1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.

2. Keep machine from rain and snow, extremes in temperatures, and store in a

heated location.  Use the machine indoors.  Do not use outdoors.

3. Do not let the pump run dry.

4. Use approved chemicals only.  NO SOLVENTS.

5. Wear gloves or use rags when removing quick disconnects to prevent burns.

6. Keep machine from rain and snow, from extremes in temperatures, and store it in a

heated location. Use the machine indoors. Do not use outdoors.

6.5.2007

Summary of Contents for KING COBRA 300

Page 1: ...motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemical...

Page 2: ...ed into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cor...

Page 3: ...not covered by the warranty MAINTENANCE For optimum performance flush the machine with clear water at the end of each working day Once a month minimum run a flushing compound through the machine to br...

Page 4: ...tor _____________________________________ 7 1 Inspect the machine hoses and cleaning tools for cleanliness and completeness 2 Fill the solution tank with water Using warm water may be a benefit in cle...

Page 5: ...k 15 When finished with the job remove any unused solution from the solution tank and run a few gallons of clean water through the system Drain the recovery tank by placing the dump hose over a drain...

Page 6: ...61 59 62 65 66 67 45 78 U S PRODUCTS 68 69 71A 73 75 75A 71 70 76 74 72 80 39 36 35 34 29 33 32 31 38 1 9 7 11 12 6 T O I T E M 4 6 10 15 19 77 47 14 20 16 22 17 8 18 21 T O I T E M 4 6 48 53 49 27 4...

Page 7: ...m control 120V FP225A PCB vacuum control 240V 50 2B1 Screw 6 32 X 2 1 4 51 2014 Fan cooling 120V 2018 Fan cooling 240V 51A 2015 Guard fan 52 908A Latch draw rubber 53 928 Louver 3 includes 3 screws 54...

Page 8: ...ranty 7 2 3 stage Electronic Positive displacement 300 psi carpet 140 Fully adjustable to 212 F 2000 Watts Stainless steel double bend twin tip 122 lbs SPECIFICATIONS 208 772 0573 800 257 7982 FAX 208...

Reviews: