background image

LED Lighting System

GE

Lighting

Installation Guide

imagination at work

24

Volt

(GEDS71-2, GEDS50-2, GEDS41-2, GEDS32-2, GEDSH71-3, GEDSH50-3, GEDSH41-3, GEDSH32-3)

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground Tetra

®

 power supply enclosure.

RISK OF FIRE
• Use only UL certified wire for input/output connections. 
  Minimum size 18 AWG (0.82mm

2

).

• Follow all NEC and local codes.

RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra

®

.

RISQUES D’INCENDIE
• N’utilisez que des fils approuvés par UL pour les entrées/sorties  

 

  de connexion. Taille minimum 18 AWG (0.82mm

2

).

• Respectez tous les codes NEC et codes locaux.

 CAUTION/ATTENTION

RISK OF INJURY
• While performing installations described, gloves, safety glasses  

  or goggles should be worn. 

RISQUE DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de sécurité  

  ou des lunettes de protection doivent être portées.

Prepare Electrical Wiring

Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be done in   
  accordance with National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit    
  from a Class 2 power source. These products have not been    
  evaluated for use when connected to a power source that does  
  not comply with Class 2 voltage and energy limited supplies.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Tetra

®

 PowerStrip DS

This device complies with part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must 

accept any interference received, including interference that 

may cause undesired operation.
Note:

 This equipment has been tested and found to comply 

with the limits for a Class A digital device, pursuant to part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This 

equipment generates, uses, and can radiate radio frequency 

energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential 

area is likely to cause harmful interference in which case the 

user will be required to correct the interference at his own 

expense.
This Class [A] RFLD complies with the Canadian standard 

ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003 

du Canada. 

Save These Instructions

Use only in the manner intended by the manufacturer.

If you have any questions, contact the manufacturer.

Summary of Contents for GEDS71-2

Page 1: ... local codes These products are only suitable for connection to a circuit from a Class 2 power source These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies BEFORE YOU BEGIN Read these instructions completely and carefully Tetra PowerStrip DS This device complies with part 15 of the FCC Rules Operation i...

Page 2: ...Clip or other suitable mounting means Ensure the 6 M3 screw does not exceed 3 4 inches 19 mm in length 1 2 3 Installation Sign Using Rails Measure inside Sign Tetra Mounting Rail Arrange modules evenly spaced apart Place the Tetra modules on the Mounting Rail and secure into lip with a self tapping 6 M3 screw or 1 8 inch 3 175 mm rivet Or mount using the alternative clip and extender rod configura...

Page 3: ...tch must be installed 4 Existing Signs Only Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an aluminum or zinc coated steel patch with rivets and sealant 5 Using the layout guidelines above determ...

Page 4: ...24 VDC Class 2 Power Supply SKU Rating 25W Power Supply Note Load shall not exceed 1 04A 80W Dimming Power Supply Note Load shall not exceed 3 3A 100W Power Supply Note Load shall not exceed 4 0A 180W Power Supply Note Load shall not exceed 4A per each of 2 output channels 300W Power Supply Note Load shall not exceed 4A each of 3 output channels GEDS71 2 GEDS50 2 GEDS41 2 GEDS32 2 24VDC 5 04W modu...