APPLICATION

:

 Remote central station notification

 Local alarm monitoring

 Triggering video surveillance and

    recording systems

 Active relay for trap door systems

 For Indoor applications ONLY.

TECHNICAL SPECIFICATIONS

:

 SHARP

®

 

 Infrared optical sensor

 Normally Open and Normally Closed

    contact terminals

 Single pole, double throw, Form "C"

    relay, rated at 1 Amp at 24 VAC or

    24 VDC.

 Sensor Power - 12 through 30 VDC (ONLY) 

FEATURES

:

 Non-Mechanical operation

 Sensor is concealed within the unit

 Sensor does not require any adjustment

 Ignores ambient light, detecting radiant

    Infrared reflections off the pullman latch

Increase life and decrease in maintenance

    due to electronic versus mechanical

    operation

SENSOR WIRE

COLOR CODE

POWER LEADS:

Red        -   Positive

Black      -  Negative

RELAY LEADS:

Blue        -  Common

Yellow     -   Normally Open (NO)

White      -   Normally Closed (NC) 

INFRARED

SENSOR

WIRING SCHEMATICS FOR TYPICAL APPLICATIONS

PREINSTALLATION CONSIDERATION:

When Mounting the 4800FLB, the pullman latch must be positioned as close 

as possible to the vertical center of the latch cavity. Having the latch on 

center will ensure that the sensor will have enough surface to detect.
You can use the 1/8" and 1/4” spacer (included, 1/4” is for 4850LB only) to

move the 4850LB/4800FLB closer to the panic bar. 

Spacer Plate

                          QUIESCENT                    TRIGGER

VOLTAGE     CURRENT DRAW         CURRENT DRAW
    12VDC                13mA                          23mA

    24VDC                20mA                          35mA

    30VDC                22mA                          39mA

WHITE - NORMALLY CLOSED (

NC

)

RED +
BLACK -

BLUE COMMON (

COM

)

YELLOW - NORMALLY OPEN (

NO

)

NOTE:

Please observe proper polarity for the LB sensor. The RED wire

terminal must be attached to the POSITIVE side and the BLACK wire

terminal must be attached to the NEGATIVE side.

TO TRANSFORMER

12V THROUGH 30V DC

RELAY TERMINALS

TO USER DEVICE OR

SENSORS.

LB SENSOR WIRE TERMINAL

COLOR CODING ASSIGNMENTS

RELAY

COMMON

NC

NO

TRANSFORMER

POWER

BUZZER OR

BELL

RELAY

COMMON

NC

NO

SECURITY SENSOR

For an alarm system a 

Buzzer of Bell can be 

wired to the NO terminal 

such that when the door 

is open the Buzzer or Bell 

will sound.

For a security system 

setup one side of the 

circuit can be connected 

to the common and the 

other side to the NC 

terminal so that when the 

door is open, the system 

senses the relay switch 

as open

INSTRUCTION SHEET

SPECIFICATION AND 

P: (203) 730-1756  --  F: (203) 730-1781 

www.trineonline.com

4850LB/4800FLB