background image

User Manual 

 

 

 

HOT DISPLAY CABINET 

HT-Series 

 

Summary of Contents for HT 1100

Page 1: ...User Manual HOT DISPLAY CABINET HT Series ...

Page 2: ......

Page 3: ... 6 3 Introduction 8 3 1 Introduction 8 3 2 Special features 8 3 3 Technical details 9 4 Installation and putting into operation 12 4 1 Unwrapping 12 4 2 Installation 12 4 3 Electrical connection 12 4 4 Preparation of Using Starting up 13 5 Operation 14 5 1 Operation elements 14 5 2 Operation 14 5 3 Optional 15 6 Maintenance 16 6 1 Cleaning and care 16 6 2 Trouble shooting 18 6 3 Wiring Diagrams 19...

Page 4: ...be examined regularly 2 1 3 Obligation of the personnel All induviduals who are authorized to work with the unit are obliged to pay attention to the fundamental regulations of work safety and accident avoiding read the chapter on work safety and warning notes in this manual and to confirm through their signature that they have understood these before actually operating the unit 2 1 4 Possible risk...

Page 5: ...ce of wear and tear parts Unauthorized repair Force of nature and act of god 2 3 Symbols and Notes In the operating manual the following symbols and signs are used This symbol means a possibly or directly threatening danger for the life and the health of persons and or a possibly dangerous situation Ignoring of these references may result in consequences for your health and or can lead to property...

Page 6: ...determined clearly for installing start up operation assembling and servicing of the unit During instruction the personal may only work at the unit under supervision of an experienced person 2 5 4 Unit control Only instructed personal is allowed to operate the controls 2 5 5 Safety during regular operation The unit is only to operate if all protective devices are fully workable At least once per s...

Page 7: ...t unintended reclosing Check all screw connections for tight fitting After finishing maintenance check all safety devices for proper functionality 2 5 9 Structual changes to the unit Do not perform any changes extensions or conversions to the unit without the manu facturers permission especially welding work at supporting parts For all conversions a written permission of the company UBERT GASTROTE...

Page 8: ...The optimized constant climate guarantees long holding times at low quality loss To optimize the product presentation the cabinet is equipped with an effective hallogen lighting The maximum holding time depends on the kind of product and on the products starting temperature It might be limited by national or local regulations Never equip the cabinet with cold or deep frozen products 3 2 Special fe...

Page 9: ...Introduction 9 printed 02 2015 Subject to change TopLineUserManualHT docx 3 3 Technical details 3 3 1 Dimensions mm HT 700 HT 700 DB HT 100 HT 1100 DB ...

Page 10: ...er HT 700 230V 1 N 50Hz 2 8 kW HT 1100 400V 3 N 50Hz 4 2 kW HT 1400 400V 3 N 50Hz 5 6 kW HT 700 DB 230V 1 N 50Hz 2 82 kW HT 1100 DB 400V 3 N 50Hz 4 23 kW HT 1400 DB 400V 3 N 50Hz 5 63 kW HT 700 2 208V 240V 1 N 60Hz 2 4 kW HT 1100 2 208V 240V 3Ph 1 N 60Hz 3 6 kW HT 1400 2 208V 240V 3Ph 60Hz 4 8 kW HT 700 2 DB 208V 240V 1 N 60Hz 2 4 kW HT 1100 2 DB 208V 240V 3 N 1 N 60Hz 3 6 kW HT 1400 2 DB 208V 240...

Page 11: ...Introduction 11 printed 02 2015 Subject to change TopLineUserManualHT docx all types 70 dB A ...

Page 12: ... service technicians of the company UBERT GASTRO TECHNIK GMBH or service technicians of your responsible service partner are al lowed to perform el connection and other service All national and lokal rules and regulations concerning electricity fireprotection and the like have to be concidered During any servicing take care that the unit is disconnected from the mains Not pay ing attention may res...

Page 13: ...Cabinet you have to clean all removable parts carefully with a grease sol vent Note Do not use flammable cleaners Do not use high pressure water pressure or steam jet cleaning machines You will have further information about this in the sec tion cleaning and upkeeping After cleaning the Hot Cabinet properly the smell will be minimal when using it the first time ...

Page 14: ...es the cabinet ON and OFF LIGHT Button Switches the lights inside the cabinet ON and OFF PPROGRAMMING button Keep pushed to change the set temperature using and UP button While is pushed use the UP button to increase the set tempera ture DOWN Button While is pushed use the DOWN button to decrease the set tem perature Also used to quit alarms HEATING Symbol Is illuminated whenever the actual temper...

Page 15: ...e the tools you require during operation Cutting Board Workspace to cut your products and do various other han dling during loading unloading packing and the like Note Do not place hot GN pans or other hot items on the cutting board 5 3 Optional Cutting Board To cut your products and do various other work during loading unload ing packing and the like Note Do not place hot GN pans or other hot ite...

Page 16: ...rwards so that there are no residues of the cleaner on these parts It is absolutely necessary to watch out for some fundamental things to keep this longliving high grade steel machine working always keep the high grade steel surface clean watch out that there is always enough fresh air on the surface never contact the surface with rusty material never use bleaching or chlorine cleaners Take brushe...

Page 17: ...below some special cleaning tips for this specific unit Lamps To be cleaned only with soft paper or cloth and alcohol Glass Tip the cuved front glass to clean the inside Remove dust and dirt from the glass surface with soft cloth to avoid scratches Drawers GN Pans Easily removable without tools for separate cleaning ...

Page 18: ...these two companies are allowed to carry out service work and replacement of defect parts If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid Checklist for your Hot Cabinet 1 Is the unit wired properly and connected to the mains 2 Does the wall socket provide the required current voltage see the nameplate for details 3 Does the f...

Page 19: ...Maintenance 19 printed 02 2015 Subject to change TopLineUserManualHT docx 6 3 Wiring Diagrams 6 3 1 HT 700 230V 1 N 50Hz 6 3 2 HT 700 DB 230V 1 N 50Hz ...

Page 20: ...20 Maintenance printed 02 2015 Subject to change TopLineUserManualHT docx 6 3 3 HT 1100 400V 3 N 50Hz 6 3 4 HT 1100 DB 400V 3 N 50Hz ...

Page 21: ...Maintenance 21 printed 02 2015 Subject to change TopLineUserManualHT docx 6 3 5 HT 1400 400V 3 N 50Hz 6 3 6 HT 1400 DB 400V 3 N 50Hz ...

Page 22: ...22 Maintenance printed 02 2015 Subject to change TopLineUserManualHT docx 6 3 7 HT 700 2 UL 230V 1 N 50Hz 6 3 8 HT 700 2 DB UL 230V 1 N 50Hz ...

Page 23: ...Maintenance 23 printed 02 2015 Subject to change TopLineUserManualHT docx 6 3 9 HT 1100 2 UL 400V 3 N 50Hz 6 3 10 HT 1100 2 DB UL 400V 3 N 50Hz ...

Page 24: ...24 Maintenance printed 02 2015 Subject to change TopLineUserManualHT docx 6 3 11 HT 1400 2 UL 400V 3 N 50Hz 6 3 12 HT 1400 2 DB UL 400V 3 N 50Hz ...

Page 25: ...ied out only by their service personal or by your authorized Service companies If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid Also all certifications CE UL NSF and the like become invalid 6 4 1 Explosion Diagramm HT and HT DB are almost the same The only difference is the part 25 It is the front screen on HT and the Dia Boar...

Page 26: ...w 121044 1 17 drawer 120520 1 1 18 crumb tray 120611 2 19 tumber switch 341108 2 20 thermometer 0 C to 120 C HT700 HT700DB 342907 1 20 thermometer 30 F to 250 F HT700 2 HT700 2DB 342912 1 21 knob 361311 1 22 display 360146 1 23 thermostat 342209 1 24 transverse current fan 618A HT700 HT700DB 344104 1 24 transverse current fan 618A HT700 2 HT700 2DB 344101 1 25 front screen HT700 HT700 2 120519 1 1...

Page 27: ...rawer 120552 1 1 18 crumb tray 120612 2 19 tumber switch 341108 1 20 thermometer 0 C to 120 C HT1100 HT11000DB 342907 20 thermometer 30 F to 250 F HT1100 2 HT11000 2DB 342912 1 21 knob 361311 1 22 display 360146 1 23 thermostat 342209 1 24 transverse current fan 618A HT1100 HT1100DB 344104 1 24 transverse current fan 618A HT1100 2 HT110 2DB 344101 1 25 front screen HT1100 HT100 2 120551 1 1 25 Dia...

Page 28: ...28 Maintenance printed 02 2015 Subject to change TopLineUserManualHT docx ...

Page 29: ...b tray left right 120613 2 18 crumb tray middle 120614 1 19 tumber switch 341108 2 20 thermometer 0 C to 120 C HT1400 HT1400DB 342907 1 20 thermometer 30 F to 250 F HT1400 2 HT1400 2DB 342912 1 21 knob 361311 1 22 display 360146 1 23 thermostat 342209 1 24 transverse current fan 618A HT1400 HT1400DB 344104 2 24 transverse current fan 618A HT1400 2 HT1400 2DB 344101 2 25 front screen Mr Pick 120581...

Page 30: ...30 Maintenance printed 02 2015 Subject to change TopLineUserManualHT docx ...

Page 31: ...e 5A 335091 HT 700 2 DB 335091 HT 1100 2 DB 335091 HT 1400 2 DB terminal block 333323 HT 700 2 DB 333323 HT 1100 2 DB 333323 HT 1400 2 DB end cap for terminal block 333324 HT 700 2 DB 333324 HT 1100 2 DB 333324 HT 1400 2 DB ballast 340630 HT 700 2 340632 HT 1100 2 340632 HT 1400 2 ballast 340631 HT 700 2DB 340633 HT 1100 2DB 340633 HT 1400 2DB high limit switch 341160 HT 700 2 DB 341160 HT 1100 2 ...

Page 32: ...32 Maintenance printed 02 2015 Subject to change TopLineUserManualHT docx 6 5 Declaration Of Conformity ...

Reviews: