Features:
⊙
Dual line 6 digits LED display
⊙
Optional dimension: 48W×48H
、
96W×48H
、
72W×72H
⊙
Can work with incremental rotary encoder, carry out up and down
counting.
⊙
One loop relay output.
⊙
Manual reset, auto reset, key lock function, power failure memory
function.
⊙
Settable counting coefficient, NPN or PNP input selectable.
⊙
Widely applied to the industries relevant to timber machining, food
machinery, packing machinery, steel machining, etc.
V. Connection Diagrams
1
IV. Dimension & Panel Cutout
Panel Size Side Size Cutout Size
CA4:(48×48)
CA7:(72×72)
CA8:(48×96)
48
72
96
Classification
Panel dimension
Panel cutout
A
H(Min)
G
B
C
D
E
F
J
48
72
48
97.5
97.5
97.5
6.5
9.0
9.0
91.0
88.5
88.5
45.5
67.5
92
25
25
25
45.5
67.5
45
45
67
44.5
K(Min)
25
25
25
Remark Unit
:
(mm) tol0.5% (unless there is special
specific illustration)
A
B
C
E
D
F
G
K
J
+0.5
-0
+0.5
-0
H
Note: If there is any change, please subject to the drawing on the meter.
CA8
CA4
10
9
8
7
6
+12V
AC/DC
100~240V
OUT
INB
INA
RST GND
4
5
3
2
1
CA7
AC/DC
100~240V
OUT
INA
INB +12V
RESET INHIBIT
GND
2
1
3
4
5
6
14
13
17
18
19
OUT
AC/DC
100~240V
INHIBIT RESET GND
INA
INB
+12V
2
1
3
9
10
15
16
17
18
19
20
II. Technical Parameter
AC/DC 100
~
240V 50/60Hz
≤4W
AC 250V/3A
DC 12V±5V(≤25mA)
≥20MΩ
AC 2kV
Power:3000Vp-p
、
I/0 terminal:1000Vp-p
Power Supply
Total Power Consumption
Relay Capacity
Output Power
Insulation Resistance
Insulation Strength
Anti-interference
Input Signal (sine wave,
square wave)
Counting Input Speed
Counting Range
Delay Time
Coefficient Setting Range
External Signal
Signal Level: Hight:3~30V Low:0~2V
≤1/30/300/5000Hz (4 speed
selectable)
-199999~999999
0.01~499.99s
0.00001~999999
External reset frequency
1
、
20ms selectable
CA-X Series Digital Counter
KKCAX-A01C-20180120
Digital Counter
CA-X
series
Thank you for purchasing TOKY products. Please
read the instruction manual carefully before using this
product, and use the product correctly. Also, please keep
this instruction manual where you can view it any time.
TOKY ELECTRICAL CO., LTD.
No.8, Minke West Road, Shiqi District,
Zhongshan City,
Guangdong Province,
China
TEL: +86-760-23371807
http://www.toky.com.cn
INSTRUCTION MANUAL
Note: If there is no operation for long time, meter will automatically
return back to measuring state (set parameter is not saved.)
SET
(1) Menu key: press it 3 sec to enter or exit setup mode
.
(2) Confirm key: confirm and save the modified set value.
Up key
RST
Reset key
In modification state, press it to increase set value.
(1) In operation mode or setup mode, press it to
activate the set value modification.
(2) In modification state, press it to move set
value row.
In operation mode, press it to reset PV.
Name Content
Shift key
Set key
III. Panel Illustration
5
SET
RST
OUT
SV
PV
PRESENT VALUE
(1) Display present value in
operation mode
(2) Display parameter code
in setup mode
Operation indicator
OUT: Turns on
during output
operation
SET VALUE
(1) Display set value in
operation mode
(2) Display parameter set
value in setup mode
UP
RESET
SET
SHIFT
Communication
Display digits
Version
0
6
8
X-
A
Size
6 digits display
No communication
RS485 communication
Version A
Alarm
RB
1 relay output
F
AC/DC 24V
Power
voltage
-
AC/DC 100~240V
8
96(W) X 48(H) X 88.5(D) mm
7
72(W) X 72(H) X 88.5(D) mm
I. Suffix Code
Code
Content
CA
4
Model
□ □
-
□
CA-X series digital counter
48(W) X 48(H) X 91(D) mm
X-
□
□ □