background image

Signal processor

MS96 for flow sensors

MS96-11EX0-R/24VDC

Edition

 • 

2012-10-04T23:35:09+02:00

1 / 2

TURCK Inc. 

ñ

 3000 Campus Drive Minneapolis, MN 55441-2656 

ñ

 Phone: 763-553-7300 

ñ

 Application Support: 1-800-544-7769 

ñ

 Fax 763-553-0708 

ñ

 www.turck.com

Type

MS96-11EX0-R/24VDC

Ident-No.

5231407

Ambient temperature

-20…60 °C

Operating voltage

21…28VDC

No-load current I

0

ð

  125  mA

Output function

Relay output, changover contact

Device designation

É

 II(1) G D [EEx ia] IIC

Protection type

II(1) G D [EEx ia] II C

Ex approval acc. to conformity certificate

TÜV 96 ATEX 1098

Protection class

IP20

Protection class (terminals/housing)

IP20 / IP40

Design

terminal chamber

Dimensions

110x 50x 75 mm

Housing material

Polycarbonate/ABS

Connection

Terminal chamber

Indication: Drop below setpoint

LED red

Indication: Setpoint reached

LED yellow

Indication: Setpoint exceeded

4 x LEDs green

ATEX category II (1) G, Ex Zone 0

ATEX category II (1) D, Ex Zone 20

single-channel signal processor MS96

for connection of an intrinsically safe

flow control sensor in zone 0

adjustment via potentiometer

6 LEDs for display of the flow state

intrinsically safe control circuit, [EExia]

IIC

switch-off delay adjustable in a range of

0…25 s

wire-break monitoring

21…28 VDC

Changeover contact, relay output

Wiring diagram

Functional principle

Signal processors not only supply insertion
and inline sensors with voltage, they also pro-
cess and display the measured signals. De-
vices with MK96…, MS96… and MC96…
housing styles are available. The individual
housing styles are designed for different oper-
ating voltages and feature various output and
supplementary functions. For intrinsically safe
flow sensors it is required to use signal pro-
cessors with intrinsically safe control circuits
of the series MS96…Ex… and MC96…Ex… .

Reviews: