PT59X
Room thermostat with the option to regulate domestic hot
water (DHW) and remote control by mobile telephone for
boilers with OpenTherm communication
- opening the main menu
-
ESC(escape)
=return one step back
- browse through the main menu (view)
- browse in the “
Parameters
” mode
- in the “
Setting program
” browse between time intervals
- browse (view) information by pressing ” “
-
ENTER= acknowledgement
= typing changes
- quick change of the requested temp.
(short-term in the mode “
Auto
”,
permanent in the “
Manual
” mode)
- change in the adjusted value
- Press the button “LCD” to select the appearance of the introductory display of information on the display
01.01.13
21:45
Thuesday
AUTO
prog:1
per.:1
IN:19.0°C DHW:50.0°C OT+
22.4
°
C
Temp. DHW: 57°C
OT+
Temp. DHW: 57°C
OT+
actual
IN:
22.4°C
UT:
42.0°C
OUT:
8.0°C
required
IN:
19.0°C
CH:
0.0°C
DHW:
50.0°C
Actual temp.
: 22.5°C
required IN
: 19.0°C
required DHW
: 50.0°C
outdoor:
8.0°C
- press “ “ for view following information ---------->>>>> by
TURNING
“ “ button next information
(about the heating system, the supply of hot service water, servicing, the outside temperature etc.)
- serves for fast copy of days in the “ Setting program” mode
- entrance/leaving into/from the service mode, press the button during about 5 s in the introductory display.
- Press the button to open the browse menu and the change the actual requested room temperature and the
automatic or manual mode
Turn the button “ “ to change the actual value of the requested temperature (in automatic mode up to the
further time section) or select another programme.
Turn the button “
“ to switch between the temperature and the programme
LCD
COPY
1
2
3
4
5
6
7
Control elements
Button function
- PRESSING
Button function
- TURNING
1
2
3
4
5
6
7
01.01.13
21:45
Thuesday
AUTO
prog:1
per.:1
01.01.13
21:45
Thuesday
AUTO
prog:1
per.:1
Required CH
= calculated
central heating
according
to he selected equitherm curve, according to the
weather) irrespective of min. and max, potential temper-
ature of CH, the data in brackets is the requested temp.
with respect to the adjusted min. and max. CH temper-
ature (see pages 6, 7 – constants No. 6 and 7)
Actual CH
= actual temperature of heating water
Modulation
= modulation output of the boiler in %
Flow
= information about the flow of DHW in litres per
minute for boiler
СХ
and
ТСХ
Required temp. DHW
= required DHW temperature
Operating hours CH and DHW
= reset by ”
LCD
”button
Temp. measured
= statistics value, reset by ”
LCD
”button
Works boiler inspector
= service telephone (see page 5)
Required temp. in AUTO/MANU mode
= change by
“ “, short-term in “Auto”, permanent in “Manual” mode
Outdoor temp.
= temperature on the outside temperature
sensor connected to the boiler
Required temp. in premature switching mode
=
constant No. 3
- Display backlight (after pressing any button the display is automatically backlit for about 2 s.)
LCD
COPY
DESCRIPTION
UT
sign for heating on
1
On the last line is further information, for example, the outside temperature
A)
B)
C)