background image

testo 623 

Ambient Condition Recorder 

Instruction manual 

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Summary of Contents for 623

Page 1: ...testo 623 Ambient Condition Recorder Instruction manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ...27 3 1 Technical data 27 4 Product description 28 4 1 Overview 28 4 2 Basic properties 30 5 First steps 30 6 Using the product 31 6 1 Commissioning 31 6 2 Setting the limits 32 6 3 Performing settings 32 6 4 Flowchart 33 6 5 Measuring 37 7 Maintaining the product 41 8 Tips and assistance 42 8 1 Accessories and spare parts 42 8 2 Questions and answers 42 Pos 2 TD Überschriften 2 Sicherheit und Umwe...

Page 3: ...necessary Hand this documentation on to any subsequent users of the product Pos 5 TD Sicherheit und Umwelt Zu diesem Dokument Symbole und Schreibkonventionen Symbole und Schreibkonv testo622 623 4 mod_1249373225894_79 doc 47075 5 Symbols and writing standards Representa tion Explanation Warning advice risk level according to the signal word Warning Serious physical injury may occur Caution Slight ...

Page 4: ...rheit und Umwelt Umwelt schützen Akkus Batterien entsorgen 0 mod_1175693637007_79 doc 619 Dispose of faulty rechargeable batteries spent batteries in accordance with the valid legal specifications Pos 12 TD Sicherheit und Umwelt Umwelt schützen Produkt entsorgen 0 mod_1173780307072_79 doc 357 At the end of its useful life send the product to the separate collection for electric and electronic devi...

Page 5: ...ty 24 months warranty conditions see website www testo com warranty EC Directive 2004 108 EC Pos 16 TD Überschriften 4 Produktbeschreibung 0 mod_1173774846679_79 doc 310 1 4 Product description Pos 17 TD Überschriften 4 1 Übersicht 0 mod_1176379946003_79 doc 733 2 4 1 Overview Pos 18 TD Produktbeschreibung Übersicht testo 623 testo 623 Bedienelemente 3 mod_1241078190938_79 doc 32254 Keypad Key Fun...

Page 6: ...ge settings select bar Confirm settings Cancel input Acknowledging an alarm Sensors Attachment device Battery compartment and instrument interface Mounting clip and wall fixture integrated into housing Pos 19 TD Überschriften 4 2 Grundlegende Eigenschaften 0 mod_1176380399692_79 doc 742 2 ...

Page 7: ...le is 63 mm Pos 22 TD Überschriften 5 Erste Schritte 0 mod_1173774895039_79 doc 319 1 5 First steps Pos 23 TD Erste Schritte testo 622 testo 622 Schutzfolie entfernen 3 mod_1233927965698_79 doc 23802 5 Removing the protective film Remove the protective film from the display Pos 24 TD Erste Schritte testo 622 testo 622 Batterie einlegen 3 mod_1233927372010_79 doc 23783 5 Inserting batteries recharg...

Page 8: ...hold or Press Esc to cancel settings without saving them Hold Set down for 2 s to save previously set values and leave the menu Instrument returns to the display Display Function Setting option DD MM YYYY flashes or MM DD YYYY flashes Set date format DD MM YYYY day month year MM DD YYYY month day year Year flashes Set year 2009 2099 Month flashes Set month 01 12 Day flashes Set day 01 31 24H or 12...

Page 9: ...c 46623 2 3 6 3 Performing settings 1 Press and hold Set for 2 s Display flashes 2 Select the required function with Set The adjustable parameter flashes 3 Set values with or and confirm entry with Set for settings see following table To scroll rapidly forward and back press and hold or Press Esc to cancel settings without saving them Hold Set down for 2 s to save previously set values and return ...

Page 10: ...ing the product Pos 29 TD Produkt verwenden testo623 testo 623 Ablauf_Ablaufdiagramm 4 mod_1254828714890_79 doc 51477 2 6 4 Flowchart A detailed description of the points can be found on the following pages ...

Page 11: ...is selected Lower limit value flashes Set value for lower temperature limit alarm and light up ON or OFF flashes Activate or deactivate display for upper humidity limit alarm Deactivate OFF Activate ON Only if ON is selected Upper limit value flashes Set value for upper humidity limit alarm and light up ON or OFF flashes Activate or deactivate display for lower humidity limit alarm Deactivate OFF ...

Page 12: ...lashes Deleting memory Deactivate OFF Activate ON Update date time lights up No flashes Set date and time No change Select Yes Select No Only if Yes is selected DD MM YYYY flashes or MM DD YYYY flashes Set date format DD MM YYYY day month year MM DD YYYY month day year Only if Yes is selected Year flashes Set year 2009 2099 Only if Yes is selected Month flashes Set month 01 12 Only if Yes is selec...

Page 13: ... PM flash Set time format 24H 12H Only if Yes is selected Hour flashes Set hour value 00 23 or 01 12 Only if Yes is selected Minute flashes Set minute value 00 59 Only if Yes is selected Second flashes Set second value 00 59 C flashes Set unit for temperature C F flashes Set unit for humidity td wb ...

Page 14: ...rrupted the settings are being saved for at least 3 min Pos 30 TD Überschriften 6 3 Messungen durchführen 0 mod_1184584650078_79 doc 1872 2 6 5 Measuring Pos 31 TD Produkt verwenden testo623 testo 623 Funktionen 3 mod_1241426519726_79 doc 32436 5555555 With max min the time that it occurred and the corresponding value C RH is shown Displaying max values Press Max If Max flashes the past max values...

Page 15: ... with or If the min temperature value is shown press to display the min humidity value If the Min key is not pressed for 5 min the screen automatically reverts to the current display Histogram Bar Bar segment Time interval Lower display value Displayed unit temperature or humidity Upper display value ...

Page 16: ...y is reached the oldest measurement values are automatically overwritten First in first out principle With Manual Scale The lowest bar element of a bar flashes The measured value is below the lower display value The uppermost bar element flashes The measured value is above the upper display limit Displaying the humidity temperature profile To change the profile between humidity and temperature Pre...

Page 17: ... temperature value and min humidity value Press Min Display history The history of the the last 90 days can be displayed with or Acknowledging an alarm Alarm was triggered LED flashes The reading that was exceeded or undershot flashes To clear an alarm Press Alarm Alarm is cleared With the alarm activated and a change to the setup menu the current alarm is acknowledged Pos 32 TD Überschriften 7 Pr...

Page 18: ...cally 3 Close the battery compartment If the power supply is interrupted the settings are being saved for at least 3 min If the instrument is not used over a longer period the batteries rechargeable batteries should be removed from the instrument to prevent damage to the instrument and the batteries rechargeable batteries Pos 34 TD Produkt instand halten testo 622 623 Gerät reinigen 4 mod_12548316...

Page 19: ...0520 0206 ISO humidity calibration certificate calibration points 11 3 RH and 75 3 RH at 25 C 0520 0006 Pos 38 TD Überschriften 8 1 Fragen und Antworten 0 mod_1177402017078_79 doc 1093 2 8 2 Questions and answers Pos 39 TD Tipps und Hilfe Fragen und Antworten testo 622 Fragen un d Antworten 4 mod_1254486946825_79 doc 51139 Question Possible causes Instrument displays LO Below 20 C Instrument displ...