0413 IH-3934

H-3934, H-3935

ELECTRIC LIFT TABLE

1-800-295-5510

 uline.com

π

TECHNICAL INFORMATION

SAFETY GUIDELINES

SPECIFICATIONS

H-3934

H-3935

Weight Capacity

2,000 lbs.

2,000 lbs.

Min. Table Height

8⁄"

8⁄"

Max. Table Height

38⁄"

38⁄"

Travel

30"

30"

Platform Width

28"

36"

Platform Length

48"

48"

Base Frame Width

24⁄

"

24⁄

"

Base Frame Length

49

"

49

"

Weight

402 lbs.

416 lbs.

Sound Pressure Level

<70dB(a)

<70dB(a)

Operating Environment

Indoors

Indoors

WARNING! Do not operate this lift table unless 
you have been trained to use it, authorized 
to do so and have checked that it is in good 
condition. The operator should read all of the 
warning signs and instructions here and on the 
lift table before using it. 

1.  DO NOT concentrate the load at one point on the 

platform or pallet. ALWAYS uniformly distribute each 

layer of load over the supporting surface. 

2.  DO NOT use the lift for any purpose other than its 

intended use.

3.  DO NOT install the lift table on an unlevel or soft 

surface. The lift base frame must be supported 

along its entire length and width. Failure to 

completely support the base frame could result in 

damage to the lift.

4.  DO NOT use the lift table with an unstable, 

unbalanced or loosely stacked load. Unbalanced 

loads may become unstable and fall. SEVERE 

PERSONAL INJURY and PROPERTY DAMAGE may result. 

 

5.  DO NOT overload the lift table. ALWAYS stay within 

the designated capacity ratings. SEVERE PERSONAL 

INJURY and PROPERTY DAMAGE could result.

6.  SHEARING HAZARD. ALWAYS keep hands and feet 

clear of the scissor mechanism and all moving 

components. DO NOT put hands or fingers under 

the platform when in use. SEVERE PERSONAL INJURY 

could result.

7.  CRUSHING HAZARD. ALWAYS keep hands and feet 

clear of all moving components. DO NOT put feet 

on the base frame when in use. SEVERE PERSONAL 

INJURY could result.

8.  PINCH POINT HAZARD. ALWAYS keep feet, hands and 

fingers away from the underside of the platform and 

all moving components. SEVERE PERSONAL INJURY 

could result.

9.  DO NOT change the relief valve setting. The relief 

valve is installed to protect the operator and the 

lift table. Changing the relief valve setting may 

compromise the performance and safety of the lift. 

SEVERE PERSONAL INJURY and PROPERTY DAMAGE 

could result.

Platform Length

Platform 

Width

Base

Width

Raised

Height

Lowered

Height

Travel

Base Length

Summary of Contents for H-3934

Page 1: ...letely support the base frame could result in damage to the lift 4 DO NOT use the lift table with an unstable unbalanced or loosely stacked load Unbalanced loads may become unstable and fall SEVERE PE...

Page 2: ...uthorized modifications to this lift table its hydraulic power unit or its control system may compromise the performance and safety of the system UNDER NO CIRCUMSTANCES should you attempt any repair o...

Page 3: ...r operating instructions See Page 5 rotate the maintenance bars into the maintenance position CAUTION DO NOT lower the lift to engage the maintenance bars at this time 6 Using a forklift position the...

Page 4: ...acity of the lift Refer to the capacity decal on the end of the lift platform 2 If required raise the platform to a convenient working height 3 Uniformly distribute the load over the platform or suppo...

Page 5: ...t the maintenance bars 4 Release the DOWN button ALWAYS check the position of both maintenance bars before going under the platform or servicing the lift DISENGAGE THE MAINTENANCE BARS 1 Depress the U...

Page 6: ...t shaped object into the top of the reservoir opening Reinstall the reservoir breather 9 Finally raise the lift and disengage the maintenance bars by returning them to their stored position CHANGING T...

Page 7: ...en Fill reservoir Reduce load Check lower control for malfunction Clean and or replace lowering solenoid Platform will not remain elevated Lower valve held open Pump check valve not seated Check lower...