GT62F-B8026 

 

Service Engineer’s Manual 

 

 

 

 

 
 
 

Summary of Contents for GT62F-B8026

Page 1: ...GT62F B8026 Service Engineer s Manual...

Page 2: ...ity or warranties relating to fitness for a particular purpose or merchantability TYAN retains the right to make changes to produce descriptions and or specifications at any time without notice In no...

Page 3: ...limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freque...

Page 4: ...ncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of...

Page 5: ...list and accessories describes the external components gives a table of key Chapter2 Setting Up This chapter Covers procedures on installing the CPU memory modules add on card and hard drives Give an...

Page 6: ...e of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not...

Page 7: ...ns are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of haza...

Page 8: ...or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rack by yourself a minimum of two people are...

Page 9: ...power to the rack is not overloaded This will reduce the risk of personal injury fire or damage to the equipment The total rack load should not exceed 80 percent of the branch circuit rating Consult...

Page 10: ...y to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare design...

Page 11: ...gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer se...

Page 12: ...e Memory 35 2 1 5 Installing Hard Drives 37 2 1 6 Installing the Add On Card 39 2 2 Rack Mounting 42 2 2 1 Installing the Server in a Rack 43 2 2 2 Installing the inner Rails to the Chassis 43 2 2 3 I...

Page 13: ...e Motherboard 74 Chapter 4 BIOS Setup 76 4 1 About the BIOS 76 4 2 Main Menu 78 4 3 Advanced Menu 80 4 4 Chipset Menu 111 4 5 AMD CBS Menu 116 4 6 Server Management 131 4 7 Security 136 4 8 Boot 141 4...

Page 14: ...system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation GT62F B8026 not only empowers your company in today s demanding...

Page 15: ...2 USB 3 0 port External Drive Bay Type Q ty 2 5 Hot swap NVMe 10 HDD backplane support NVMe SATA 6 0Gb s Supported HDD Interface 2 SATA 6Gb s 8 NVMe 10 2 5 NVMe System Cooling Configuration FAN 4 4cm...

Page 16: ...PHY Realtek RTL8211E Storage SATA Connector 2 SATA DOM Controller Direct from AMD CPU Speed 6 0 Gb s RAID N A M 2 connector 2 M 2 connectors 22110 2280 2260 2242 by PCI E SATA interface NVMe 8 PCI E...

Page 17: ...te platform flash USB 2 0 virtual hub AST2500 IPMI Feature 24 bit high quality video compression 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor Boot from USB devi...

Page 18: ...stem Form Factor 1U Rackmount Chassis Model GT62F Dimension D x W x H 24 6 x 17 2 x 1 72 625 4 x 436 x 43 6mm Motherboard S8026GM2NR LE Gross Weight 20 kg 44 lbs Net weight 10 5kg 23 5 lbs Front Panel...

Page 19: ...MM slots DIMM Type Speed DDR4 ECC RDIMM LRDIMM 2666 2400 Capacity Up to 1 024GB RDIMM LRDIMM Memory channel 8 Channels Memory voltage 1 2V Expansion Slots PCI E 2 PCI E Gen3 x16 slots Pre install TYAN...

Page 20: ...memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management...

Page 21: ...ulation FCC DoC Class A CE DoC Class A VCCI Class A CB LVD Yes RCM Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90...

Page 22: ...1286G62F BP12E 10 B8026 HDD Backplane pre installed 1 M1716G75 Front Panel Board pre installed 1 M1620G62F D PDB or Tiger PDB pre installed 1 M7106 L16 1F Riser Board pre installed 1 M7106 R16 1F Rise...

Page 23: ...s website for service http www tyan com GT62F B8026 Accessory Kit 1 Sliding rail 1 CPU Heatsink 2 US Power Cord 2 EU Power Cord 1 Mounting Ear Kit x1 1 Air Duct 1 MEZZ card screw package 2 2 5 HDD sc...

Page 24: ...e product 1 3 1 System Front View HDD Sequence B8026G62FV10HR NVMe1 NVMe3 NVMe5 NVMe7 NVMe9 NVMe0 NVMe2 NVMe4 NVMe6 NVMe8 HDD Sequence B8026G62FV10HR LE HDD1 SSD1 HDD3 SSD3 HDD5 SSD5 HDD7 SSD7 HDD9 SS...

Page 25: ...reen off Blue Solid On Warning System normal Off System Normal Amber Off System Warning Amber Solid On System alert Amber HDD HDD Ready Off HDD Access Green Blinking HDD Ready Green Off HDD Access Bli...

Page 26: ...GA Port 9 1Gb RJ45 LAN3 from PHY dedicated for BMC IPMI 1 3 3 LED Definitions 1Gbps LAN Port LAN Indication 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Link Activity Right LED Speed No Link...

Page 27: ...AS SATA NVMe hot swap SSDs HDDs 3 M1286G62F BP12E 10 B8026 HDD Backplane 4 4 cabled fans 5 CPU socket Heatsink 6 Memory Slots 7 PCIE3 0 SLOT x24 PESLOT2 8 PCIE3 0 SLOT x24 PESLOT1 9 OCP A Slot OCP1_A...

Page 28: ...revent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap...

Page 29: ...sis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the s...

Page 30: ...Removing the Chassis Cover Follow these instructions to remove GT62F B8026 chassis cover 1 Remove the side screw on the chassis cover as in the small diagram 2 Loosen the Thumb screw on the back side...

Page 31: ...2 1 2 Removing the Air Duct 1 Remove the air duct from the chassis...

Page 32: ...river to loosen the screws securing the force frame in a sequential order 3 2 1 Note The force frame will automatically eject after the captive screws are being released 2 By placing your both index f...

Page 33: ...ion observe the following NOTE During installation observe the following 1 Make sure to push the carrier frame with package towards the end of the rail frame until it clicks into place 2 Do not drop t...

Page 34: ...e with the installed package Then push both edges of the rail frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force fra...

Page 35: ...o the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory...

Page 36: ...DIMM Location...

Page 37: ...eGT62F B8026 supports 10 2 5 Hard Drives Follow these instructions to install a hard drive 2 5 Hard Disk Drive 1 Located at the 2 5 HDD tray 2 Press the locking lever to release the 2 5 SSD HDD tray 3...

Page 38: ...he 4 screws to detach HDD tray bracket 5 Place a hard drive into the drive tray Use four screws to secure the HDD 6 Reinsert the HDD tray into the chassis 7 Press the locking lever to lock the 2 5 SSD...

Page 39: ...ansion slot which is available with riser card The following instructions are for Add On card installation You may refer to the procedures below for the installation 1 Remove the screw of PCI E bracke...

Page 40: ...4 Insert the PCI E card in the direction of arrows as shown...

Page 41: ...5 Screw the PCI E cards firmly to the riser card bracket...

Page 42: ...he necessary components the TYAN GT62F B8026 can be mounted in a rack using the supplied rack mounting kit Rack mounting kit Sliding Rails x 2 Mounting Ears including screws x 2 Screws Kit x 1 Mountin...

Page 43: ...ts have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis into the rack 2 2 2 Instal...

Page 44: ...inner sliding rail forward to secure it to the chassis And secure the inner rail to the chassis with 2 screws 5 Screw the mounting ear to each side of TYAN GT62F as shown using two screws of 6 32 L5 3...

Page 45: ...re the outer rail to the rack using 8 M5 washer A screws for each side 2 2 4 Rack mounting the Server 1 Lift the unit and then insert the inner slide rails into the middle rails 2 Press the white butt...

Page 46: ...http www tyan com 46 3 Secure the mounting ears of chassis to the rack with 2 M5 15L C screws...

Page 47: ...d components including the S8026GM2NRE S8026GM2NR LE Motherboard M1716G75 FPB Front Panel Board M1274G62B BP12 10 B8026 M1286G62F BP12E 10 B8026 Backplane M7106 L16 1F M7106 R16 1F Riser Card System F...

Page 48: ...Follow Chapter 2 1 1 to remove the cover of GT62F B8026 3 4 Replacing the Riser Card 1 The GT62F B8026 has preinstalled 2 riser cards Release the 2 screw to lift the riser bracket from the chassis Rem...

Page 49: ...http www tyan com 49 3 Remove the 2 screws to release the M7106 R16 1F riser card 4 Remove the 2 screws to release the M7106 L16 1F riser card...

Page 50: ...http www tyan com 50 3 4 1 Riser Card Features M7106 L16 1F Riser Card M7106 R16 1F Riser Card...

Page 51: ...r system fans Disconnect the fan cable which you need to replace up 2 Take out the fan module from the chassis 3 Release the rubber screws and the push pins from the fan 4 Replace the failed fan modul...

Page 52: ...ow these instructions to replace the M1274G62B BP12E 10 B8026 M1286G62 BP12E 10 B8026 HDD Backplane 1 First pull the HDD trays slightly forwards to make the HDD BP Board easier to uninstall 5 Disconne...

Page 53: ...http www tyan com 53 7 Remove the eight screws securing the bracket to the HDD backplane...

Page 54: ...SAS SATA HDD Connectors 4 MINI SAS HD Connector connect to MB 2 MINI SAS Connector connect to MB 2 SATA connector connect to MB 1 2 10 Pin FAN connector connect to MB 6 8 Pin FAN connector connect to...

Page 55: ...tor NVMe Connector NVMe Connector NVMe Connector SAS SATA PCIe HDD Connector SAS SATA PCIe HDD Connector SAS SATA PCIe HDD Connector SAS SATA PCIe HDD Connector SAS SATA HDD Connector SAS SATA HDD Con...

Page 56: ...View Rear View PCB Dimensions 420 4 36 7 2mm Thickness 2mm Layer 8 layers Integrated I O 10 HDD NVMe Connector 5 OCCulink Connector 6 FAN Connector 1 4X2pin Power Connector 1 4Pin Power Connector 2 S...

Page 57: ...Culink Connector OCCulink Connector OCCulink Connector OCCulink Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Con...

Page 58: ...8 GND NC E1 E2 NC VCC3_AUX E3 E4 NC PE_RST_N_R E5 E6 NC PE_CLK_DP E7 E8 PE_CLK_DN GND E9 E10 PE_TX_DP0 PE_TX_DN0 E11 E12 GND PE_RX_DN0 E13 E14 PE_RX_DP0 GND E15 E16 NC PE_TX_DP3 E17 E18 PE_TX_DN3 GND...

Page 59: ...10 HD2_PRS_L HD2_LED P11 P12 GND HD2_VDD12 P13 P14 VDD12 VDD12 P15 GND GND1 GND2 GND SATA8 9 SATA Connector Definition Pin Pin Definition GND 1 2 SAS_TX_DP8 SAS_TX_DN8 3 4 GND SAS_RX_DN8 5 6 SAS_RX_DP...

Page 60: ...Mini SAS Connector Definition Pin Pin Definition GND A1 A2 SAS_TX_DP0 SAS_TX_DN0 A3 A4 GND SAS_TX_DP1 A5 A6 SAS_TX_DN1 GND A7 A8 SAS_SIO_CLK_A SAS_SIO_END_A A9 A10 GND SMB2_CLK3 A11 A12 GND SAS_TX_DP2...

Page 61: ...SCLOCK P3V3_AUX 9 10 HD_ERROR_LED PW2 Power Connector Definition Pin Pin Definition VDD_12V_RUN 1 2 GND GND 3 4 VDD_5V_RUN J7 Front Panel Connector Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH...

Page 62: ...14 B14 PEBp2 PEAp2 A15 B15 PEBp2 GND5 A16 B16 GND17 PEAn3 A17 B17 PEBp3 PEAn3 A18 B18 PEBp3 GND6 A19 B19 GND18 A20 A20 B20 B20 A21 A21 B21 B21 GND7 A22 B22 GND19 PEAn4 A23 B23 PEBp4 PEAn4 A24 B24 PEBp...

Page 63: ...Solid OFF Identify Locate the HDD Blinking 1Hz OFF Rebuild Blinking 4Hz OFF B8026G62FE10HR HDD Status ODn0 Act ODn1 Locate ODn2 Fail Activity LED Color Green Status LED Color Amber Drive not Present x...

Page 64: ...he Front Panel Board Follow these instructions to replace the M1716G75 FPB Front Panel Board 1 Unscrew the front panel tray 2 Pull the front panel tray forwards 4 Disconnect the control cable and USB3...

Page 65: ...http www tyan com 65 5 Unscrew the front panel board from the front panel tray for a new one 6 Reinstall the Front Panel Board into the chassis following the steps in reverse...

Page 66: ...Panel Board Features Front View Rear View Form Factor 28 x 35 4 x 1 6 mm 4 layer PCB Specifications I O 2 USB3 0 Port LED Indicators 1 HDD LED 1 Warning LED 2 LAN LED 1 Power ID LED Switch 1 Reset Bu...

Page 67: ...ation Definition HDD_LED HDD LED BMC_EVENT_LED Warning LED LAN1_LED LAN1 LED LAN2_LED LAN2 LED ID_PW_LED Power ID LED J1 USB3 0 Port J2 USB3 0 Port J3 Reset Button J5 ID Button J6 Power Button J4 USB3...

Page 68: ...er Supply To replace the power supply follow these instructions 1 Located at the power supply usage 2 Free the power from the power socket 3 Replace a new power supply and reinsert it into the power s...

Page 69: ...ore you follow these instructions to replace the M1620G62F D PDB Power Distribution Board 1 Disconnect all the power cables 2 Unscrew to take off the power distribution board and replace with a new on...

Page 70: ...1620G62F D PDB 3 9 2 Connector Definitions M1620 Location Definition J2 J3 PWR1 PW2 PW5 PW3 PW4 PW1 DOM_5V_PW1 DOM_5V_PW2 Power Supply slot Power Supply slot ATX Power 12x2 ATX Power 4x2 ATX Power 4x2...

Page 71: ...PDB Redundant Control Board Form Factor 114 62mm L x 105 6mm W x 28mm H Specifications CON1 CON2 Input connector CON3 Mini fit 24 pin power connector CON4 CON5 HDD 4 pin power connector CON6 PMBus 5 p...

Page 72: ...N DC_GOOD S9 S10 A1 SMBus address 5Vsb S11 S12 5Vsb C_R S13 S14 SGND PRESENT A0 SMBus address S15 S16 B P SIG N A S17 S18 N A N A S19 S20 SGND B P FAIL S21 S22 N A 5Vsb S23 S24 5Vsb CON3 Mini fit 24 p...

Page 73: ...8 PWR OK 5Vsb 9 10 12V 12V 11 12 3 3V 3 3V 13 14 12V SGND 15 16 PS ON SGND 17 18 SGND SGND 19 20 N A 5V 21 22 5V 5V 23 24 SGND CON6 PMBus 5 pin Definition Pin Pin Definition SCL 1 2 SDA SMBAlert 3 4 S...

Page 74: ...After removing all of the aforementioned cables follow these instructions to remove the motherboard from the chassis 1 Disconnect SATA and USB cables 2 Disconnect the power cable and PSMI Cable 3 Dis...

Page 75: ...erboard After removing all of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the nine screws securing the motherboard to the chassis 2 Care...

Page 76: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Page 77: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 4 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Page 78: ...that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS Version It displays BIOS version info...

Page 79: ...Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2005 2099 Months 1 12 Days dependent on month System Time Adjust the system clock HH 24 hours format MM Minutes SS Second...

Page 80: ...Configuration CPU Configuration parameters Onboard Device Configuration Onboard Device and Function Configuration PCIE Slot Configuraion Onboard PCIE Slot Configuration Trusted Computing Trusted Comp...

Page 81: ...on SIO Configuration PCI Subsystem Settings PCI PCI X and PCI Express Settings CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc NVMe Configuration NVMe Device Option...

Page 82: ...tyan com 82 4 3 1 CPU Configuration SVM Mode Enable disable CPU virtulization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related...

Page 83: ...http www tyan com 83 4 3 1 1 CPU0 Information...

Page 84: ...d Active Video Select between onboard or external VGA support Onboard Offboard Onboard LAN B5720 Enable Disable Onboard LAN Device Disabled Enabled LAN1 Port1 OPROM Enable Disable Load Option ROM For...

Page 85: ...MI Button Enable or disable NMI button Disabled Enabled Clock Spread Spectrum Enable Disable CG1_PLL Spread Spectrum Disabled Enabled Serial IRQ Mode Configure Serial IRQ Mode Quiet Continuous 4 3 3 P...

Page 86: ...th Configuration Auto is detected by GPIO x8x8 x16 x4x4x4x4 x8x8 x16 Auto Riser L Down Slot Link Width Configution Setting Pcie Slot Link Width x4x4 x8 Riser R Middle Slot Link Width Configuration Rig...

Page 87: ...k Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser L Middle Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser L Down Slot...

Page 88: ...ed Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will no...

Page 89: ...www tyan com 89 4 3 5 Hardware Health Configuration Auto Fan Control Auto Fan Control help Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus support PMBus Support Disabled Ena...

Page 90: ...90 4 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Page 91: ...http www tyan com 91...

Page 92: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase...

Page 93: ...ial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the...

Page 94: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 95: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 96: ...VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission sp...

Page 97: ...re more than 1 stop bit 1 2 Flow Control Flow Control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Onc...

Page 98: ...esolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST when Bootloader is selected then Legacy Console Redirection is disabled before booting to le...

Page 99: ...r OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Page 100: ...en sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses t...

Page 101: ...e Serial Port 1 View and Set Basis properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode Active Serial Port 2 View and Set Basis properties of the SIO Logical device...

Page 102: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5...

Page 103: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5...

Page 104: ...vices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option Enable or Disable Single...

Page 105: ...http www tyan com 105 4 3 9 1 PCI Express Subsystem Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes...

Page 106: ...etwork Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution...

Page 107: ...http www tyan com 107 4 3 11 NVMe Configuration...

Page 108: ...http www tyan com 108 4 3 12 SATA Configuration...

Page 109: ...abled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Suppor...

Page 110: ...vice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Page 111: ...tyan com 111 4 4 Chipset Menu SMT Mode simultaneous multithreading OFF 1T single thread Auto 2T two thread if capable off Auto North Bridge North Bridge Parameters Error Management Error Management s...

Page 112: ...http www tyan com 112 4 4 1 North Bridge Configuration Memory Configuration Memory Configuration Socket 0 Configuration View Information related to Socket 0...

Page 113: ...http www tyan com 113 4 4 1 1 Memory Configuration Memory Clock This option Allows User to select different memory Clock Default value is 2400 MT s Auto 1333MHz 1600MHz 1866MHz 2133MHz 2400MHz 2667MHz...

Page 114: ...http www tyan com 114 4 4 1 2 Socket 0 Information...

Page 115: ...ble PFEH cloak individual banks and mask deferred error interrupts from each bank Disabled Enabled NOTE The item Platform First Error Handling must be set up to Enabled the following item will appear...

Page 116: ...http www tyan com 116 4 5 AMD CBS Menu...

Page 117: ...Submenu Core Performance Boost Allows Core Performance Boost CPB to be forced to disabled Disabled Auto Global C state Control Controls IO based C state generation and DF C states Disabled Enabled Aut...

Page 118: ...http www tyan com 118 4 5 1 1 Core Thread Enablement Submenu...

Page 119: ...ubmenu Downcore control Sets the number of cores to be used Once this option has been used to remove any cores a POWER CYCLE is required in order for future selections to take effect TWD 1 1 TWD 2 0 T...

Page 120: ...terleaving Controls fabric level memory interleaving AUTO none channel die socket Note that channel die and socket has requirements on memory populations and it will be ignored if the memory doesn t s...

Page 121: ...http www tyan com 121 4 5 3 UMC Common Options Submenu...

Page 122: ...http www tyan com 122 4 5 3 1 DDR4 Common Options Submenu...

Page 123: ...www tyan com 123 4 5 3 1 1 Common RAS Options Submenu Data Poisoning Enable disable data poisoning UMC_CH EccCtrl UcFatalEn UMC_CH EccCtrl WrEccEn Should be enabled disabled together Disabled Enabled...

Page 124: ...1 1 1 ECC Configuration Submenu DRAM ECC Symbol Size DRAM ECC Symbol Size x4 x8 UMC_CH EccCtrl EccSymbolSize X4 x8 Auto DRAM ECC Enable Use this option to enable disable DRAM ECC Auto will set ECC to...

Page 125: ...http www tyan com 125 4 5 3 2 Security Submenu Data Scramble Data scrambling DataScrambleEn Enabled Disabled Auto...

Page 126: ...Submenu Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0 Disabled Auto BankGroupSwap This is an advanced performance setting specifies if the system should use...

Page 127: ...terminism settings power performance Auto Power Perfomance cTDP Control Auto Use the fused cTDP Manual User can set customized cTDP Manual Auto ACS Enable Supported functions of Access Control Service...

Page 128: ...http www tyan com 128 4 5 4 1 NB Configuration Submenu IOMMU Enable Disable IOMMU Disabled Enabled Auto...

Page 129: ...http www tyan com 129 4 5 4 FCH Common Options Submenu...

Page 130: ...http www tyan com 130 4 5 4 1 Ac Power Loss Options Submenu Restore Ac Power Loss Select Ac Loss Control Method Power Off Power On Last State...

Page 131: ...mer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing R...

Page 132: ...sabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled...

Page 133: ...boot Enabled Disabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI...

Page 134: ...http www tyan com 134 4 6 2 BMC Network Configuration Submenu...

Page 135: ...y BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Configure IPV4 support Management Port 2 Enable Disable BMC Share NIC Disabled Enabled Configure IPV6 sup...

Page 136: ...trator Password Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Sec...

Page 137: ...rolled System mode is User Deployed and CSM function is disabled Enabled Disabled Secure Boot Mode Secure Boot mode selector Custom mode enables users to change Image execution policy and manage secur...

Page 138: ...o User Mode install all Factory Default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Autorized Signature Database db Platform Key PK Enroll Fa...

Page 139: ...ertificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mix...

Page 140: ...t External Mixed Test OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin...

Page 141: ...0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless...

Page 142: ...http www tyan com 142 Boot Option Priorities Boot Option 1 Sets the system boot order Device Name Disabled Delete Boot Option Remove an EFI boot option from the boot order...

Page 143: ...http www tyan com 143 4 8 1 Delete Boot Option Configuration Delete Boot Option Sets the system boot order Device Name Select one to Delete...

Page 144: ...it Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Sa...

Page 145: ...Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup opti...

Page 146: ...e motherboard A table of BIOS Temp sensor name explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the t...

Page 147: ...http www tyan com 147 NOTE The system temperature is measured in a scale defined by AMD not in Fahrenheit or Celsius BIOS Temp Sensor Name Explanation...

Page 148: ...hest temperature of CPU0 D1UMC0 channel A slot P0_D1_UMC1_CH_B The highest temperature of CPU0 D1 UMC1 channel B slot P0_D0_UMC1_CH_C The highest temperature of CPU0 D0 UMC1 channel C slot P0_D0_UMC0_...

Page 149: ..._4 Fan speed of SYS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS_FAN_9 SYS_FAN_1...

Page 150: ...o install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7106 X557 2T2E 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis...

Page 151: ...ut the IO plate for LAN card Use a screwdriver to break the LAN port s semi shearing Break one semi shearing if a single port LAN card is installed Break both for a dual port LAN card 5 Insert the IO...

Page 152: ...http www tyan com 152 7 Insert the LAN card into the OCP slot...

Page 153: ...http www tyan com 153 8 Secure the LAN card to the chassis...

Page 154: ...n4 FAN5 2 FP Control Cable and USB Cable M1716G75 FPB Control Board to S8026 MB M1716G75 FPB Connect to S8026 FP Ctrl Cable J4 FPIO_1 USB Cable J7 USB3_FPIO1 3 OCulink Cable SATA Cable FAN Ctrl Cable...

Page 155: ...7 Fan Ctrl Cable J29 FAN_HD1 4 Power Cables TD15 0128 02 PDB to S8026 MB TD15 0128 02 Connect to S8026 2x12P Cable CON3 PW1 2x4P Cable CON7 PW3 PSMI Cable CON6 PSMI1 TD15 0128 02 PDB to M1274 Backplan...