background image

 

FIG. 1 FLUSH MOUNT

 

FIG. 2 SURFACE MOUNT

  

 14 1/4

     (362 mm)

  

19 3/16

    (490.5mm)

8” (203.2)Minimum
To  Finished Floor

8” (203.2)Minimum
To  Finished Floor

SERVICE CABLE
OR CONDUIT

AFA

3320 SERIES

IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSTALLATION

 INSTRUCTIONS

Form 9822           ECO # 1-5800

4. WIRING INSTRUCTIONS REF:  WD1, WD2, WD3, WD4, WD5, WD6

A. Bring service leads through knockout “K” on top or bottom of rough-
     in box for flush or semi-recessed mounting, bottom knockout “K”

only for surface mounting. When wiring from the bottom, install wire

     through cover “G” by removing screw “H”.
B. Attach service leads to two black leads on 208-240 volt models and

to black and white leads on 120-277 volt models, attach ground lead

     to green wire with approved connectors. Comply with all national

and local codes.

C. Attach wiring compartment cover “D” to assembly with screw “C”.

5. FINAL STEPS:

A. Clean all construction dirt and debris from inside heater.
B. Attach front grille “F” with four screws “L”.
C. Place grille frame over tabs on top of grille, snap bottom in place.

For added security install screw “Q” into bottom of frame.

6. OPERATING INSTRUCTIONS:

A. Turn on power at the circuit breaker panel.
B. Thermostat adjustment is made by inserting a small blade screw
     driver through grille opening into slot in stem. Turn thermostat
     adjustment stem fully clockwise, this will energize the heating
     element and after a short delay, the fan should energize, causing
     warm air discharge from bottom of the grille.
C. After the desired temperature is reached, turn thermostat stem

counter clockwise until a click is heard from the thermostat.

D. Models with double-pole thermostats: Turn thermostat adjustment
     stem fully counter-clockwise, this will de-energize the heating
     element and fan.

1. LOCATION OF HEATER:

A. Heater is mounted on the wall near ceiling or floor, air flow down.

CAUTION: 

Do not obstruct the front grille of the heater with

curtains, furniture, etc., since the proper operation of the heater
requires a free flow intake and exhaust of air.

B. Minimum mounting height is 8” above finished floor.
C. For surface mounting use adapter AFAA/3320EX33.
D. For semi-recessed mounting, use adaptor AFAA-2/3320EX16.

2. BEFORE MOUNTING:

A. Insure that the supply voltage matches voltage rating on the label of
     the heater.
B. Turn off electrical power to heater circuit.

3. MOUNTING INSTRUCTIONS:

A. Disassemble heater by removing 7 screws “C” as shown in Figure

1 and 2.

B. Flush mounting, see Fig. 1.

Place rough-in box “A” between studs at desired height: secure to
studs through holes “M”. The flanges on the rough-in box must rest
on the surface of the finished wall; if the box is installed prior to the
application of the finished wall, allowance must be made for the wall

     thickness.
C. Surface mounting, See Fig. 1.

Insert rough-in box “A” into surface adapter “E”. Secure the heater
rough-in box to wall at desired height through holes “X”. Be sure
 that the rough in box is centered in surface adapter. For surface
mounting, bring wiring through bottom knockout “K” only.

D. Semi-recessed mounting: Secure rough-in box so that the long
     flanges extend away from the finished wall equal to the depth of the
     adaptor. Bring service in through top or bottom knockout “K”.
E.  Place assembly “B” into rough-in box “A”. Secure with six
      screws “C”.

Wall Installation

7. CLEANING AND MAINTENANCE INSTRUCTIONS:

A. At the beginning of each heating season, disconnect electrical

power at circuit breaker panel. Remove front grille.

B. Use the narrow (crevice” suction attachment of the vacuum

cleaner to remove dust and lint from heater and heating element.

C. Lubricate the motor with SAE No. 10 oil. Two (2) oil spouts are

located on front and back of motor.

D. Reinstall front grille with previously removed screws. Restore

power to the heater.

   

FIG. 1 FLUSH MOUNT

   

FIG. 2 SURFACE MOUNT

Note: This heater employs a visual alarm (light) to warn that parts of the
heater are getting excessively hot. If the alarm illuminates,  immediately
disconnect power from heater and inspect for any objects on or
adjacent to the heater that may cause high temperatures. DO NOT
OPERATE HEATER WITH THE ALARM (LIGHT) ILLUMINATED.

Reviews: