background image

 

Combi 2 E / 4 E CP plus (Australia)

 

 Operating instructions  

Page 2 

Installation instructions 

 

Page 9 

To be kept in the vehicle! 

Summary of Contents for Combi 2E CP plus

Page 1: ...Combi 2 E 4 E CP plus Australia Operating instructions Page 2 Installation instructions Page 9 To be kept in the vehicle...

Page 2: ...ion 5 Gas connection with pressure test point not shown 6 Hot air outlets 7 Recirculated air intake 8 Waste gas discharge 9 Combustion air infeed 10 Electronic control unit 11 Water container 10 litre...

Page 3: ...unit gas mode only LPG for autonomous use electrical mode only 240 V for stationary use on camp sites or gas and electrical mode mixed mode Only possible in heating and hot water mode Heating and hot...

Page 4: ...essure control systems DuoControl CS for dual cylinder gas systems At temperatures of around 0 C or less the gas pressure regulator and the changeover valve should be operated using the EisEx regulato...

Page 5: ...er that has frozen The boiler can be thawed out again by briefly starting it up max 2 minutes Frozen lines can be thawed out by heating up the interior If connected to a central water supply rural or...

Page 6: ...switch If the 12 V power supply is interrupted during operation or during the after run period for example the temperatures within the unit could activate the overheating protection Fig 6 To reset th...

Page 7: ...Dimensions Fig 7 The right to effect technical modifications is reserved Truma warranty policy Truma CP plus The warranty is given by Dometic Pty Ltd Building 3B Digital control panel Truma CP plus pa...

Page 8: ...s Apart from any warranties implied by the Trade Practices Act 1974 or any relevant State legislation all other warranties express or implied whether arising by virtue of statute or otherwise are here...

Page 9: ...on with the original Fig 9 In order to heat the vehicle evenly throughout the heater must be installed in a location in the vehicle that is as central as possible in a wardrobe stowage compartment or...

Page 10: ...e heating device assembly instructions are enclosed with the delivery Installing the wall cowl Permissible duct lengths The length specific ations refer to the combusti on air intake duct Ducts with a...

Page 11: ...et of the unit in confined spaces we recommend the use of the BGC 90 elbow part no 34091 01 This elbow makes it possible to connect a R warm air duct with a diameter of 65 mm or a VR warm air duct wit...

Page 12: ...s 27 28 and safety drain valve 24 have a 12 mm rigid piping connection e g John Guest System For connecting to rigid pipes with other diameters appropiate adapters not included in scope of delivery mu...

Page 13: ...e regulation we recommend that the room temperature sensor be fitted above the entrance door Fig 26 Please ensure that the room temperature sensor is always attached to a vertical wall There may be no...

Page 14: ...from Truma for the different applications Please ask your dealer Other chargers may be used only with a 12 V battery as a buffer Room temperature sensor Attach plug of connecting cable to connection 4...

Page 15: ...Dometic Service C entre if problems are encountered in other countries the relevant service partners should be contacted www truma com Having the e quipment model and the serial number ready see type...

Page 16: ...Road Clayton Victoria 3168 Australia Service Australia Telephone 61 0 3 92 39 10 50 Facsimile 61 0 3 92 39 10 99 Dometic New Zealand Ltd Post Box 12011 1642 Penrose Auckland New Zealand Service New Z...