background image

Instruction Manual

Thermal Imaging Camera

Summary of Contents for ET692B

Page 1: ...Instruction Manual Thermal Imaging Camera ...

Page 2: ...duction to image sub menu 2 1 View image 2 2 Delete images 3 Introduction to Video submenu 3 1 View video 24 25 26 27 28 29 29 31 29 29 30 32 30 25 22 23 23 29 35 3 2 Delete video 4 Introduction to color palette sub menu 4 1 Color palette description 4 2 Application of color palette 5 Introduction to emissivity sub menu 5 1 Emissivity description 5 2 Emissivity setting 5 3 The emissivity value of ...

Page 3: ...r return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transportation expenses paid by the purchasers If the product failure is verified by neglige...

Page 4: ...de in order not to damage the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such...

Page 5: ...sion and other serious consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product i...

Page 6: ...nsation inside please power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire con...

Page 7: ... professional optical lens cleaners Lens maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest a...

Page 8: ...t of the screen will display Please charge in time through Micro USB interface When the product is off you can charge 11 12 Rainbow iron oxide red cold color black white white black IFOV Field angle Infrared detector type Focus mode Temperature measurement range Measurement accuracy Temperature measurement resolution Temperature measurement mode Vanadium Oxide Uncooled Infrared Focal Plane 3 75mra...

Page 9: ...available storage space is about 3G JPG MP4 USB connection to computer export Lighting system LED fill light Battery Type Battery capacity Working time Removable Rechargeable Lithium Battery 18650 2200mAh 2 to 3 hours Power interface Micro USB Power configuration 5 minutes 20 minutes no automatic shutdown Work temperature 10 to 50 Storage temperature 20 to 60 Relative humidity 10 to 85 RH non cond...

Page 10: ...creen Battery Micro USB Please open the cap in use 2 15 16 The highest temperature cursor used to indicate the highest temperature position in the screen area It will move with the movement of the highest temperature The cursor displays red The temperature value is displayed at bottom left corner of the screen Maximum value minimum value of field temperature Color code Current emissivity Battery p...

Page 11: ...ments with widely varying ambient temperatures Image capture press the image capture key When the capture is successful the screen will display store photo prompt If yes is selected please press MENU key to determine to save the image If no is selected press SELECT ENTER key to determine not to save the image 17 18 3 Key description Menu key On off key Navigation key Up down left and right Selecti...

Page 12: ...exit the image blending mode Note If there is no operation for more than 6 seconds the image blending mode will be automatically exited The function to hide highest lowest temperature column at the screen bottom under the operation after normal start up press key and the screen bottom will display highest lowest temperature column Press can also hide it Image output The saved images through captur...

Page 13: ...21 22 20220210 175305 20220210 174633 20220210 174635 20220210 174334 3 Introduction to Video submenu 3 1 View video Press MENU key to enter the main menu select in the main menu video as shown below 20220211 154307 20220211 124307 20220210 174307 20220210 164307 3 2 Delete video Press the key to enter the video list press the and keys in the navigation keys to select the video and then press the ...

Page 14: ...y Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best with high thermal contrast and provide additional color contrast between high and low temperatures Suitable selection of color palette displays the details of the target objective better Rainbow iro...

Page 15: ...ects that give out less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement The surface emissivit...

Page 16: ... to be changed press keys to change the value After themodification is completed press SELECT ENTER to confirm then press to return The MENU button exits the menu 27 28 6 Introduction to setting sub menu Press MENU key to select the setting option in the main menu Press key again to enter the setting sub menu Settings Auto shutdown Auto shutdown Intensity Language Unit Time Format Year Month Day H...

Page 17: ...s As shown in the figure after selecting set time press in the navigation key to enter the setting time After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 6 3 Language settings After selecting language press the button in the navigation key to enter the language setting Available in 4 languages English Chinese Ita...

Page 18: ...ine selection After the setting is completed press key to return Press MENU key to exit from the menu 31 32 Spot Off On Thermal Imaging Image Analysis Software Operation Guide 1 Connect the product with a USB cable and then connect to the computer Open the removable disk in the computer find the INSTALLATION PACKAGE folder and open it and click to install the software Software Installation And Ope...

Page 19: ...re unit In the temperature unit click the icon to select three temperature units Celsius Fahrenheit and Kelvin Picture information display file name emissivity capture time maximum temperature minimum temperature center point temperature original thermal image Interface Introduction Icon Introduction 1 icon take the temperature of the thermal image 2 icon select the maximum temperature and minimum...

Page 20: ...on The thermal imaging device cannot start The thermal imaging device powers off automatically Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new battery or charge it The power of the battery is used up Replace with new battery or charge it The time set for automatic power off is due Restart or change the time for automatic ...

Reviews: