SmartOnline 10kVA On-Line Double-Conversion UPS, 10U Rack/Tower, 208/120V NEMA outlets

 

Highlights

10kVA / 10,000VA / 9000W on-line double-conversion UPS; 0.9 power factor

208/120V 60Hz output; High efficiency economy mode option

10U Rack/Tower compatible; Hot-swappable power and battery modules

USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card

options

Front panel LEDs with detailed LCD monitoring and control screen

Expandable runtime with optional external battery packs

Hardwire input (3 wire); L6-30R, L6-20R & 5-15/20R outlets

Description

Tripp Lite SU10000RT3U2TF 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical

network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking

applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included

detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected

equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking

applications in data centers, computer rooms, network closets and rugged industrial locations.

Package Includes

SU10000RT3UPM 3U UPS power module

BP240V10RT3U external battery pack

Two SU5000XFMRT2U step down transformers

SUPDMB710 Detachable PDU with manual bypass switch

Four post compatible rack rail kit (4 sets)

Tower stands for upright tower configuration

PowerAlert software, complete data cabling and user manual

Features

Tripp Lite SU10000RT3U2TF 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 10U total rack/tower configuration

(3U UPS power module, 3U external battery pack and two 2U step-down transformers)

Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to

connected networking equipment

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Hardwire input; 2 L6-30R, 4 L6-20R and 24 5-15/20R outlets

Maximum installed rack depth of only 32.5 in. / 82.6cm

Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions

and line noise

Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with

enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS

types

Summary of Contents for SmartOnline SU10000RT3U2TF

Page 1: ...wap replacement options make this UPS ideal for advanced networking applications in data centers computer rooms network closets and rugged industrial locations Package Includes SU10000RT3UPM 3U UPS po...

Page 2: ...IOCARD supports six configurable hard contact closure outputs for custom event notification Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom even...

Page 3: ...S input connection description 3 wire single phase input L1 L2 G Recommended Electrical Service 60A Phase Single Phase BATTERY Full load runtime minutes 4 3 min 9000w Half load runtime minutes 12 5 mi...

Page 4: ...e scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantaneous EMI RFI AC noise sup...

Page 5: ...luded battery pack dimensions height x width x depth inches 5 25 x 17 5 x 25 Included battery pack dimensions height x width x depth cm 13 3 x 44 4 x 63 5 Included battery pack weight lbs 158 7 Includ...

Page 6: ...double conversion mode Transfer time economy mode 8 ms typical power failure response in optional economy mode Low voltage transfer to battery power setpoint 100V High voltage transfer to battery pow...

Page 7: ...ackmount NEMA 5 15 20R outlets NEMA L5 20P input with 5 20P adapter 1 PDUMNV20HV Monitored PDU Power Distribution Unit supports real time remote monitoring of load level voltage and frequency with opt...

Page 8: ...Power Adapter cord NEMA L5 20R to NEMA 5 20P 1 More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products...