ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT —

This Document is 

customer property

 and is to remain with this unit.  Please return to service informa-

tion pack upon completion of work.

 

HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

WARNING:

Installer’s Guide

A. GENERAL INFORMATION

WARNING

!

THIS INFORMATION IS FOR USE BY INDIVIDUALS
HAVING  ADEQUATE BACKGROUNDS OF ELECTRICAL
AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO
REPAIR A CENTRAL AIR CONDITIONING PRODUCT
MAY RESULT IN PERSONAL INJURY AND/OR PROP-
ERTY DAMAGE. THE MANUFACTURER OR SELLER
CANNOT BE RESPONSIBLE FOR THE INTERPRETA-
TION OF THIS INFORMATION, NOR CAN IT ASSUME
ANY LIABILITY IN CONNECTION WITH ITS USE.

CAUTION

!

To prevent shortening its service life, the air handler
should not be used during the finishing phases of con-
struction. The low return air temperatures can lead to
the formation of condensate. Condensate in the pres-
ence of chlorides and fluorides from paint, varnish,
stains, adhesives, cleaning compounds, and cement
creates a corrosive condition which may cause rapid
deterioration of the cabinet and internal components.

These instructions do not cover all variations in sys-
tems or provide for every possible contingency. Should
further information be desired or particular problems
arise which are not covered sufficiently by this manual,
contact your local distributor or the manufacturer as
listed on the air handler nameplate.
These Air Handlers are shipped from the factory in the
upflow or horizontal right configuration and are fully
convertible to downflow or horizontal left. Refer to Sec-
tion C beginning  on page 3  for additional information.

INSPECTION

Check carefully for any shipping damage. This must be
reported to and claims made against the transportation
company immediately. Check to be sure all major com-

Convertible Variable Speed – Air Handlers  3.5 - 5 Ton

CONTENTS

General Information .............................................. 1

Installation Limitations & Recommendations ...................... 1

Two Piece Cabinet Disassembly ........................ 3

Unit Installation ...................................................... 4

Vertical Upflow ....................................................................... 4
Vertical Downflow ................................................................... 4
Horizontal Left ........................................................................ 7
Horizontal Right ..................................................................... 8

Refrigerant Piping ................................................. 8

Condensate Drain Piping ...................................... 9

Electrical - Wiring ................................................. 10

Airflow Adjustment ............................................... 10

Hook Up Diagrams ............................................... 12

Outline Drawings ................................................. 15

Checkout Procedures .......................................... 18

ponents are in the unit. Any missing parts should be re-
ported to your supplier at once, and replaced with au-
thorized parts only.

CAUTION

!

Cardboard packing material must be removed from in-
side the blower assembly before starting the unit.
Failure to do so may cause indoor blower motor failure.

INSTALLATION LIMITATIONS & RECOMMENDATIONS

The general location of the air handler is normally se-
lected by the architect, contractor and/or home owner
for the most effective application and satisfaction.

NOTE: Condensation may occur on the surface of the
air handler when installed in an unconditioned loca-
tion. When units are installed in unconditioned spaces,
verify that all electrical and refrigerant line penetrations
on the air handler are sealed completely.

18-GE12D1-8

NOTE:  Version française sur la page 17.

4TEE3F39A1000A, 4TEE3F48A1000A,
4TEE3F48B1000A, 4TEE3F64A1000A

NOTE: The 4TEE3F48B air handler should NOT be
installed in the horizontal left or down flow
configuration unless the outdoor unit has an AHRI
rating with 18-GJ23D1 in the AHRI Directory.  System
ratings listed without 18-GJ23D1 are for horizontal
right and upflow configurations only.  The
manufacturer recommends installing only approved,
matched indoor and outdoor systems.

Summary of Contents for 4TEE3F39A1000A

Page 1: ...for additional information INSPECTION Check carefully for any shipping damage This must be reported to and claims made against the transportation company immediately Check to be sure all major com Co...

Page 2: ...fuel device be installed and or operated in the same closet alcove or utility room In addition these air handlers are suitable for installa tion in an attic garage or crawl space with ducted sup ply a...

Page 3: ...placed on a plenum TAYPLNM100 Connecting return duct directly to the side front or rear of the cabinet is not ap proved 12 Route refrigerant condensate drain lines away from air handler so they do not...

Page 4: ...es so NOT to puncture the coil tubing c Position unit on Pedestal or other suitable foun dation If Pedestal is not used a frame strong enough to support the total weight must be pro vided Provide a mi...

Page 5: ...twork connections are made seal air tight and per Local codes DOWNFLOW BAFFLE KIT X X 7 8 GASKET SCREWS TO REMOVE COIL SCREWS TO REMOVE COIL DISCARD DRIP TRAY 1 2 GASKET INSIDE SURFACE OF BAFFLE 7 8 G...

Page 6: ...PAN TO CLEAR TABS ON COIL CHANNEL SUPPORTS FOR DOWNFLOW OR HORIZONTAL LEFT APPLICATIONS DRAINPAN SHOWN IN PLACE TAB AS MOUNTED ON COIL CHANNEL SUPPORT Figure 10 TO REMOVE BLOWER ASSEMBLY WHEN COIL IN...

Page 7: ...as well as the middle to prevent sagging The service access must remain unobstructed If the unit is sup ported along the length of the front and back with rails the air handler only needs to be sus p...

Page 8: ...urn opening shown in the outline drawings i Openings where field wiring enters the cabi net must be completely sealed Location of power entry is shown on the outline drawing Use 2 5 clear stickers pro...

Page 9: ...o secondary drain connections are provided for the different orientations See Figure 17 The lower of the two should be connected as a backup to prevent conden sate overflow by a blocked primary drain...

Page 10: ...the drain line to a closed drain sys tem 9 Use Teflon tape on the air handler drain line con nections Do Not Use pipe joint compound or PVC CPVC cement It is always recommended that an auxiliary drain...

Page 11: ...Options Switches 7 8 Auxiliary Heat DIP SWITCHES AS SHIPPED COOLING HEATING AIRFLOW FAN OFF DELAY AUXILIARY HEAT SPEEDS Figure 21 K CHECKOUT PROCEDURE 1 Check the Air Handler installation in accordanc...

Page 12: ...ERS WITH SINGLE STAGE COOLING 2 STAGE HEAT From Dwg No B801074 COMFORT CONTROL VARIABLE SPEED AIR HANDLER HEAT PUMP O D SECTION SINGLE SPEED NOTES 1 LOW VOLTAGE WIRING TO BE NO 18 A W G MINIMUM CONDUC...

Page 13: ...w during the defrost cycle 5 Connect only if used with applicable indoor thermostat 6 When heaters are used discard power leads with polarized plug PM A and connect 1 PF to mating plug in the heater c...

Page 14: ...ER CONTROL BOX AS SHOWN 4TEE3F48 AIR HANDLERS WITH 2 STAGE HEAT PUMP COMFORT CONTROL VARIABLE SPEED AIR HANDLER HEAT PUMP O D SECTION 2 STAGE NOTES 1 LOW VOLTAGE WIRING TO BE NO 18 A W G MINIMUM CONDU...

Page 15: ...18 GE12D1 8 15 Installer s Guide OUTLINE DRAWING FOR 4TEE3F39 48 64 From Dwg D802101 Rev 9...

Page 16: ...12D1 8 Installer s Guide 4TEE3F39 48 64 AIR HANDLERS DIMENSIONAL DATA Model No H W 4TEE3F39A1000A 57 90 23 50 4TEE3F48A1000A 4TEE3F48B1000A 4TEE3F64A1000A 4TEE3F39A 48A 48B 60A Are two piece cabinets...

Page 17: ...18 GE12D1 8 17 Installer s Guide...

Page 18: ...r size per nameplate specifications 4 Check control box panel in place and secured NOTE OPERATION OF HEATERS MUST BE CHECKED DURING THE OPERATION CHECK OF THE TOTAL SYSTEM 1 Make sure power is OFF at...

Reviews: