background image

1. Introduction

The Triplett Model 1301 multimeter is a 3 1/2 digit, handheld digital multi-

meter with automatic power off and a backlit LCD display. Using a Large  

Scale Integration (LSI) integrated circuit, the multimeter is designed for  

stability and accuracy. The resilient outer molded cover provides additional  

protection from the occasional fall, and the threaded probe tips and screw  

on insulated clips provide for secure, hands-off measurements. The meter 

can measure AC and DC voltage, AC and DC current, resistance, capaci-

tance, temperature, and forward diode voltage drop.  It can also perform an 

audible continuity test, non-contact AC voltage detection, and test both 1.5V 

and 9V batteries.

2. Product Features

1) Test lead holder.

2) CDS sensor for automatic backlight brightness control.

3) NCV Detection area (top of DMM case).

4) NCV Detection voltage detected indicator (red LED).

5) NCV Detection mode activated indicator (green LED)

6) LCD display with   (Low Battery), NCV, and DH (Hold) annunciators.

7) 

POWER

 Button: Press the Power Button to turn the unit on or off.

8) 

NCV

 Button: Press and hold to activate NCV mode. 

9) 

DISPLAY HOLD

 Button: Press the “

HOLD

” key to lock the present value     

    on the display. The “

DH

” sign will appear on the display while the hold  

    function is active.  Press it again to exit and resume normal display 

    updating.

10) Rotary Switch: Use this switch to select test functions and ranges.

11) 

COM:

 COM and Temperature “-” Input Jack.

12) 

10A:

 10A Input Jack, unfused.

13) 

VΩmA:

 V/mA/BATT/ 

 and Temperature “+” Input Jack, fused at 

      200mA, 500V

14) Meter case

15) Protective molded cover

3. Safety Information

3-1

 The meter is designed according to IEC-1010 concerning electronic  

       measuring instruments with an over-voltage category level of 600V  

       (CAT III) and pollution level 2.  

DO NOT USE THIS METER FOR CAT  

       IV APPLICATIONS.

3-2

 Follow all safety and operating instructions to ensure that the meter is  

      used safely and is kept in good operating condition.

3-3

 Safety symbols:

      

 

Important safety information, refer to the operating manual.

      

 

Dangerous voltage may be present.

      

 

Double insulation (protection Class II)

4. Cautions and Warnings

4-1

 To maintain product safety, use the provided test leads. Damaged test  

      leads should be replaced with the same model or test leads with the  

      same electrical specifications.

4-2

 Do not use with the battery cover removed.

4-3

 Always set the rotary switch to the correct position for measurement.

4-4

 Do not exceed the input limits.

4-5

 Do not change the rotary switch setting when the leads are connected to  

      an energized circuit.

4-6

 Use caution when measuring voltages higher than 60V DC or 30V AC.

4-7

 Replace fuse with fuse of the same rating.

4-8

 To conserve battery life, always turn the meter off when measurements  

      are completed.  

5. General Characteristics 

5-1

 Max Voltage between input terminal and Earth Ground: CAT III 600V

5-2

 Over-range Indication: display “1” or “-1” for the most significant digit

5-3

 Low Battery Indication:    is displayed

5-4

 Maximum LCD Display: 1999 (3 ½ digits)

5-5

 Manual range selection

5-6

 Auto Power Off: The meter will switch to standby mode when it has 

      been on for approximately 20 minutes. Press the “

POWER

” button twice  

      to power on the meter again

5-7

 Fuse protection: Fast acting 200mA/500V

5-8

 Power supply: 9V battery (6F22 or NEDA 1604)

5-9

 Operating Temperature: 0°C to 40°C (relative humidity <85%)

5-10

 Storage Temperature: -10°C to 50°C (relative humidity <85%)

5-11

 Dimension: 150x106x36mm

5-12

 Weight: approx. 250g (including battery)

6. Measurement Specifications

Accuracy is specified from 18°C to 28°C (64°F to 82°F) with relative 

humidity below 70%.

DC Voltage

Range

Resolution

2V

1mV

20V

10mV

200V

100mV

600V

1V

Accuracy

±(0.5% of rdg + 2 digits)

±(0.8% of rdg + 2 digits)

Impedance: 10MΩ

Overload protection: 600V DC or AC

AC Voltage

Range

Resolution

200V

100mV

600V

1V

Accuracy

±(1.2% of rdg + 5 digits)

Impedance: 10MΩ

Overload protection: 600V DC or AC rms

Frequency Range: 40 to 400Hz

Response: Average, calibrated equivalent to RMS of sine wave

DC Current

Range

Resolution

200mA

100μA

10A

10mA

Accuracy

±(1.2% of rdg + 2 digits)
±(2.0% of rdg + 3 digits)

Overload protection: Fast Acting 200mA / 500V fuse

10A input is not fuse protected. Apply no more than 10A for less than 10 seconds

Resistance

Range

Resolution

200Ω

0.1Ω

2kΩ

20kΩ

10Ω

200kΩ

100Ω

2MΩ

1kΩ

20MΩ

10kΩ

Overload protection: 500V AC / DC

Accuracy

±(1.0% of rdg + 2 digits)

±(1.5% of rdg + 3 digits)

±(1.0% of rdg + 3 digits)

M

odel

 1301

Compact Digital 

MultiMeter

Instruction Manual

AC Current

Range

Resolution

200mA

100μA

10A

10mA

Accuracy

±(1.5% of rdg + 3 digits)
±(2.5% of rdg + 5 digits)

Overload protection: Fast Acting 200mA / 500V fuse

10A input is not fuse protected. Apply no more than 10A for less than 10 seconds

Frequency Range: 40 to 400Hz

Response: Average, calibrated equivalent to RMS of sine wave

Reviews: