page 4: ......

Page 5: ...ed service personnel The output may be energized when the unit is not connected to a mains supply Risk of electric shock hazardous live parts inside this unit are energized from the battery supply eve...

Page 6: ...atic battery testing optional High quality maintenance free lead acid type batteries High nonlinear load capacity special for computers Accessories o Optional UPS monitoring software T MON RUPS RUPSII...

Page 7: ...is an electronically controlled switching circuit checked by main controller board In case of inverter overload or any other faults STS transfers the critical load to the mains without any interruptio...

Page 8: ...Voltage Tolerance 1 Output Frequency 50 Hz Output Frequency Tolerance Line Synchronized 1 Free Running 0 2 Efficiency 100 Load 85 87 Crest Factor 3 1 Overload capacity 100 125 Load 2 5 min 125 150 Loa...

Page 9: ...Switch AC Input AC Output Output Fuse F4 External battery socket DB9 Port 2 3 kVA DB9 Port AC Output Main Switch PK1 On Off Switch UPS electrical connections 6 7 5 kVA 10 kVA Figure 2 2 Rear views DB...

Page 10: ...Selection The UPS is designed to be installed in a protected environment The following conditions should be prohibited 1 Blocking the airflow intake and outlet It is recommended to retain 10 cm 4 mini...

Page 11: ...d to the line voltage protected by a circuit breaker 1 Before connecting AC and DC power to the UPS make sure that the On Off Switch PK1 and Main Switch on the rear panel are in the 0 position OFF 2 C...

Page 12: ...ll sound intermittently Now the output receptacles are supplied from the battery source 4 Connect the power again and see that LINE FAILURE alarm is off 5 Now your UPS is ready to operate Plug in the...

Page 13: ...rotect your critical loads from loss of data or damage Battery back up time is more than 10 minutes for full load and can be extended by removing non critical loads After an utility power blackout the...

Page 14: ...button will change the status BATT USED It shows battery operation time the time passed after the last line failure alarm MOD ONLINE MOD ECONO This parameter determines the operation type of the UPS...

Page 15: ...out of tolerance ONLINE MODE UPS operating mode is ONLINE mode ECONO MODE optional This message shown the alternate operating mode is active OFFLINE 4 5 Automatic battery test system optional There ar...

Page 16: ...unicate so that the computer system is warned of impending UPS shutdown Software T MON RUPS RUPSII UPSILON 2000 and SNMP devices is available for most operating systems and is supplied with a signalin...

Page 17: ...ftware supplied with the module or it is possible to monitor the UPS through an Internet Browser It is possible to shutdown the servers or users with Client mate Software that communicates with SNMP m...

Page 18: ...system from several different locations at the same time 5 5 UPS Port Sharer Multiple server shut down unit Using one of this units you can automatic shut down of 4 8 servers or PC where without LAN...

Page 19: ...T 100 Series UPS User Manual 16...

Page 20: ...T 100 Series UPS User Manual 17 Connection Diagram Of The RMP COM1 T MON...

Page 21: ...iced only by authorized people In case of a persistent failure or problem properly turn off the unit first Then review the following check list Be prepared to answer the questions before calling the s...

Page 22: ...not apply if the product has been subjected to physical abuse improper installation unauthorized service or modification 2 The sole responsibility of corporation under this warranty shall be limited t...

Page 23: ...AGKK3772 02 2011...

Reviews: