PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

2

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2— Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

2

. . . . . . . . . . . . . . . . .

Step 4 — Thermostat Operation

3

. . . . . . . . . . . . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

3

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified

installer or agency muse use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local

building codes and the current editions of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in the instructions or

manuals, be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies a hazard

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

INTRODUCTION

The Base thermostat is an electronic 24VAC, non--programmable,
manual changeover wall mount thermostat. This thermostat uses a

single setpoint to maintain and control room temperature in both
the heating and air conditioning modes. The thermostat is designed

to ma/-- 2

_

F accuracy. No batteries are required;

temperature, fan, mode, and installer configuration settings are
preserved with power off.

INSTALLATION CONSIDERATIONS

Universal Model

The P700U--21NHP Base thermostat may be configured for either
AC models or HP models. When configured as an AC model, it

may be wired with or without connecting a common wire between
the indoor equipment and the thermostat. However, it is

recommended to use a common wire whenever possible. Without a

common wire this thermostat becomes “power stealing.” This
means it will need to steal a small amount of power from the

equipment to which it is connected.

NOTE

: Not all HVAC equipment is compatible with power

stealing type thermostats. All Carrier equipment is directly
compatible with this thermostat except the Thermostat Conversion
Kit, Part #TSTATXXCNV10. For all non--Carrier equipment,
consult the system equipment Installation Instructions before
applying this thermostat in a power stealing manner.
When configured for HP units, it is NOT power stealing and

MUST have both the R and C terminals connected to operate

properly. This thermostat uses a green LED to indicate auxiliary
heat and emergency heat operation.

Summary of Contents for P700U-21NHP

Page 1: ...NG and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which wil...

Page 2: ...r conditioner model 1 stage heat 1 stage cool or HP or PH for heat pump model 2 stage heat 1 stage cool Step 3 Set Thermostat Configuration Configuration options allow the installer to configure the thermostat for a particular installation These selections are intended to be made at installation and normally are not modified by the homeowner Below is a list of available options followed by a descr...

Page 3: ... the output is turned on e g if Y output is turned on for 9 minutes and then satisfies it cannot turn back on for another 6 minutes regardless of demand However pressing UP and FAN buttons simultaneously or changing the setpoint will override the timer for 1 cycle Minimum on Timer Once the equipment has turned on it will remain on for a minimum of 3 minutes regardless of demand However the equipme...

Page 4: ...HP Thermostat Typical Installation Replacement Components Carrier Corporation www totaline com Edition Date 01 14 EAR99 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No RCIIP700U 21NHP 01 Replaces NEW ...

Page 5: ...after the last button press the display returns to the room temperature and the SET TEMP icon turns off TROUBLESHOOTING What if there is a green light on in the upper corner of the display area This thermostat uses a green LED to indicate auxiliary heat and emergency heat operation on the Heat Pump model This green light means one of two things 1 Auxiliary Heat is on This light turns on automatica...

Page 6: ...2 ...

Page 7: ...WANCE OR OTHER COSTS incurred for diagnosis repairing removing installing shipping servicing or handling of either defective parts or replacement parts SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY ...

Page 8: ... Carrier Corporation www totaline com Edition Date 01 14 EAR99 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No RCIIP700U 21NHP 01 Replaces NEW ...

Reviews: