Direct Cooling Type   

Deli  /  Bakery  Cases  Installation  and 

Operation Manual

 

         

  Please read this manual completely before attempting to install or operate this equipment   
 
 

 

 

 

   

 

DZW-1200    DZW-1500    DZW-1800      DZW-2000 

 

 

Summary of Contents for DZW-1200

Page 1: ...1 Direct Cooling Type Deli Bakery Cases Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment DZW 1200 DZW 1500 DZW 1800 DZW 2000...

Page 2: ...2 TABLE OF CONTENTS Section Page Warning 3 4 Technical Specification 4 Installation 4 5 Operation 5 8 Maintenance 8 9 Parts Breakdown 8 12 Electrical Diagram 12...

Page 3: ...N GU A DEL PROPIETARIO ANTES DE INTENTAR DAR SERVICIO A ESTE PRODUCTO DEBEN CUMPLIR CON TODAS LAS PRECAUCIONES DE SEGURIDAD ATTENTION RISQUE DE FEU OU D EXPLOSION LE FRIGORIG NE EST INFLAMMABLE CONSU...

Page 4: ...HP 1 3 1 3 1 2 1 2 Electrical 110V 60HZ 1P Amps 5 0 5 8 6 2 6 8 Temperature Range 33 41 F Refrigerant R290a Dimensions 47 2 x32 5 x45 2 59 x32 5 x45 2 70 8 x32 5 x45 2 79 x32 5 x45 2 Shipping Weight 5...

Page 5: ...ress the brake on the wheels to keep it from moving 5 Fix the shelves on the unit ELECTRICAL CONNECTION Before inserting the plug into the electrical socket carefully read the following precautions 1...

Page 6: ...on the thermostat 5 If there is some condensation in front of the curved glass please turn the switch to I position for defogging 6 Allow the unit to reach proper temperature before loading with produ...

Page 7: ...displayed and the C or F LED starts blinking 3 To change the Set value push the or arrows within 10s 4 To memorise the new set point value push the SET key again or wait 10s 3 How to start a manual de...

Page 8: ...a high standard of working performance leave the unit turned on during the night and day to avoid deposits CAUTION Do not use any damaging solvents petrol alcohol etc for cleaning the unit The unit ma...

Page 9: ...Troubleshooting System Possible Reasons Solution Remark No power input power direction Broken fuse Replace As for authorized service department Poor connection of plug and Repair or replace the socke...

Page 10: ...Repair or replace Compressor runs but the temperature in the showcase is high Circulating temperature is too high Adjust the thermostat properly Ask for authorized service department to check and too...

Page 11: ...11...

Page 12: ...X 0 11 AIR GUIDE BOARD 12 Front glass 138 0012 DZX 0 12 FRONT GLASS 13 Front panel 138 0013 DZX 0 13 FRONT PANEL 14 Condenser 138 0014 DZX 0 14 CONDENSER 15 Compressor board 138 0015 DZX 0 15 COMPRESS...

Page 13: ...13 CIRCUIT DIAGRAM...