background image

TWIG Beacon is an indoor lone worker alarms solution

Manufacturer:

Twig Com Ltd.

24910 SALO, Finland

www.twigcom.com

Publication number:

 YZ3445-07-EN 

All rights reserved. © Twig Com Ltd.

Due to differences in use, installation and hardware, all settings and 

functions may not be applicable to each device version.

RADIO FREQUENCY (RF) ENERGY

Transmission frequencies and power for TST90EUEx device types in EU are 

listed in the table below.

Transmitter

TX frequency bands 

/ MHz

Max power / dBm

SRD

869.675

5

For any further questions please contact Twig Com support at support@

twigcom.com or +358 40 510 5058.

1. INSTALLATION OF BEACONS

TWIG Beacon Ex has integrated lithium primary battery giving typical 3-4 

year operating time. The operating time can vary according to use and 

environment. 

Mount the beacon to a suitable place based on desired radius for operation. 

There’s a separate instruction leaflet for antenna pattern and directional 

antenna adjusting. Mounting of the beacon should not be done against 

metal wall or behind other metal materials as they are damping the signal 

and can even totally block them in certain directions.

If the beacon must be installed to metal wall, there should be used 25 mm 

thick non-metal spacer between beacon and wall or install the beacon 

sideways. If the beacon has antenna 90-degrees tilted or has separate wire 

antenna it can be mounted directly to metal. However, metal will damp 

signal towards back direction.

Device must be installed vertically like in the picture. Note! The battery 

direction should not be positive pole downwards in any installation because 

it will damage the battery. 

Do not install the Ex beacon to place where static electricity can be created 

e.g. with blowing dust.

Once the beacon is mounted to a desired position it can be turned on 

by inserting the jumper. Once the jumper is connected, the beacon is 

operational. The LED will blink on transmission interval. If the beacon is in 

configuration mode it will blink in 2 seconds interval with two colours.

2. INSTALLING SOFTWARE AND DRIVERS

Connect TWIG Beacon Ex wireless configuration adapter to your computer’s 

USB port. Allow Windows to install drivers automatically. 

Once drivers are loaded, run the program Beacon Configurator. Program 

will show each TWIG Beacon Ex it can currently hear. Note that the location 

of the Beacon configuration box containing similar transceiver as Beacon 

Ex has significant effect. Do not place it on metal tables or close to metal 

shelves.

3. DATA FIELD DESCRIPTIONS

The order of the listed beacon devices can be adjusted by clicking the given 

name in the name field. 

No = Position number to indicate how many beacons are ”visible” to the 

configuration program. 

TWIG Beacon Ex

Quick Guide

Name= ID programmed to the unit. If no name is programmed the field will 

be empty. Maximal length is 8 characters.

Serial number is factory programmed non erasable ID.

Interval is the programmed transmitting interval. Default value is 4 seconds. 

The interval is only shown in programming mode. Changing interval longer 

preserves battery but may result in loss of signal noticed by Protector in 

some cases.

Tx Level = The level of transmission programmed to the Beacon. Default 

value is -20dBm

Rssi = The level of transmission the Configuration unit and also Protector 

can hear the Beacon. 

Packet Count = Number of received data packages

Rec = Data reception is displayed with plus (+) sign. (The minus (-) sign can 

be ignored).

When the beacon is in the configuration mode, the editor (see the picture on 

the left) pops up by clicking the beacon on the list.

When the “Keep on config mode” box is ticked, all beacons in configuration 

mode (marked in bold on the list) remain in the configuration mode 10 

minutes also when outside the configurator coverage area.

When “Keep on config mode” box is not ticked, all beacons in configuration 

mode (marked in bold on the list) will remain in configuration mode for 10 

minutes from start or last configuration. 

If the device is not configured during the given time, the beacon must be 

Reviews: