background image

TRT-BA-BF06WP-TC211004TTRT02-002-EN

BF06WP

EN

OPERATING MANUAL

LUXMETER

Summary of Contents for BF06WP

Page 1: ...TRT BA BF06WP TC211004TTRT02 002 EN BF06WP EN OPERATING MANUAL LUXMETER ...

Page 2: ...he immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Do not use the device in potentially explosive rooms or areas and do not install it there Do not use the device in aggressive atmos...

Page 3: ...er devices are malfunctioning during the use of your device Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must have read and understood the operating manual especially the Safety chapter Safety signs and labels on the device Note Do not remove any safety signs stickers or labels from the device Keep all safety ...

Page 4: ...lts can be displayed and saved on the terminal device either numerically or in form of a chart Then the measurement data can be sent in PDF or Excel format The app also includes a report generation function an organiser function one for customer management and further analysis options Moreover it is possible to share measurements and project data with colleagues in another subsidiary If MultiMeasu...

Page 5: ...he batteries from the device Operation Inserting the batteries Note Make sure that the surface of the device is dry and the device is switched off 1 Unlock the battery compartment by turning the lock 5 in a way that the arrow points towards the opened padlock icon 2 Remove the cover from the battery compartment 4 3 Insert the batteries 3 batteries of type AAA into the battery compartment with corr...

Page 6: ...Sensors button Opens the sensors overview 7 Refresh button Refreshes the list of sensors near the terminal device 8 Connect button Connects the displayed sensor to the terminal device Continuous measurement Info Note that moving from a cold area to a warm area can lead to condensation forming on the device s circuit board This physical and unavoidable effect can falsify the measurement In this cas...

Page 7: ...s 2 Press the X T measurement button 13 to switch from continuous measurement to individual value measurement ð Individual value measurement has been selected as measuring mode ð Return to the screen displaying the measured values ð The first measured value is automatically determined and displayed SENSORS MEASUREMENTS REPORTS CUSTOMERS SETTINGS 18 19 17 Refresh measured value BF06WP Brightness 3 ...

Page 8: ...the current recording of measured values Opens the submenu for saving recordings Stopping a recording Proceed as follows to stop recording the measured values 1 Press the REC button 20 ð The context menu for sensors opens 2 Press the Stop recording button 21 ð The context menu for saving the recording opens 3 You can optionally save discard or resume the measurement Saving a recording Proceed as f...

Page 9: ...ta Evaluations Evaluation parameters Values Generate table Generate graphic 29 30 31 32 33 34 Sensors Measurements Reports Customers Settings No Designation Meaning 29 Basic data button Opens an overview of the data saved for the measurement 30 Evaluations button Opens an overview of the evaluations generated for the measurement graphics and tables 31 Evaluation parameters button Opens a menu to s...

Page 10: ...orts Customers Settings No Designation Meaning 37 Display reports button Opens the selected report Creating a new customer Proceed as follows to create a new customer 1 Press the Customers button 38 ð The customers overview opens 2 Press the New customer button 39 to create a new customer ð An input mask for entering all the relevant information opens 3 Enter the information via the input mask and...

Page 11: ...Disconnecting an appSensor Proceed as follows to disconnect an appSensor from the terminal device 1 Press the SENSORS button 6 ð A list of connected and available sensors will be displayed 2 Select the line with the appSensor to be disconnected and swipe left at the red marking 3 Confirm your input ð The appSensor is now disconnected from the terminal device and can be switched off 4 Alternatively...

Page 12: ... that no moisture enters the housing Do not use any sprays solvents alcohol based cleaning agents or abrasive cleaners but only clean water to moisten the cloth Repair Do not modify the device or install any spare parts For repairs or device testing contact the manufacturer Disposal Always dispose of packing materials in an environmentally friendly manner and in accordance with the applicable loca...

Page 13: ...Applied harmonised standards EN 300 328 V2 1 1 2016 11 EN 61326 1 2013 Applied national standards and technical specifications Regulation EC 1907 2006 EN 301 489 1 Draft Version 2 2 0 2017 03 EN 301 489 17 Draft Version 3 2 0 2017 03 EN 61010 1 2010 EN 62479 2010 IEC 62321 3 1 2013 IEC 62321 6 2015 IEC 62321 7 1 2015 IEC 62321 7 2 2017 IEC 62321 8 2017 Manufacturer and name of the authorised repre...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: