Summary of Contents for 24324-03

Page 1: ...e ASK electronic Access Security Keyless entry CAN Multiplex System CAN Multiplex System Installation Instructions UM27 24324 03...

Page 2: ...pad 1 e FOB Operation and Features 2 Additional Features 2 Dome Porch Light Activation 2 e PAD Anti tamper Deactivating Feature 2 Teaching Keypad New Authority Access Codes 2 Assign New Access Codes 3...

Page 3: ...5 7 8 7 8 7 8 7 8 7 8 Access code Authority code Locking Doors With Keypad Press and hold down the 1 2 button for 1 2 seconds An access code is not needed to lock the doors Unlocking Doors With Keypad...

Page 4: ...eactivating Feature After repeated attempts to enter code 20 button presses without enabling the keypad enters an inactive mode that disables button for 1 minute This helps prevent access by entering...

Page 5: ...2 Enter the 5 digit authority code see page above Keypad will provide a long beep that will stop after you have defined an access number 3 Press and release any button This button corresponds to the a...

Page 6: ...nds The keypad will beep and the LEDs will flash 2 Enter authority code Keypad will provide a sustained beep 3 Press and hold 9 0 for 5 seconds A double beep plays a The receiver module is now in FOB...

Page 7: ...ntil fast LED flash This synchs the 2nd FOB transmitter 9 Repeat step 8 until all FOBs are synched up to 4 FOBs 10 Remove power and CAN from door module 11 Move DIP switches 4 6 to original position a...

Page 8: ...standard FOB or cargo FOB On Cargo FOB Off Standard FOB 2 button DIP Switch 8 The setting of DIP switch 8 defines the type of CAN protocol either RV C or SAE J1939 Fire truck and ambulance application...

Page 9: ...up input Black Right Header Connector Deutsch DT06 12SB currently 128B Terminal Deutsch 1062 16 1122 Wedgelock W128 currently 128 Wiring Assignments 1 Dome Light output 2 Antennae pin 3 CAN Low 4 Doo...

Page 10: ...sponse with button press Verify power to the I O module Verify that keypad cable is connected rest of system will function Access code is not recognized Verify that code has not been changed Reassign...

Page 11: ...are set to correct configuration setting No response in any system element LED flashing LED is under enclosure cover I O module is detecting problem with communication network CAN Check that network...

Page 12: ...UM27 24324 03 09 11 2...