Description

7,500 VA (7.5kVA) on-line, double-conversion UPS system for critical server, network and telecommunications

equipment. Installs in only 8 rack spaces (3U power module, 3U battery pack and 2U step-down transformer).

Maximum installed rack depth of 32.5 in. Expandable battery runtime with optional BP240V10RT3U and

BP240V32 external battery packs. Full-time sine wave 208 and 120V +/-2% output. Actively converts raw

incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates

continuously without using battery power during brownouts to 156V and overvoltages to 276V. Standard 3-wire

208V hardwire input connection; NEMA L6-30R, L6-20R and Nema 5-15/20R output receptacles. Detachable

input-output PDU module with manual bypass switch enables hot-swap UPS replacement without disrupting

power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC

and battery operation. Network management interfaces support communications via RS-232, contact-closure

port and optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data

and utility power conditions via network interfaces. Includes PowerAlert monitoring software and complete

cabling. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface.

Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC

conversion, DC-to-AC conversion, bypass mode and output power status. LCD panel with scroll buttons offers

detailed diagnostic test information on startup and during self tests, plus real-time data on input and output

voltage, frequency (Hz), load percentage and battery charge level. LED/LCD display panel easily rotates for

viewing in rackmount or tower configurations. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post

rackmount accessories and 2-9USTAND tower kit included; 2POSTRMKITWM two post rackmount hardware

accessories available. Field replaceable, hot-swappable power module and external battery packs. Attractive

all-black color scheme. 2-year warranty and $250,000 

connected equipment insurance

; extended warranty and

service contracts available.

Features

7,500 VA (7.5kVA) on-line, double-conversion UPS system (High voltage input/High AND low voltage output)

Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without

powering off connected equipment

Installs in only 8 rack spaces (3U power module/3U battery pack/2U step-down transformer) with a maximum

installed depth of 32.5 inches 

Offers 9 min. runtime at full load (7500VA/6000W) and 20 min. at half load (3750VA/3000W). Runtime is

expandable with any number of optional BP240V10RT3U external battery packs

Full-time sine wave 208V and simultaneous 120V +/-2% output

Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered

AC output 

Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V

Standard 3-wire 208V hardwire input connection 

2 x NEMA L6-30R, 2 x L6-20R and 12 x 5-15/20R output receptacles 

Highlights

7500VA on-line 8U rack/tower

UPS with expandable runtime

(3U Power 3U Battery

Pack + 2U step-down

transformer)

Detachable PDU with manual

bypass switch enables hot-swap

UPS replacement without

powering off connected loads

Maintains 208V and

simultaneous 120V output

2% output voltage regulation over

an input voltage range of 156 to

276

Enhanced serial communications

ports, SNMP/Web Card Slot and

EPO interfaces

$250,000 Ultimate LIfetime

Insurance (USA & Canada only).

Applications

Ideal for protection of sensitive

electronics in any application

calling for upright tower or 19

inch rackmount UPS protection.

Common applications include

any mix of servers, workstations,

hubs, routers, concentrators, IP

telephony and traditional PBX

switching systems 

Package Includes

3U power module with detachable

hot-swap PDU input/output panel

and bypass switch

3U external battery pack, 2U

step-down transformer

Three sets of 4 post rackmount

rails (one for each of the 2U and

3U components)

One set of tower stands for

upright tower configuration

PowerAlert software, complete

data cabling, user manual with

1 / 4 

 

Summary of Contents for SU7500RT3U1TF

Page 1: ...rackmount hardware accessories available Field replaceable hot swappable power module and external battery packs Attractive all black color scheme 2 year warranty and 250 000 connected equipment insurance extended warranty and service contracts available Features 7 500 VA 7 5kVA on line double conversion UPS system High voltage input High AND low voltage output Detachable input output PDU module w...

Page 2: ...TWM two post rackmount hardware accessories available Field replaceable hot swappable power module and external battery packs Attractive all black color scheme 2 year warranty 250 000 connected equipment insurance Extended warranty and service contracts available Specifications OUTPUT Frequency compatibility 50 60 Hz Output VA 7500 Output watts 6000 Output nominal voltage 208V 120V AC Output volta...

Page 3: ...s main power off on switch plus 2 switches to set and execute scrollable LCD functions Front panel LEDs 6 LED DISPLAY line power bypass inverter charger output AC and battery operation LED LCD display panel easily rotates for viewing in rackmount or tower configurations SURGE NOISE SUPPRESSION EMI RFI AC noise suppression Yes AC suppression response time Instantaneous PHYSICAL Shipping Dimensions ...

Page 4: ...wer Maintains continuous operation during undervoltages as low as 156VAC Below this point output is maintained utilizing battery reserves High voltage transfer to battery power Maintains continuous operation during overvoltages to 276V AC Above this point output is maintained utilizing battery reserves SPECIAL FEATURES Appearance Attractive all black color scheme Cold Start Yes inverter can be col...