Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
saleshelp@tripplite.com
Model Number: PDU3VSR6H50A
3-Phase Switched PDU, 14.4 kW, 18 208V outlets (6-C13, 12-C19) 6-ft. Cord, Hubbell CS8365C 50A input, 0U
vertical mount
Highlights
Switched 14.4kW 3 Phase 208V PDU; 70 in. / 178cm 0U vertical rackmount
Reports voltage, frequency & load per-outlet or phase via ethernet interface
Digital display reports detailed status information; Toolless button-mount
installation
Hubbell CS8365C 50A 208V 3 phase input (3P+E); 6 ft. / 1.8m line cord
6 C13 & 12 C19 single phase switched outlets with Plug-lock cable retention
inserts
Temperature, humidity and contact closure monitoring options
Description
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle
or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or
per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP,
Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom
programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent
inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of
unauthorized hardware. Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values
per outlet, per breaker bank and per phase with additional reporting options for power unbalance percentage, IP address and sensor based
temperature and humidity data (requires ENVIROSENSE sensor).
Applications
Ideal for 3 phase network configurations in datacenters and heavily configured equipment racks
Package Includes
Switched rackmount PDU with pre-installed mounting buttons
6 C13/C14 and 12 C19/C20 Plug-lock inserts
Spare installation buttons (2 9mm / 4 6mm)
Rack mounting brackets
Owner's manual
Features
14.4kW 3 phase 208V Switched Power Distribution Unit / PDU with built-in web/network interface
Attached Hubbell CS8365C 50A (3P+E) 208V 3 phase input; 6 ft. / 1.8m cord
0U, 70 inch / 178cm vertical form factor
18 switched 208V outlets (6 C13, 12 C19) in 6 separately breakered 20A single phase load banks
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load levels
Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per
breaker bank and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature
and humidity data (requires ENVIROSENSE sensor)
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4