background image

D-307164 MP-902 PG2 Installation instructions

1

1. Overview

The MP-902 PG2 is a smart, wireless outdoor curtain PIR detector with
anti-masking. It is supported by the PowerMaster alarm system and uses
PowerG two-way communication protocol.

The detector has the following features:

l

l

l

l

l

l

l

l

l

l

l

l

l

l

Two

 

channel

 

Pyro

 

(patented)

 

thermal

 

sensor

 

output

 

Microprocessor-controlled

 

temperature

 

compensation

White

 

light

 

protection

Adjustable

 

pet

 

immunity

 

selector

 

with

 

three

 

options:

 

no

 

pet,

 

a

 

small

 

pet

 

weighing

 

less

 

than

 

3

 

kg

 

or

 

6.6

 

lb,

 

or

 

a

 

pet

 

weighing

 

less

 

than

 

18

 

kg

 

or

 

40

 

lb.

Adjustable

 

detection

 

sensitivity

Parabolic

 

and

 

elliptical

 

optics

 

(patented)

Target

 

Specific

 

Imaging™

 

(TSI)

 

technology

 

distinguishes

 

between

 

humans

 

and

 

pets

 

weighing

 

up

 

to

 

18

 

kg

 

or

 

40

 

lbs

True

 

Motion

 

Recognition™

 

algorithm

 

(patented)

 

distinguishes

 

between

 

the

 

true

 

motion

 

of

 

an

 

intruder

 

and

 

any

 

other

 

disturbances

 

which

 

may

 

cause

 

false

 

alarms.

Cross-direction

 

detection:

 

both

 

directions,

 

left

 

to

 

right,

 

and

 

right

 

to

 

left.

 

Active

 

smart

 

anti-masking

 

ability

 

recognizes

 

spray

 

and

 

dust

 

(patented)

 

No

 

vertical

 

adjustment

 

is

 

needed.

Long-life

 

battery

 

which

 

is

 

due

 

to

 

the

 

ultralow

 

current

 

consumption

 

Front

 

and

 

back

 

tamper

 

protection

 

(patented)

Supports

 

temperature

 

and

 

light

 

level

 

reports

 

according

 

to

 

the

 

PowerG

 

panel

 

version

Note:

 For UL installations, only use the device with UL listed control units.

Figure 1: MP-902 PG2

1. Bracket

2. Detector

3. Indication LED

4. PIR optical window

2. Installation advice

Qualified service persons only can install the MP-902 PG2. Before you install the device, consider the following points:

l

Install the MP-902 PG2 according to the Standard for Installation and
Classification of Burglar and Holdup Alarm Systems, UL 681.

l

Mount the detector so that the expected movement of the intruder will
cross the PIR beam.

l

Mount the device on a vertical surface and as straight as possible.

l

Mount the device upright. See Figure 2.

l

Direct the detector at a stable surface, such as a wall or fence, to
provide a curtain detection boundary for better detection.

l

Mount the device at a height that agrees with your pet immunity
preference. See

Setting the pet immunity

for more information.

l

Consider weather conditions that can trigger false alarms, such as
moving tree branches or leaves, and other related environmental
conditions

l

Locate the device at least 20 cm from all persons during normal
operation to comply with FCC and ISED Canada RF exposure
compliance requirements

l

Install the device over sloped ground. See Figure 3.

l

Install the device close to tree branches as weather conditions can
cause movement, resulting in false alarms

l

Install the device in hazardous locations

l

Install the device in areas with a pollution degree higher than pollution
degree 2

l

Install the device in circuits above overvoltages category II

l

Obscure the field of view of the detector

l

Co-locate or operate the antennas used for this product in conjunction
with any other antenna or transmitter

l

Mount the device on surfaces where surface vibration can occur

Figure 2: 

Mounting orientation

Figure 3: Flat ground installation

MP-902 PG2

Wireless outdoor curtain PIR detector with anti-masking and pet immunity

Installation instructions

Do:

Do

 

 

not:

Summary of Contents for MP-902 PG2

Page 1: ... 902 PG2 Before you install the device consider the following points l Install the MP 902 PG2 according to the Standard for Installation and Classification of Burglar and Holdup Alarm Systems UL 681 l Mount the detector so that the expected movement of the intruder will cross the PIR beam l Mount the device on a vertical surface and as straight as possible l Mount the device upright See Figure 2 l...

Page 2: ...et to the mounting surface with screws See Figure 6 5 Insert the batteries into the detector and close the battery cover For more information see Inserting or replacing the batteries 6 Insert the top of the detector into the bracket As you insert the detector choose a slot in the bracket that positions the detector to cover the area that requires protection See Figure 7 and Figure 8 Note When you ...

Page 3: ...ation instructions as described in Table 2 Table 2 Modifying the device Option Configuring instructions Alarm LED Activate or deactivate the alarm LED indication Optional settings LED ON default and LED OFF PIR range Select one of the three ranges according to your installation preference See Setting the detector range Outdoor anti mask Enable or disable the outdoor anti masking feature Optional s...

Page 4: ...erts VERY HOT COLD FREEZING and FREEZER Table 3 describes the temperature configuration setting options Table 3 Temperature configuration settings Option Configuring instructions Threshold Displays the last saved threshold value To change the default value click the back or next button to decrease or increase the value and click OK Disable Enable Defines whether or not the panel will report an ale...

Page 5: ... old batteries and insert the batteries with the and symbols matching the illustration found in the battery compartment See Number 2 in Figure 15 4 Optional To activate the batteries of a new device pull the battery tab while holding the batteries in place with your thumb See Figure 16 5 To close the battery compartment insert the bottom section of the battery cover first and then press and hold t...

Page 6: ...d do not expect other pets or rodents to enter the protected area set the pet immunity selector to Setting 4 and mount the detector at a height of 1 6 m 5 25 ft to 2 m 6 56 ft The best mounting height for this setting is 2 m or 6 56 ft l If you have a small pet that weighs less than 3 kg or 6 6 lb or if there are rodents in the area set the pet immunity selector to Setting 2 and mount the detector...

Page 7: ...llation guide l The MP 902 PG2 can be configured to detect movement with the following settings Left to right Right to left and Both For more information see the alarm direction setting in Modifying the device Table 5 Walk test signal strength indication LED response Reception 3 Green blinks Strong 3 Orange blinks Good 3 Red blinks Poor No blinks No communication 9 LED operation Table 6 provides t...

Page 8: ...Pet configurations l Setting 1 Pet 18 kg or 40 lbs default l Setting 2 Small pet 3 kg or 6 6 lb or rodents l Setting 3 No function l Setting 4 No pet WIRELESS Frequency Europe and rest of world 433 434 MHz 868 869 MHz USA and Canada 912 919 MHz Note Only devices in frequency band 915 MHz are UL ULC listed Max Tx power 10 dBm 433 MHz 14 dBm 868 MHz Communication protocol PowerG Supervision Signals ...

Page 9: ...urs de son fonctionnement normal Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi...