background image

  Operating instructions 

Page 3

Installation instruct ions 

Page 9 

To be kept in the vehicle!

Ultrastore Rapid GE

Summary of Contents for Ultrastore Rapid GE

Page 1: ...Operating instructions Page 3 Installation instructions Page 9 To be kept in the vehicle Ultrastore Rapid GE ...

Page 2: ...el etc Do not switch the Ultrastore off when showering As long as the Ultrastore remains in operation other people can shower as the water is continually reheated 0 10 20 30 40 50 60 70 80 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 2 minutes 1 minute 1 minute 3 minutes 2 minutes 1 minute Time t minutes 3 minutes 1 minute 2 minutes 1 minut...

Page 3: ... arrant y 8 Installation instructions Intended use 9 Regulations 9 Water heater kit 9 Choice of location 9 Installation of the w ater heater 9 Water connection 10 John Guest System rigid pipe routing 10 Flexible water hose routing 11 Installation of the safety pressure relief drain valve 11 Water pipe routing 11 Gas connection 11 Installation of the control panels 12 Electrical connection 12 V 12 ...

Page 4: ...ames do not smoke switch off all appliances shut off the gas cylinder open the windows and doors do not actuate any electrical switches have the entire system checked by an expert Repairs may only be carried out by an expert During use please observe the regulations of EN 60335 1 2010 according to which this device has not been designed for use by people including children who have restricted phys...

Page 5: ...e Lever in vertical position position f The water heater is now drained directly to the outside via the safety drain valve Check that the water contents have been completely drained 10 litres Sw itching on Gas operation Ultrastore 50 70 b c b a a Red LED Failure b Water heater On 50 C or 70 C c Water heater Off Never operate the water heater without water in it If the cowl is positioned vertically...

Page 6: ...l p c b s as spare parts Disposal The device must be disposed of in line with the administrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Technical data Determined in accordance with EN 15033 or Truma test conditions M anufacturer Truma Gerätetechnik GmbH Co KG P O Box 1252 856...

Page 7: ...appliance wait 5 minutes and switch on again Electrical operation When switching on the heater does not operate No 230 V supply voltage Over temperature sensor has responded Too slow warm up in position 850 W Connect the caravan to the site supply and or check residual current circuit breaker Check water content refill if required close drain valve The electrical heating element is fitted with an ...

Page 8: ... relevant service partners should be contacted see Truma Service Booklet or www truma com Any complaints are to be described in de tail Please also specify the device serial number and date of purchase In order for the manufacturers to be able to determine whether an incident subject to guarantee has occurred the end user must at his own risk bring the device to the manufacturers or send it to the...

Reviews: