TO THE PROFESSIONAL OR INSTALLER:
Instructions must remain with installation.
GENERAL EASY FLUSH SYSTEM
INSTALLATION
Please read these instructions carefully.
Note before you proceed with the
installation of this product that the
manufacturer’s guideline has to be
respected. Failure to comply to instructions
and designed operation of this product,
may void the warranty.
Your product has been carefully packaged
at the factory to prevent damage during
shipping. However, occasional damage
may occur due to rough handling. Carefully
inspect your product for damages that could
cause failures. Report any damage to your
carrier or your point of purchase.
INITIAL START UP PROCEDURES:
1-
Inspect the pump and the sewage tank for
any obvious condition that may necessitates
cleaning, correction, adjustement or repair.
2-
Assure that the pump is secure and vertical
for proper operation.
3-
Assure that there is adequate clearance
from any combustible materials or structure.
Stored materials must be kept away from
the pump.
4-
Assure that the motor is securely plugged
into a proper 'GFCI' electrical outlet.
5-
Test the 'GFCI' outlet by pressing its test
switch. This should prove that the outlet
is energized and will trip off to protect
against a ground fault. Be sure to reset
the 'GFCI' by pressing its reset switch.
(Repeat this step monthly)
6-
Lift the float to assure that the pump will
start when required. (Step 7 below will test
submersible pumps with enclosed floats).
7-
Pour pails of water in the sewage tank to
turn the pump on. Assure that any check
valve present will permit the sewage to flow.
8-
Observe that the plumbing can pump
the sewage safely out of the residence.
(Repeat this step monthly)
SAFETY INTRUCTIONS:
Before installation and operation, follow these
procedures:
A-
Check with your local electrical and
plumbing codes to ensure you comply with
the regulations. These codes have been
designed with your safety in mind. Be sure
you comply with them.
B-
A separate circuit must be lead from the
home electrical distribution panel properly
protected with a fuse or a circuit breaker. We
also required that a ground fault circuit be
used as well as a 'GFCI' receptacle. Consult a
licensed electrician for all wiring.
C-
The ground terminal on the three prong
plugs should never be removed. They are
supplied and designed for your protection.
D-
Never make adjustments to any electrical
appliance or product with the power
connected. Do not only unscrew the fuse
or trip the breaker, remove the power plug
from the receptacle.
IMPORTANT
ELECTRICAL CONNECTION:
For pumping systems using more than one
pump, each pump needs to be connected to a
separate dedicated circuit protected by a fuse
or breaker. This way, the power supply of one
pump will not stop operating if the fuse of one
of the pumps burns or if the breaker of one of
the pumps trips.
IMPORTANT NOTICE:
The following are minimum requirements in
order to protect your residence from flooding.
It is a small investment but it is your personal
responsibility to protect your home, family and
valuables. Failure to comply with the following
requirements will also void your warranty:
-
An Alarm system model T50454 has to be
installed to advise you of any malfunctions.
Pump selection, proper and adequate
installation are a must to comply with local
by-laws and need to be adhered to.