SPECIFICATIONS 

Range: 

–76° to 932°F / –60° to 500°C 

Resolution: 

0.1° (–9.9° to 199.9°) 1° (otherwise) 

 

OPERATION 

Press and continue to hold down the trigger to take temperature readings. The 

unit will take temperature readings while the trigger is pressed and held (SCAN 

appearing on the display indicates measurements are being taken).  
After the trigger is released, the last temperature measured will be displayed for 

approximately 60 seconds, the display will then turn off automatically. HOLD will 

appear on the display when the trigger has been released to indicate that the 

unit is no longer taking temperature measurements. 

 

SELECTING UNITS OF MEASURE 

Press and release the trigger to turn on the display. Once the display is on (and 

the trigger has been released), each press of the °C/°F button will toggle 

between °C and °F. 

(If the trigger is being held when the °C/°F button is 

pressed, this will laser targeting on/off.) 

 

LASER TARGETING 

While pressing and holding the trigger, each press the °C/°F button toggles 

laser targeting on and off. With laser targeting on, each time the trigger is 

pressed and held, the laser beam will be emitted. 

 

CAUTION:

 Eye damage may result from direct exposure to laser light. 

 

DISTANCE SPOT/RATIO 

There are other factors that may affect measurement accuracy. The target must 

completely fill the spot diameter seen by the infrared sensor; otherwise readings 

will be influenced by the surface surrounding the target. The ratio of the distance 

to the size of the spot being measured is 12:1. For example, an object’s 

diameter of 100mm can be measured from 1100mm. 

 

BACKLIGHT 

While pressing and holding the trigger, each press the LOCK button toggles the 

LCD backlight on and off. With the backlight on, each time the trigger is pressed 

and held, the LCD will be illuminated by the backlight. 

 

VALUES RECORDED 

With each press of the trigger, five values are recorded: 

1. 

MAX

 – Highest temperature measured. 

2. 

MIN

 – Lowest temperature measured. 

3. 

dIF

 – Difference between MAX and MIN. 

4. 

AVG

 – Time-weighted average temperature. 

5.  The value last displayed before releasing the trigger. (Appears at the bottom 

of the display.) 

 

DISPLAY MODES 

Each press of the MODE button will select one of the 8 display modes. You can 

cycle through the modes in this order: 

“E”

 – Emissivity value display (See the Emissivity section). 

“MAX”

 (Maximum temperature) – Press the MODE button until 

MAX

 appears 

on the display. In the 

MAX

 mode, the highest temperature measurement taken 

is displayed to the right of 

MAX

. This value will update each time a higher 

temperature is measured. 

“MIN”

 (Minimum temperature) - Press the MODE button until 

MIN

 appears 

on the display. In 

MIN

 mode, the lowest temperature measurement taken is 

displayed to the right of MIN. This value will update each time a new lower 

temperature is measured.  

“dIF”

 (Temperature differential between 

MAX

 and 

MIN

) – Press the MODE 

button until 

dIF

 appears on the display. The difference between the MAX and 

MIN reading is displayed to the right of 

dIF

. This value is updated as new MAX 

and MIN temperatures are measured. 

“AVG”

 (Calculated (time weighted) average temperature] – Press the MODE 

button until 

AVG

 appears on the display. The time weighted average 

temperature reading is displayed to the right of 

AVG

. This value is updated 

continuously while the trigger is being pressed. 
The term “time”, in reference to the averaging mode, means all temperature 

measurements are averaged together from the first press of the trigger.  

 
 
 

Example: If the temperature was 72° for one minute, then 20° for ½ second, no 

significant change in average temperature would be displayed. 

“HAL”

 (High Temperature Alarm) – Press the MODE button until 

HAL

 

appears on the display. The high temperature alarm value that has been set is 

displayed to the left of 

HAL

. (See High/Low Alarms section.) 

“LAL”

 (Low Temperature Alarm) – Press the MODE button until 

LAL

 

appears on the display. The low temperature alarm value that has been set is 

displayed to the left of 

LAL

. (See High/Low Alarms section.) 

“PRB”

 (Probe Temperature) – Press the MODE button until 

PRB

 appears 

on the display. The external probe temperature is displayed to the left of 

PRB

If no probe is connected,

 noP

 will appear to the right of 

PRB

.  

 

With a probe connected, the unit will display the probe temperature without 

pressing the trigger. While in PRB mode, the unit will turn off automatically after 

12 minutes if no buttons are pressed. 

Only Type-K thermocouple probes may 

be used with this unit. 

 

NOTE: The last mode selected will remain selected the next time the trigger is 

pressed. 

 

MEMORY RECALL 

With each press of the trigger, five values are recorded: 

1. 

MAX

 – Highest temperature measured. 

2. 

MIN

 – Lowest temperature measured. 

3. 

dIF

 – Difference between MAX and MIN. 

4. 

AVG

 – Time-weighted average temperature. 

5.  The value last displayed before releasing the trigger. 

 

To cycle through each of the values recorded during the last measurement, 

press the MODE button. (See the “Display Modes” section for an explanation of 

the values displayed.) 

 

HI/LOW Alarms 

An audible alarm will sound at both an upper and a lower temperature limit. To 

adjust the alarm temperature set points: 

1.  Press the MODE button until 

“HAL”

 (High Temperature Alarm) or 

“LAL”

 (Low Temperature Alarm) is displayed.   

2.  To adjust the temperature alarm set point, press the ↑ or ↓ button. 

(Do not 

press the trigger while adjusting the alarm set points). 

Press and hold to 

advance the display rapidly. 

3.  Once the desired temperature alarm set point appears on the display, press 

the trigger to confirm the value.  

 

While taking temperature measurements, an alarm will sound when the 

temperature measured is above or below High and Low alarm set points that 

have been entered. If the temperature is above the High Alarm set point, (((HI))) 

will appear at the top right corner of the display. If the temperature is below the 

Low Alarm set point, (((LO))) will appear at the top right corner of the display. 

 

The alarm will sound regardless of the Display Mode if the temperature 

measured is above or below High and Low alarm set points that have been 

entered. 

 

LOCK FUNCTION 

The lock function allows the thermometer to take measurements without having 

to press and hold the trigger. When the lock function is activated, the unit will 

take continuous temperature measurements for 60 minutes and will then turn off 

automatically to preserve battery life. 

 

To activate the lock mode, while in the 

E

MAX

MIN

dIF

, or 

AVG

 mode, 

press the LOCK button. LOCK and SCAN will appear on the display to indicate 

that the unit is in the lock mode and is taking measurements. 

(Do not press and 

hold the trigger while activating the lock mode.) 

 

To deactivate the lock mode, while in the 

E

MAX

MIN

dIF

, or 

AVG

 

mode, press the LOCK button. 

HOLD

 will appear on the display to indicate 

that the unit is no longer taking measurements. 

(Do not press and hold the 

trigger while deactivating the lock mode.) 

 

 

 

TRACEABLE® INFRARED THERMOMETER WITH TRIGGER GRIP INSTRUCTIONS 

www.

GlobalTestSupply

.com

Find Quality Products Online at: