Summary of Contents for 1020915

Page 1: ...07061 01 LED spotlight with motion detector EN 1 Basic safety information 3 Proper use 3 Disposal 3 2 Description 4 3 Connection 4 4 Installation 5 Installation instructions 8 5 Walking test 10 6 Alignment 10 Limiting the detection area using stickers 11 ...

Page 2: ...2 7 Setting 12 Setting the brightness lux 12 Setting the time min 13 Manual operation 13 Setting the twilight switch function 14 8 Technical data 15 9 Contact 16 ...

Page 3: ...R conforms to EN 60598 1 if correctly installed Only intended for installation outside of arm s reach Proper use LED spotlight is used for lighting depending on presence and brightness Intended for wall mounting outdoors Suitable for corridors gardens entrances parks etc For use in normal ambient conditions Disposal Dispose of LED spotlight in an environmentally sound manner electronic waste ...

Page 4: ...et ting time min and brightness lux LED spotlight 3 Connection WARNING Danger of death through electric shock Disconnect power source Ensure device cannot be switched on Check absence of voltage Earth and bypass Cover or shield any adjacent live components ...

Page 5: ...5 N L N L L Do not touch the metal parts The device can get hot Do not install on flammable surface 4 Installation Ensure installation height of 2 5 m ...

Page 6: ...6 Use the accompanying mounting bar for flexible installation and cable entry 230V Disconnect power source Ø 6 mm Make marks for the holes and drill the holes Tighten the mounting bar ...

Page 7: ...7 Feed cable through the seal of the base Fix cord grip and tighten screws Connect the individual wires to the appropriate terminal ...

Page 8: ... LED spotlight on the mounting bar and tighten screws Connect LED spotlight to mains Installation instructions As the LED spotlight reacts to variations in tempe rature avoid the following situations Do not direct motion detectors PIR of the LED spotlight at objects with highly reflective sur faces such as mirrors etc Do not install the motion detector near heat sources such as heating outlets air...

Page 9: ...t run 1 80 2 O T 8 1 T E M 5 ER 1 2 M E T E R 3 METER 1 80 1 R E T E M 5 2 O T 8 1 2 M E T E R 3 METER 1 80 2 O T 8 1 R E T E M 5 1 2 M E T E R 3 METER 10 20 30 40 40 10 20 30 40 40 10 20 30 40 40 1 m 4 m 1 2 m 180 3 m Transverse detection area 12 m transversal to the detector Frontal detection area 4 m directly approa ching the detector Detection angle 180 ...

Page 10: ...p to the stop The motion detector now only reacts to movements independent of brightness Go diagonally to the detection area After the motion detector has detected a movement it switches on for 2 s Pay attention to the direction of motion during the test 0 2 Sec 2 sec Dusk Time Test mode 6 Alignment The sensor can be rotated to left right and down by 90 ...

Page 11: ...n by 60 90º 90º 90º 60º 45º Limiting the detection area using stickers Use the supplied stickers to adjust the motion detector to the desired detection area Remove the required section of the sticker by using scissors Then place on the lens Lens masking ...

Page 12: ...ronment lux level to turn On Adjustments Dusk Dawn Time Test mode Setting the brightness lux Turn the potentiometer to Moon the LED spot light only switches on when it is relatively dark Turn the potentiometer to Sun the LED spot light switches on when it is relatively bright Turn the potentiometer to Sun and the device works independent of brightness ...

Page 13: ... 10 min Manual operation The lighting can be manually switched on off via a circuit breaker button L L The surrounding brightness must be below the set value L L A circuit breaker button must be connected N L N L L Shortly press the circuit breaker button max 1 5 seconds ...

Page 14: ...y press the circuit breaker button max 1 5 seconds Setting the twilight switch function Turn the time potentiometer min clockwise up to the stop The twilight switch function is activated L L Now the motion detector does not respond to movements anymore L L The connected spotlight switches on at the set surrounding brightness CAUTION ...

Page 15: ...ss setting range 2 200 lx Duty cycle range 5 s 10 min Detection area transverse max 12 m frontal max 4 m 180 Installation height 2 5 m Sensor head can be rotated right left down by 90 90 Spotlight can be rotated up by 45 and down by 60 Energy efficiency class A theLeda BK A Switching contact μ contact Max switching capacity 1000 W 4 3 A at cos ϕ 1 Min switching capacity 10 mA 230 V Incandescent an...

Page 16: ...pact fluorescent lamps EB 80 W LED lamps 2 W 15 W LED lamps 2 8 W 50 W LED lamps 8 W 50 W 9 Contact Theben AG Hohenbergstraße 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 hotline theben de www theben de ...