OPERATOR’S MANUAL

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ THIS SECTION.

IMPROPER USE  WILL VOID THE WARRANTY.

March 2007

Always use a defoamer when foaming occurs to prevent vacuum motor damage.

Never use water above 130

°

 F (54

°

C).

Do not use outdoors or where temperature is below freezing.  Protect your machine
from any extremes in temperatures.

Do not let the pump run dry. Turn the pump off and refill the tank when cleaning solution
gets low.

Flush the machine with an acid de-scaler regularly (monthly or more often) to prevent
a build-up of minerals or chemicals in the pump and heat systems.  Follow the flush
with a clear water rinse to remove any particles and to rinse the acid from the machine.

Use approved chemicals only. All chemicals should be mixed thoroughly.  Liquid
chemicals are recommended to prevent powder buildups. A pH between 6 and 9 is
recommended.  The use of high alkaline detergents or strong acids will accelerate the
wear of the pump and seals, and will void the warranty.

All extension cords must have a rating of at least 12/3 (#12 cord). Extension cords
should be no longer than 50 feet.  Replace the plug immediately if the ground prong
becomes damaged or is broken off.

Summary of Contents for COBRA-C2

Page 1: ...er regularly monthly or more often to prevent a build up of minerals or chemicals in the pump and heat systems Follow the flush with a clear water rinse to remove any particles and to rinse the acid f...

Page 2: ...sure to go to www usproducts com to register your warranty on line Do not leave the maching unattended when it is plugged in Unplug the unit from the outlet when not in use and before servicing To avo...

Page 3: ...float Shut OFF can also be accessed through this opening for maintenance Vacuum Inlet 5 This is where the vacuum hose attaches to the machine Latch 6 Open the latches to access the base compartment w...

Page 4: ...n the recovery tank any time foaming occurs 8 Monitor the water level in the solution tank Do not let the pump run dry 9 When the solution tank gets low turn off the pump fill the solution tank empty...

Page 5: ...ower to pump Test the switch Test the pump motor Partially clogged solution path hose heater tool Worn pressure switch in pump Adjust pressure sensor in pump head Debris plugging cleaning tool or vacu...

Page 6: ...7 9 12 10 15 17 18 18 3 20 25 21 22 40 41 42 43 44 45 46 47 48 49 58 50 51 52 62 69 14 16 66 COBRA C2 230 March 2007 19 56 11 12 13 14 30 61 60 59 58 69 57 55 54 53 29 64 56 1 6 5 3 2 4 8 22 23 30 30...

Page 7: ...p t 26 91 Elbow brass 1 4 n p t 27 2012 Hose 66 cm 28 108 Elbow Hose barb 29 925 Hose pump inlet 30 166 Hose Clamp 34 2017 Pump 100 psi 230V 40 270 Bolt 1 4 20 X 12 7 cm 41 137 Washer split lock 42 1...

Page 8: ...8 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com NOTES COB C2 230CEN A...