background image

100' Cross-Line

Laser Level

TB-H2-LL-100-L2

OPERATING / SAFETY INSTRUCTIONS

IMPORTANT! Read all safety warnings and instructions before using.

ToughBuilt Industries, Inc.

6671 S. Las Vegas Blvd.

Building D, Suite 210

Las Vegas, NV 89119 USA

Made in China

TB-H2-LL-100-L2.EN.v2  Date: 2022-09-14

Summary of Contents for TB-H2-LL-100-L2

Page 1: ...2 OPERATING SAFETY INSTRUCTIONS IMPORTANT Read all safety warnings and instructions before using ToughBuilt Industries Inc 6671 S Las Vegas Blvd Building D Suite 210 Las Vegas NV 89119 USA Made in Chi...

Page 2: ...g Function 9 QuickSet Rotating Mount and Ceiling Bracket 9 Using QuickSet Rotating Mount 10 Using Ceiling Bracket 12 Working with the Laser Target Plate 12 4 ACCURACY CHECK 13 5 TROUBLESHOOTING 20 6 C...

Page 3: ...isassemble or modify the device Tampering with this device may result in hazardous laser radiation exposure and will automatically void all warranties DO NOT leave the device turned on when unattended...

Page 4: ...NOT mix battery chemistries DO NOT short battery terminal ALWAYS check battery posts in the battery compartment for corrosion Clean the posts before use DO NOT use batteries with corroded terminals D...

Page 5: ...oss Lines Working Range Up to 100 30 5m Laser Beam Color Green Laser Type Emission Wave Length of 510 530 nm Class 2 1 mW Accuracy 1 8 33 3 18mm 10 1m Self Leveling Range 4 degrees Operating Temperatu...

Page 6: ...t first DO NOT turn on a wet or damp instrument To wipe the Laser Beam Window 1 use ONLY a lint free cloth DO NOT USE A PAPER TOWEL PLEASE NOTE Laser beam expands as the distance between the instrumen...

Page 7: ...selected both in the Self Levelling Mode and in the Pendulum Locked Mode QuickSet Rotating Mount and Ceiling Bracket The QuickSet Rotating Mount and Ceiling Bracket allow mounting the laser instrumen...

Page 8: ...een the magnetic surfaces Working with the Laser Target Plate The Laser Target Plate 14 improves the visibility of the laser beam under unfavorable light conditions and at long distances within the wo...

Page 9: ...k procedure is conducted must be sufficiently level so that the instrument remains within the self leveling range of 4 from the 0 level position Step 1 Checking the Height Accuracy of the Horizontal L...

Page 10: ...responding Distance Between Walls in the table below the instrument must be serviced Step 2 Checking the Leveling Accuracy of the Horizontal Line For this check a 16 5m or 30 9m distance to the opposi...

Page 11: ...f the door opening point a at an 8 2 5m distance beyond the other side of the door opening point b and at the upper edge of the door opening point c1 4 Swivel the instrument 45 to the right to positio...

Page 12: ...Cannot Power OFF Pendulum Switch 2 is in the UNLOCK position Slide the Pendulum Switch 2 to the LOCK position then press the Power ON OFF button 5 Out of Level Laser Beam Laser Beam out of leveling ca...

Page 13: ...sed of with household waste Please sort it out for separate recycling Separate collection of used products and packaging allows materials to be recycled and used again Reuse of recycled materials help...

Page 14: ...23 24...