Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
saleshelp@tripplite.com
Model #: SU3000XL
SmartOnline 3kVA On-Line Double-Conversion UPS, Tower, 120V NEMA outlets
Highlights
3000VA / 3kVA / 2400 watt on-line double-conversion tower UPS
110/120V +/-2% output at 50/60Hz, high efficiency economy mode option
Expandable runtime, Hot-swappable batteries
USB, RS232 & EPO ports; support for SNMP/WEB card options
Front panel status LEDs with detailed load and battery metering
2 independently switchable output load banks
NEMA L5-30P input; L5-30R, 5-15/20R & 5-15R outlets
Description
3000VA / 3kVA / 2400 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Attractive
upright tower format. Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US
(multi-pack compatible) external battery packs. Full time sine wave 110/120V output with +/-2% voltage regulation. Uninterruptible Power Supply
(UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates
continuously without using battery power during brownouts to 65V and overvoltages to 150V. Up to 97% efficiency in optional economy mode saves
BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA 5-15/20R and NEMA 5-15R output receptacles. Network-grade
AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include USB port, DB9
serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring
ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. Includes
PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports
automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs.
Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. Field replaceable, hot swappable internal
batteries and external battery packs. $250,000
connected equipment insurance
;
Package Includes
SU3000XL Online, Double-Conversion UPS System
PowerAlert Software and cabling
Instruction manual with warranty information
Features
SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output
during peak operating hours and high efficiency, low BTU emission operation during off-peak times
Maintains continuous operation through blackouts, voltage fluctuations and surges
On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) with zero transfer
time
Supports operation at 50/60Hz (auto-sensing)
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
Corrects line voltage conditions as low as 65V and as high as 150V to within 2% of selected nominal voltage
Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)
Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack
compatible) external battery packs
Some external battery configurations require the use of Tripp Lite's
External Battery Configuration Software
(see manual)