Model Number: SUDC208V42P

20-60kVA 3 Phase Power Distribution Center

 

Highlights

Full size Rack Power Distribution Cabinet supports 20-60kVA 3 phase UPS

power distribution in datacenter equipment racks

42 pole breaker panel supports 3 phase 208V and single phase 208V and

120V output to connected equipment

Pre-installed 225A 3 pole main breaker, ground and neutral bars

Secure front and rear doors, removable side panels

Full line of accessories includes circuit breakers, corded receptacle whips and

PDUs

 

Description

Tripp Lite’s SUDC208V42P Power Distribution Cabinet supports 20-60kVA 3 phase UPS power distribution in critical datacenter equipment racks.

Full size rack enclosure with pre-installed 42 pole circuit breaker panel supports 3 phase 208V and single phase 208V and 120V output via optional

corded receptacle whips. Breaker panel includes 225A 3 pole main breaker, ground and neutral bars, plus 1/2 and 3/4 inch knockouts. Rack

enclosure offers secure front and rear doors, removable side panels and shares common dimensions and overhead wiring tray accessories as Tripp

Lite SR42UB rack enclosures. Compatible with Tripp Lite SUBB-series breakers, SUWL-series corded receptacle whips and a full line of compatible

basic, metered, monitored and switched PDUs to support a variety of advanced network configurations.

Features

SUDC208V42P Power Distribution Cabinet supports 20-60kVA 3 Phase UPS power distribution in critical datacenter equipment racks

Full size rack enclosure with pre-installed 42 pole circuit panel supports 3PH 208V and 1PH 208V and 120V via optional corded receptacle

whips

Line up and match power distribution cabinet blends with existing standard datacenter racks for an aesthetically pleasing appearance while

providing convenient connectivity between the centralized 3 phase UPS and protected electronic devices in equipment racks

Breaker panel includes 225A 3 pole main breaker, ground and neutral bars, 1/2 and 3/4 inch knockouts (see Help & Downloads for manual

with detailed wiring information)

Rack enclosure offers secure front and rear doors, removable side panels and shares common dimensions and overhead wiring tray and

ladder accessories as Tripp Lite SR42UB equipment racks

Requires appropriate SUBB-series output circuit breakers (see Related Items for list of compatible SUBB breakers)

Optional SUWL-series cable whips and SUWEL-series extensions support a variety of connector types, voltages and cable lengths (see

Related Items for list of compatible SUWL-series and SUWEL-series cabling accessories)

Specifications

OVERVIEW

Model Type

Cabinets

PHYSICAL