Description

Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS

replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection

available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It

converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating

connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a

6kVA/5400W capacity and hardwire output.

With its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any

skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is

needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery

modules, allowing them to be removed while keeping your application in operation. 

UPS battery backup keeps connected equipment operational through short power failures, and provides time to

save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHW’s

runtime can be expanded with optional external battery packs.

The SU6000RT4UHVHW features a highly efficient (96%) economy mode setting that can significantly reduce a

facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.

An LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD/LED

panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that

signals various conditions.

The SU6000RT4UHVHW features a USB port and a DB9 port that, when used with Tripp Lite's included

PowerAlert software, provide comprehensive network power monitoring and control. An optional

Highlights

Completely user

hot-swappable—no service call

or technician needed 

Protects rackmount servers,

telecom systems and other

networking equipment in

high-voltage environments with

true on-line operation, pure sine

wave output and zero transfer

time to battery

Hardwire input and output with

200/208/220/230/240V 50/60Hz

compatibility

6kVA/5400W capacity in 4U form

factor with power module and

independent, detachable PDU

Hot-swappable power and

battery modules

8.5-minute half-load runtime,

2-minute full-load; expandable

runtime with external battery

packs

Front panel LEDs with detailed

LCD monitoring and control

screen 

USB and RS232 communication

ports with included PowerAlert

software for complete network

power management and control

$250,000 Ultimate Lifetime

Insurance; 2-year warranty

Package Includes

SU6000RT4UHVPM

Hot-swappable UPS Power

Module

SUPDMB6KHW Detachable

PDU with Maintenance Bypass

Switch

PowerAlert Software CD

1 x 6-ft. USB Cable

1 x 6-ft. DB9 Cable

4-Post Rackmount Hardware

1 / 7 

 

Summary of Contents for SmartOnline SU6000RT4UHVHW

Page 1: ...6 economy mode setting that can significantly reduce a facility s energy costs by minimizing heat output reducing cooling requirements and consuming less electricity An LCD display with LED indicators enables IT personnel to operating modes and conditions The LCD LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various cond...

Page 2: ...trical impulses and other hard to solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network grade AC surge and noise suppression Supports detailed monitoring of equipment load levels self test data and utility power conditions via built in RS 232 USB and optional SNMP card slot interfaces UP...

Page 3: ... 10 Output voltage regulation Battery mode 2 Built in UPS output receptacles Hardwire Output receptacle details Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot swappable power module replacement Output AC waveform AC mode Pure Sine wave Output AC waveform battery mode Pure Sine wave INPUT Rated input current at maximum load 31 9A 200...

Page 4: ...itional information and control options Alarms Unique audible alarms for all major UPS environmental and power conditions see manual Alarm cancel operation Alarm cancel switch Switches Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance w...

Page 5: ...0 ft Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Network monitoring port description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards RELAYIOMINI installation requires removal of panel containing USB ports P...

Page 6: ...S System 1 2POSTRMKITHD Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery Pack Components 1 2 9USTAND Enables Tower Placement of Rackmount UPS Systems 1 SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 RELAYIOCARD Programmable Relay I O ...

Page 7: ...Specifications are subject to change without notice Photos may differ slightly from final products 7 7 ...