background image

R. Stahl Tranberg AS 

stahl-tranberg.com
Main office: Strandsvingen 6

 | 

N-4032 Stavanger

 | 

Norway 

T

 

+47 51 57 89 00

 |

 

E

 

info.no-st@r-stahl.com

Office Oslo: Luhrtoppen 2

 | 

N-1470 Lørenskog

 

|

 Norway 

T

 +47 24 08 44 10 

|

 

E

 

info.no-os@r-stahl.com

IMPORTANT

Read this instruction carefully before installing the 
product

LIGHTING 

BLUELINE 

TEF 2580 LED FLOODLIGHT

SAFE AREA

USER MANUAL

Subject to change without prior notice  

TUM6650  REV A. 06.10.2020

Summary of Contents for BLUELINE TEF 2580 LED

Page 1: ...nfo no st r stahl com Office Oslo Luhrtoppen 2 N 1470 Lørenskog Norway T 47 24 08 44 10 E info no os r stahl com IMPORTANT Read this instruction carefully before installing the product LIGHTING BLUELINE TEF 2580 LED FLOODLIGHT SAFE AREA USER MANUAL Subject to change without prior notice TUM6650 REV A 06 10 2020 ...

Page 2: ...check for water intru sion in the housing When cleaning use only mild detergents Alcohol or petro leum based products may damage the gaskets APPLICATIONS Area lighting for ships Suitable for harsh environments APPROVALS SAFETY PRECAUTIONS Note that changes to the product and or installation of components which do not conform to the approval may be a safety violation The manufacturer will not under...

Page 3: ...pment during transporta tion is not the responsibility of R Stahl Tranberg AS If the content is not complete file a claim to the manufacturer immediately The TEF 2580 is delivered with a standard mounting brack et The floodlight must be mounted on a flat surface coinci dent with the mounting bracket Any damage caused by the use of an incorrect combination of cable and cable gland is not the respon...

Page 4: ...conductor around the live conductors 1 As a result the PE conductor will be pulled out of the terminal block last if strong tension is exerted on the cable 3 Insert the cable into the terminal nut 4 Fix the wires in the conductor support of the splice body 2 5 Cut off the wires with a diagonal cutter flush on the splice body 3 6 When connecting the terminal nut to the light connec tor socket make ...

Page 5: ...on Part No Cable termination nut Ø6 11 mm 50500223 Cable termination nut Ø9 16 mm 50091435 Plug connector for cable Ø6 11 mm 50500224 Plug connector for cable Ø9 16 mm 50500225 Protective cap for unused cable entries IP68 50500226 Breather plug M12 IP68 50091434 Blind plug M25 50091436 ...

Page 6: ... 5000K 70 CRI Power consumtion Up to approx 300 W Ingress Protection IP66 Weight Approx 20 kg with box 21 55 kg Mounting Several mounting options available Cable entries 2x Phoenix QPD quick installation plugs for cable up to 2 5mm2 Operating temperature 40 C to 55 C Light distribution Narrow Medium Wide and Oval Details available upon request Light source LED Mounting Details 250Axxxxx DIMENSIONS...

Page 7: ...in the conductor support of the splice body Cut off the wires with a diagonal cutter flush on the splice body When connecting the QUICKON nut and QPD component make sure that their markings are aligned Screw the QUICKON nut together with the QPD component For this we recommend using either the socket wrench QSS a wrench or a pliers Screw the QUICKON nut as far as it will go or with the spec ified ...

Page 8: ...g com Main office Strandsvingen 6 N 4032 Stavanger Norway T 47 51 57 89 00 E info no st r stahl com Office Oslo Luhrtoppen 2 N 1470 Lørenskog Norway T 47 24 08 44 10 E info no os r stahl com TEF 2580 LED BLUELINE FLOODLIGHT USER MANUAL ...

Reviews: