ECHO PELLET E.I. 

Pellet Heater Owner's Manual 
Installation and Operating Instructions 

 

 
 

 
 
 
 
 
 
 
 

SAFETY NOTICE 

 

 

HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED OR A HOUSE FIRE MAY 
RESULT. 

 

FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS. 

 

CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION 
INSPECTION AND PERMIT. 

 

FAILURE TO COMPLY WITH OWNER'S MANUAL INSTRUCTIONS WILL VOID 
WARRANTY. 

PLEASE LEAVE THIS MANUAL WITH THE OWNER!! 

Warnock Hersey Test Labs, Middleton, WI 

Please read this entire manual before installation and use of the pellet fuel-burning room heater. Failure to follow these instructions 

could result in property damage, bodily injury or even death. 

 

Made in the USA by: 

 

 

 

12400 Loma Rica Drive, #5 

Grass Valley, CA 95945 

530-273-1976

 

Summary of Contents for ECHO PELLET E.I.

Page 1: ...STRICTIONS AND INSTALLATION INSPECTION AND PERMIT FAILURE TO COMPLY WITH OWNER S MANUAL INSTRUCTIONS WILL VOID WARRANTY PLEASE LEAVE THIS MANUAL WITH THE OWNER Warnock Hersey Test Labs Middleton WI Please read this entire manual before installation and use of the pellet fuel burning room heater Failure to follow these instructions could result in property damage bodily injury or even death Made in...

Page 2: ...see Figure 12 Clean one side at a time With covers removed leave the door open and push the Clean button Let heater run 30 seconds push to Off and replace cover Remove the remaining clean out cover and repeat procedure for other side c Vacuum inside stove ash pockets on both sides of fire pot and heat exchange tubes d Remove fire pot by lifting up and out It may be brushed out or vacuumed Fire pot...

Page 3: ...k power cord to see that it is plugged in tightly to the bottom of the stove Is the LED light blinking when you push the Low Medium or High button If not check the fuse for the igniter located on the bottom of the stove in the red fuse holder Remember that the timer on start up runs about six minutes and if the pellets have not lit then you may have to repeat the start up sequence Also the stove o...

Page 4: ...system for excessive ash and clogging particularly the vent cap Remove the clean out cap on the tee and make sure that ash has not blocked the exhaust air flow This automatic shut down in case of flue clogging is a safety feature and if the shut down occurs it means you have a problem and should consult a service technician and or clean your pipe and heater thoroughly If you feel the fly ash build...

Reviews: