EN - DE - IT
1
Battery Charger
© THI GmbH 2018/07
REF 60500 | Rev-02
BATTERY CHARGER
R
X
ONLY
INSTRUCTIONS FOR USE
LIMITATIONS OF USE
WARNINGS:
• Operation temperature for charger and power supply: -10 °C to +50 °C ( 14 °F to 122 °F)
• Upon delivery and before each use, inspect the charger and power adaptor to check
for any eventual damage. DO NOT use the devices if the cord and/or plug appear
damaged by the presence of cuts, holes or bent electrical contacts or cracks.
•
DO NOT expose the charger and power adaptor to heat, fi re, shock or high hu-
midity conditions that can generate condensation.
• DO NOT expose the charger and power adaptor to sources of heat or sunlight.
Place the battery charger in a cool place away from external heat sources.
•
DO NOT use this equipment in the presence of mixtures containing a fl ammable
anaesthetic substances including air, oxygen or nitrous oxide.
• Unless otherwise indicated, do not sterilize or immerse the charger or power
adaptor in water, solvents, lubricants or other cleansing chemicals, nor expose
them to them.
• DO NOT allow water to reach the charging bays on the top of the charger.
• DO NOT immerse water inside the power adaptor connector at the back of the
charger. Keep the device clean and dry.
• DO NOT short-circuit, crush, open, tear, incinerate, or disassemble the charger
or power adaptor.
• DO NOT modify or replace the power cord of the charger.
• DO NOT use any other power adaptor than the one included in the OXYGEN –
Battery Charger in combination with the charger.
• Use the battery charger and power adaptor only for the intended applications.
• When using medical equipment such as the charger and power adaptor, follow
the electromagnetic compatibility (CEM) procedures provided by the hospital.
• DO NOT use the charger by applying electrical voltages other than those indicat-
ed on the unit and in the instructions for use.
BATTERY CHARGING
For detailed charging instructions, consult the Instructions for Use of the
OXYGEN
and
ViVi
®
Helmet.
WARNINGS:
• Use this equipment to charge and to store REF 60401 Battery Pack only.
CLEANING
WARNINGS:
• DO NOT immerse the charger and power adaptor in liquids.
• DO NOT sterilize the charger and power adaptor.
CAUTIONS:
•
DO NOT use solvents, lubricants or other chemicals, unless otherwise specifi ed.
• DO NOT allow liquids or moisture into the electrical connections.
• DO NOT allow debris to enter electrical connections.
TO CLEAN THE BATTERY CHARGER
1. Unplug the charger from the power outlet.
2. Wipe the battery charger with a soft cloth dampened with a non-abrasive hos-
pital disinfectant. Follow applicable hospital protocol for cleaning.
3. Dry the equipment with a lint-free towel or medical-grade compressed air.
STORAGE AND TRANSPORT
Recommended storage and transport conditions: -20 °C to +60 °C (-4 °F to +140 °F),
up to 75 % relative humidity.
CAUTIONS:
• Carry or store the battery charger and power adaptor in low dust environments.
• DO NOT expose the battery charger and power adaptor to extreme temperature
changes.
DISPOSAL/RECYCLING
WARNINGS:
• ALWAYS follow the current local recommendations and/or regulations
governing environ-mental protection and risks associated with recycling
or disposing of the equipment at the end of its useful life.
• Per the European Union (EU) Waste Electronics and Electrical Equipment (WEEE)
Directive 2002/96/EC, product must be collected separately.
• DO NOT dispose of as unsorted municipal waste. Contact your local distributor
for disposal information.
• Contains no hazardous substances, per RoHS standard.
60500 BATTERY CHARGER
INSTRUCTIONS FOR USE - ENGLISH
IMPORTANT INFORMATION
The words
WARNING
,
CAUTION
, and
NOTE
have special meaning and should be
reviewed.
WARNING
A
WARNING
highlights a safety-related issue.
ALWAYS
comply with this information to prevent patient and/or
healthcare staff injury.
CAUTION
A
CAUTION
highlights a product reliability issue.
ALWAYS
comply with this information to prevent product damage.
NOTE
A
NOTE
supplements and/or clarifi es procedural information.
COMPLIANCE STATEMENTS
This battery charger REF 60500 has been tested and has met the requirements of
the following applicable regulations:
• EN 60601-1-2:2007
• FCC Title 47 CFR, Part 15, Class B/ IECS-003, IV edition
• ROHS Directive 2002/95/EC
INDICATIONS FOR USE
The Battery Charger REF 60500 is designed to recharge the battery pack REF 60401.
FOR USE WITH
REF 60401 Battery Pack.
SYMBOL DEFINITIONS
These symbols are located on the device and/or labels and are defi ned as follows:
SYMBOL
DEFINITION
Caution, consult accompanying documents
Waste Electrical and Electronic Equipment Directive (WEEE)
Recyclable Product
Direct Current (DC)
CE Mark
LOT
Serial Number
P/N
Catalog number
Manufacturer
TECHNICAL SPECIFICATION
MODEL
REF 60500
Description
Battery Charger
European Conformity
CE
Adaptor Input
100 – 240V (AC), 50-60 Hz, 1.7 A, 70W
Charger Input
24 V (DC), 2.9 A
Charging bays
4
Weight
• 390 g (13.8 oz) Battery Charger
• 375 g (13,3 oz) Power Adaptor
Dimensions
200 x 130 x 42 mm (7.87 x 5.12 x 1.65 in)
Ingress Protection (IP)
IPX0
Mode of operation
Continuous
ENGLISH (EN) - DEUTSCH (DE) - ITALIANO (IT)