1. Introduction
The Triplett Model 1301 multimeter is a 3 1/2 digit, handheld digital multi-
meter with automatic power off and a backlit LCD display. Using a Large
Scale Integration (LSI) integrated circuit, the multimeter is designed for
stability and accuracy. The resilient outer molded cover provides additional
protection from the occasional fall, and the threaded probe tips and screw
on insulated clips provide for secure, hands-off measurements. The meter
can measure AC and DC voltage, AC and DC current, resistance, capaci-
tance, temperature, and forward diode voltage drop. It can also perform an
audible continuity test, non-contact AC voltage detection, and test both 1.5V
and 9V batteries.
2. Product Features
1) Test lead holder.
2) CDS sensor for automatic backlight brightness control.
3) NCV Detection area (top of DMM case).
4) NCV Detection voltage detected indicator (red LED).
5) NCV Detection mode activated indicator (green LED)
6) LCD display with (Low Battery), NCV, and DH (Hold) annunciators.
7)
POWER
Button: Press the Power Button to turn the unit on or off.
8)
NCV
Button: Press and hold to activate NCV mode.
9)
DISPLAY HOLD
Button: Press the “
HOLD
” key to lock the present value
on the display. The “
DH
” sign will appear on the display while the hold
function is active. Press it again to exit and resume normal display
updating.
10) Rotary Switch: Use this switch to select test functions and ranges.
11)
COM:
COM and Temperature “-” Input Jack.
12)
10A:
10A Input Jack, unfused.
13)
VΩmA:
V/mA/BATT/
and Temperature “+” Input Jack, fused at
200mA, 500V
14) Meter case
15) Protective molded cover
3. Safety Information
3-1
The meter is designed according to IEC-1010 concerning electronic
measuring instruments with an over-voltage category level of 600V
(CAT III) and pollution level 2.
DO NOT USE THIS METER FOR CAT
IV APPLICATIONS.
3-2
Follow all safety and operating instructions to ensure that the meter is
used safely and is kept in good operating condition.
3-3
Safety symbols:
Important safety information, refer to the operating manual.
Dangerous voltage may be present.
Double insulation (protection Class II)
4. Cautions and Warnings
4-1
To maintain product safety, use the provided test leads. Damaged test
leads should be replaced with the same model or test leads with the
same electrical specifications.
4-2
Do not use with the battery cover removed.
4-3
Always set the rotary switch to the correct position for measurement.
4-4
Do not exceed the input limits.
4-5
Do not change the rotary switch setting when the leads are connected to
an energized circuit.
4-6
Use caution when measuring voltages higher than 60V DC or 30V AC.
4-7
Replace fuse with fuse of the same rating.
4-8
To conserve battery life, always turn the meter off when measurements
are completed.
5. General Characteristics
5-1
Max Voltage between input terminal and Earth Ground: CAT III 600V
5-2
Over-range Indication: display “1” or “-1” for the most significant digit
5-3
Low Battery Indication: is displayed
5-4
Maximum LCD Display: 1999 (3 ½ digits)
5-5
Manual range selection
5-6
Auto Power Off: The meter will switch to standby mode when it has
been on for approximately 20 minutes. Press the “
POWER
” button twice
to power on the meter again
5-7
Fuse protection: Fast acting 200mA/500V
5-8
Power supply: 9V battery (6F22 or NEDA 1604)
5-9
Operating Temperature: 0°C to 40°C (relative humidity <85%)
5-10
Storage Temperature: -10°C to 50°C (relative humidity <85%)
5-11
Dimension: 150x106x36mm
5-12
Weight: approx. 250g (including battery)
6. Measurement Specifications
Accuracy is specified from 18°C to 28°C (64°F to 82°F) with relative
humidity below 70%.
DC Voltage
Range
Resolution
2V
1mV
20V
10mV
200V
100mV
600V
1V
Accuracy
±(0.5% of rdg + 2 digits)
±(0.8% of rdg + 2 digits)
Impedance: 10MΩ
Overload protection: 600V DC or AC
AC Voltage
Range
Resolution
200V
100mV
600V
1V
Accuracy
±(1.2% of rdg + 5 digits)
Impedance: 10MΩ
Overload protection: 600V DC or AC rms
Frequency Range: 40 to 400Hz
Response: Average, calibrated equivalent to RMS of sine wave
DC Current
Range
Resolution
200mA
100μA
10A
10mA
Accuracy
±(1.2% of rdg + 2 digits)
±(2.0% of rdg + 3 digits)
Overload protection: Fast Acting 200mA / 500V fuse
10A input is not fuse protected. Apply no more than 10A for less than 10 seconds
Resistance
Range
Resolution
200Ω
0.1Ω
2kΩ
1Ω
20kΩ
10Ω
200kΩ
100Ω
2MΩ
1kΩ
20MΩ
10kΩ
Overload protection: 500V AC / DC
Accuracy
±(1.0% of rdg + 2 digits)
±(1.5% of rdg + 3 digits)
±(1.0% of rdg + 3 digits)
M
odel
1301
Compact Digital
MultiMeter
Instruction Manual
AC Current
Range
Resolution
200mA
100μA
10A
10mA
Accuracy
±(1.5% of rdg + 3 digits)
±(2.5% of rdg + 5 digits)
Overload protection: Fast Acting 200mA / 500V fuse
10A input is not fuse protected. Apply no more than 10A for less than 10 seconds
Frequency Range: 40 to 400Hz
Response: Average, calibrated equivalent to RMS of sine wave