background image

 

Rear Blower Installation Instructions 

99000138

 

 

 

 

Page 1 of 6 

17601035 - 8/18/10 

© Travis Industries, Inc.  

Compatibility (Freestanding Models Only) 

• Lopi Answer     • Lopi Endeavor      • Lopi Liberty     • Lopi Leyden 

• Avalon Pendleton (745/790)      • Avalon Rainier (945/990)      • Avalon Olympic (1190)   • Avalon Arbor 

• 1250 Wood Stove        • 1750 Wood Stove 

Packing List 

• Rear Blower       • Snap Disk Assembly        • Snap Disk Hanger       • Three 1/4" 20 Thread Cutting Screws 

Operating Instructions 

The blower will not turn on until the appliance is up to temperature.  Once up to temperature, the blower will 
operate at the speed determined by the position of the blower knob (see the illustration below).  The blower 
shuts off once the appliance cools.   

 

Installation Instructions (All Except Leyden, Arbor, and 1750) 

1.  Install the stove legs or pedestal.  Remove the two rear blower knock-outs underneath the base (see the 

illustration below). 

 

2.  For the Endeavor and Liberty follow step 2B.  For all other models, follow step 2A. 

2A   Install the snap disk assembly into the left side convection chamber following the directions below. 

OFF

 

Turn the knob 
all the way 
counter-
clockwise to 
turn off.

HIGH 

Turn the knob 
clockwise from 
the off position 
until it clicks.

LOW 

Turn the knob 
all the way 
clockwise to 
turn to low.

Outside Air Knock-Out 
for standard pedestals

Drop Chute Knock-Out
- found on Olympic 
(1190) and Rainier (990) 
only.

Rear Blower Knock-Outs

Ashpan Pedestal/Air Boot 
Outside Air Knock-Out 

FRONT OF STOVE

REMOVE THESE KNOCK-OUTS

Ashlip

Bend these legs on 
the snap disk if it 
does not fit tightly

Wedge the snap disk 
directly in front of the 
stiffener on the left side.

Twist the wires together and feed them 
through the convection chamber and 
out of the knockout removed in step 1.

Snap Disk 
Assembly

Summary of Contents for 1250 Insert

Page 1: ... or pedestal Remove the two rear blower knock outs underneath the base see the illustration below 2 For the Endeavor and Liberty follow step 2B For all other models follow step 2A 2A Install the snap disk assembly into the left side convection chamber following the directions below OFF Turn the knob all the way counter clockwise to turn off HIGH Turn the knob clockwise from the off position until ...

Page 2: ...operly secured to prevent the wire from contacting the firebox and shorting out the blower circuit Slide the wire clip over the edge of the strip of metal between the two knock outs Feed the two snap disk wires into the eye of the wire clip Then carefully remove all slack from the wire making sure not to dislodge the snap disk Pinch the eye of the wire clip to secure the wires Wire Clip Snap Disk ...

Page 3: ...quick connects All Other Models Feed the wires directly upwards NOTE Prior to attaching the blower tuck all excess wire into the area inside the blower The blower attaches to the stove with the three included screws Use a 3 8 socket driver or wrench HINT Attach the screws to the back of the stove prior to attaching the blower This will cut the threads and ease installation Plug the power cord into...

Page 4: ...ition the blower near the rear of the stove Tuck all excess wire into the blower box making sure it does not contact any moving parts Make sure when installing the blower these wires do not become loose b c Snap Disk Assembly Snap Disk Extender Ashlip Wedge the snap disk into the convection channel so Bend the legs on the extender if necessary so the snap disk contacts the firebox Twist the wires ...

Page 5: ...n the rear heat sheild and the cast iron firebox Bend the legs of the thermodisk bracket to make it 1 1 2 deep 1 1 2 a 3 8 Wrench g Plug the blower in Do not route the power cord under or over the stove or in a location where it may become damaged b c Route the wires from the blower through the hole in the back of the blower housing Attach these wires to the thermodisk wires Position the blower ne...

Page 6: ...35 8 18 10 Travis Industries Inc Leyden and Arbor Installation Instructions Rev 005 or Later The following instructions are for Leyden and Arbor wood stoves with the built in thermodisk serial 1110 009120 or greater for Leyden serial 1307 003086 or greater for Arbor ...