Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
saleshelp@tripplite.com
Model #: SU1500RTXL2UA
SmartOnline 1.5kVA On-Line Double-Conversion UPS, 2U Rack/Tower, 100/110/120V NEMA outlets
Highlights
1500VA / 1.5kVA / 1200 watt on-line double-conversion 2U rack/tower UPS
100/110/120V +/-2% output at 50/60Hz, high efficiency economy mode option
Expandable runtime, Hot-swap batteries; 19 in / 48.3cm installed depth
USB, RS232 & EPO ports; support for SNMP/WEB card options
Front panel status LEDs with detailed load and battery metering
2 independently switchable output load banks
NEMA 5-15P input; 5-15R outlets
Description
1500VA online, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an
installed depth of only 19 inches. Expandable battery runtime with optional BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible)
external battery packs. Full-time sine wave 100, 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power
Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates
continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode
saves BTU heat output and energy costs. NEMA 5-15P input plug and NEMA 5-15R output receptacles. Network-grade AC surge and noise
suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB
port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure
monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and
Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network
interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU
switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs.
LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet
connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories
included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rack & wallmount accessories available. Field-replaceable, hot-swappable internal
batteries and external battery packs. Attractive all-black color scheme. $250,000
connected equipment insurance
;
Package Includes
SU1500RTXL2Ua Online Double-Conversion UPS System
PowerAlert Software and cabling
Mounting hardware for 4 post rack enclosures
Instruction manual
Features
SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all
usage conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time