background image

Explosion-proof fire
damper

Type FKRS-EU

Supplementary Operating Manual

Read the instructions prior to performing any task!

according to Declaration of Performance
DoP / FKRS-EU / DE / 004

GB/en

Summary of Contents for FKRS-EU Series

Page 1: ...Explosion proof fire damper Type FKRS EU Supplementary Operating Manual Read the instructions prior to performing any task according to Declaration of Performance DoP FKRS EU DE 004 GB en...

Page 2: ...original 2021 TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Germany Germany Phone 49 0 2845 2020 Fax 49 0 2845 202 265 E mail trox de troxgroup de Internet http www troxtechnik com 12 2021 Exp...

Page 3: ...data 6 3 1 FKRS EU with explosion proof spring return actuator 6 3 2 ATEX areas of application 7 4 Electrical connection 8 5 Functional test 10 5 1 FKRS EU with ExMax or RedMax spring return actuator...

Page 4: ...nt statutory regulations This supplementary operating manual is intended for specialist consultants developers and owners of the ventilation systems in which the fire dampers are to be installed This...

Page 5: ...components according to the local electronic waste regulations Correct use The fire damper is used as a shut off device to prevent fire and smoke from spreading through ducting in areas with potentia...

Page 6: ...ght kg Nominal size DN 100 125 150 160 180 200 224 250 280 315 D 99 124 149 159 179 199 223 249 279 314 Weight with spring return actuator 4 8 5 1 5 3 5 5 5 8 6 0 6 2 6 8 7 3 7 9 Spring return actuato...

Page 7: ...ExMax 15 BF TR II 2G Ex h IIC T6 Gb II 2D Ex h IIIC T80 C Db 40 C Ta 40 C 10 m s ExPro TT ExMax 15 BF TR II 2G Ex h IIC T5 Gb II 2D Ex h IIIC T95 C Db 40 C Ta 50 C 10 m s ExPro TT RedMax 15 BF TR II...

Page 8: ...on Functional testing requires a switch that interrupts the voltage supply by others The electrical connection is made in the terminal box The factory installed wiring must not be changed Attention If...

Page 9: ...Wiring example for TROXNETCOM Fig 3 Wiring example for TROXNETCOM 1 Controller 2 AS EM C module 3 FKRS EU 4 Safe area Electrical connection Explosion proof fire damper Type FKRS EU 9...

Page 10: ...2 Damper blade is open Closing opening the fire damper with spring return actuator Fig 5 Thermoelectric release mechanism ExPro TT 1 Push button for functional test Fig 6 Functional test FKRS EU with...

Page 11: ...de will not close To re establish its function connect the power supply Requirement The damper blade is CLOSED 1 Remove the terminal box 1 2 Insert the crank handle 2 into the opening for the spring w...

Page 12: ...Explosion proof fire damper Type FKRS EU 12...

Reviews: