background image

FC-120

ESC

Alt

INSTRUCTION MANUAL

DATA COLLECTOR

FC-120

64855 90012

SERIES

FC-120

Summary of Contents for FC-120 Series

Page 1: ...FC 120 ESC Alt INSTRUCTION MANUAL DATA COLLECTOR FC 120 64855 90012 SERIES FC 120...

Page 2: ......

Page 3: ...be sure to check that the instrument is functioning correctly with normal performance Always make sure instrument is dry before putting it in the soft case Never store a damp instrument Do not leave...

Page 4: ...end that you become familiar with the meaning of these Warnings and Cautions before continuing Injury refers to hurt burn electric shock etc Physical damage refers to extensive damage to equipment and...

Page 5: ...injury Do not dispose in fire or heat To reduce the risk of hazards use only CSA UL certified power supply cord set cord is Type SPT 2 or heavier minimum No 18 AWG copper one end is provided with a m...

Page 6: ...ty or intentional usage or misuse including any direct indirect consequential damage and loss of profits 3 The manufacturer or its representatives assumes no responsibility for consequential damage an...

Page 7: ...ty 4 Contents 5 Standard Package Components 7 Nomenclature 8 FC 120 8 Connectors 10 Preparation for Use 11 Shortcut Keys 11 Battery 12 Setting Handstrap 16 Touch Screen 17 How to Insert CF Card 18 Tra...

Page 8: ...6 Set the Automatic Backup for every suspension 22 Set the restoration after hard reset 22 Resetting FC 120 23 Soft Reset 23 Hard Reset 24 Specifications 25 Storage Precautions 28...

Page 9: ...ngs are included 1 FC 120 Instrument 1set 2 BT 66Q Battery 1pc 3 AC DC converter AD 13 1pc 4 Interface cable F 25 1pc 5 Handstrap 1pc 6 Soft case 1pc 7 Stylus pen 1pc 8 Display protection sheet 2pcs 9...

Page 10: ...y FC 120 Card slot cap Speaker Charge LED Escape key Alt key Home key Cursor keys Connector caps Microphone Power key Windows key Stylus pen Hook for tripod Hook for handstrap Battery cover Cover scre...

Page 11: ...ject the CF card stand the button up then press it CF slot SD slot Hard reset switch USB Connector Mini B Serial Connector Card slot side Connector side This figure shows the FC 120 with the cap opene...

Page 12: ...Connectors No 1 DCD IN No 2 RXD IN No 3 TXD OUT No 4 DTR OUT No 5 GND No 6 DSR IN No 7 RTS OUT No 8 CTS IN No 9 RI IN Serial connector USB Connector Type Mini B No 1 VDD No 2 V No 3 V No 4 NC No 5 GN...

Page 13: ...paration for Use Shortcut Keys Shortcut Commands OR are the same as a right click on a mouse A menu is displayed containing commands specific to the item Continue tapping on an item Press Alt tap on a...

Page 14: ...a coin loosen the cover screw on the battery cover 2 Remove the battery cover 3 Install the battery pack Confirm the direction of battery installation 4 Using a coin install the battery cover Tighten...

Page 15: ...mpleted after approximately 6 hours The display can be turned on or off by the power key The charge LED of FC 120 will indicate charging status Red ON Charging Green ON Charging completed Red Flashing...

Page 16: ...e in a place at 30 C or below If you allow the battery to be completely discharged it will have an effect on the proper charging in the future 4 The charger may develop heat while charging This is not...

Page 17: ...e adjusted by the following procedure 1 Press Alt tap the background of Desktop Properties Backlight 2 Adjust by or icon of Brightness setting Low temperature use Battery capacity is reduced at low te...

Page 18: ...16 Setting Handstrap 1 Set the handstrap on the handstrap hook c 2 Set the handstrap on the handstrap hook d Handstrap...

Page 19: ...Setting Control Panel Stylus Calibration Recalibrate 2 Using a stylus pen touch the center of the target 3 After touching all targets 5 points press ENT key or tap the display Use an accessory stylus...

Page 20: ...serting into the card slot If you forcibly insert the card incorrectly the pin at the card slot may be damaged and cause a breakdown Please insert straight down into the card slot If you forcibly inse...

Page 21: ...as shown below 3 The FC 120 will give the prompt Connecting to Host 4 The PC will prompt you to set up a partnership or set up as a guest 5 Select the NO key to setting up as a guest 6 Press the Next...

Page 22: ...built in Information can be exchanged between instruments equipped with the same function using wireless 1 Regarding the Bluetooth setting please see the instruction manual BTManager 2 0 1 Serial Por...

Page 23: ...dditionally installed programs into named Backup folder in the Storage Card Execute the Backup function 1 Tap the icon Start Settings Control Panel System Backup You can see the Backup screen on Displ...

Page 24: ...tory setting is ON as default 2 Tap the button OK on title bar After that Backup screen will close automatically Set the restoration after hard reset 1 On the Backup Screen check it ON OFF the Data re...

Page 25: ...ods to reset the FC 120 Soft Reset With the soft reset all running applications will be shutdown and data you are editing will be lost however installed programs and stored data are protected How to s...

Page 26: ...defaults and erase all RAM data How to hard reset 1 Remove all cables or cards CFs SDs that are currently mounted 2 Lightly press the hard reset switch beside the AC DC converter connector with stylus...

Page 27: ...56MB Flash ROM Display Display resolution 240 320 QVGA Type 3 5 inch TFT Color LCD Light LED back light Touch panel Analog resistive film Keyboard 10 keys Power key included LED 1 LED charge Interface...

Page 28: ...e IP66 2 Operation temperature 20 C to 50 C 4 F to 122 F Storage temperature 30 C to 60 C 22 F to 140 F Shock resistance Dropping this instrument from a height of 1 meter does not affect its functions...

Page 29: ...acklight room temperature and application software used When Bluetooth is used battery capacity will lower approximately 30 Battery BT 66Q Type Lithium ion battery Regular voltage 7 4V Nominal capacit...

Page 30: ...es Microsoft Windows CE and ActiveSync are registered trademarks of US Microsoft in the U S A and other countries Always clean the instrument after use 1 If the instrument becomes wet from rain dry mo...

Page 31: ...ned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if...

Page 32: ...10 EN 301 489 17 V1 2 1 2002 08 EN 301 489 1 V1 6 1 2005 09 EN 55022 2006 Class A EN 61000 3 2 2000 A2 2005 EN 61000 3 3 1995 A1 2001 Hereby TOPCON CORP declare that this DATA COLLECTOR FC 120 is in...

Page 33: ...2008 TOPCON CORPORATION ALL RIGHTS RESERVED...

Page 34: ...Cedex France Krungdhonburi Rd Klongtonsai Klongsarn Bangkok 10600 Thailand Taman Ampang Hilir 55100 Kuala Lumpur MALAYSIA Phone 60 3 42701192 Fax 60 3 42704508 P O Box293705 Office C 25 row C 2 Dubai...

Reviews: