background image

 
 

 

 

CX2162/66 

Clex private  
Compact electronic knob cylinder 

Operating and 

assembly manual 

 

Summary of Contents for CX2162

Page 1: ...CX2162 66 Clex private Compact electronic knob cylinder Operating and assembly manual...

Page 2: ...r 2 4 97297 Waldbuettelbrunn Germany Phone 49 931 40672 0 Mail contact UundZ de http www UundZ com This operating and assembly manual is copyright protected The information contained this manual shoul...

Page 3: ...4 1 General assembly instructions 11 4 2 Assembly 11 5 Commissioning 12 5 1 Initial commissioning 12 5 2 Programming the service key 13 5 3 Management as programming clearing system 13 5 4 Management...

Page 4: ...mbH does not assume any responsibility for disruptions or hazards such as non access to injured personnel malfunctions property damage or other damages resulting from non compliance with this operatin...

Page 5: ...locks The applicable regulations should be followed The CX216x should not be used if the housing or the electronics is damaged Changes or retrofits to the product are not allowed The knob module shou...

Page 6: ...ble and audio signal when the battery power reduces capacity loss during the final 1 000 operations of the battery see chapter 7 2 1 Battery Replacement Signalling happens in three phases The battery...

Page 7: ...ines The event log can be read via the CX2530 Keyng 3 1 3 Locking time1 The locking time defines how long the knob module remains connected after scanning an authorised key A value of 1 second to 15 s...

Page 8: ...6 1 Fixing screw 4 Electronic knob 2 Half cylinder casing 5 Knob cover 3 Battery 3 3 Versions Different versions of the electronic locking cylinder are available for selection For indoor or outdoor us...

Page 9: ...echanical knob 20 0 mm Diameter of the mechanical knob 29 0mm Transponder Version 1 MIFARE MIFARE Classic MIFARE DESFire Active transponder 868MHz Version 2 LEGIC LEGIC prime LEGIC advant MIFARE DESFi...

Page 10: ...T DESCRIPTION 9 3 4 3 Dimensions 3 5 Standards The CX216x knob module conforms to the following standards EN 15684 2013 being prepared EN 60529 2014 being prepared A B 44 3 20 0 29 0 31 4 A 10 44 3 31...

Page 11: ...a programming station 3 6 2 CX6522 wireless stick The Clex wireless stick is required for the basic operation of the Keyng software 3 6 3 CX6520 Programming station The Clex programming station is op...

Page 12: ...always check if the components can move freely After assembly check the function with the door open 4 2 Assembly Insert the cylinder housing along with the electronic knob into the lock Tighten the f...

Page 13: ...battery from discharging during transport the CX6162 66 is kept in transport mode till the initial commissioning There are two options of changing over to the normal operating mode Option 1 Turn the k...

Page 14: ...ionally program additional keys as described in the previous step Hold the service key in front of the reading unit or wait 15 seconds to exit the programming mode To create a key with toggle authoris...

Page 15: ...find more detailed information in the CX2530 Keyng documentation 5 5 Changing the settings The following settings can be adjusted using the CX2530 Keyng software Time Enable disable the event log Loc...

Page 16: ...mes for example by metallic objects in the surroundings without reading a key then automatic wake up is disabled In this case the knob module has to be woken up manually Turn the knob module few times...

Page 17: ...d using the door handle in the unlocked state The time duration for which the knob cylinder remains engaged can be configured 1 to 15 seconds the default value is 5 seconds After successful authorizat...

Page 18: ...art glowing Timer circuit toggling On Long loud beep green LEDs start glowing Timer circuit toggling Off Long loud beep red LEDs start glowing Reset Long low beep all the LEDs are switched on briefly...

Page 19: ...ON Danger of injury caused by improper use Do not charge open or heat the battery Always replace discharged batteries with new batteries Pay attention to the correct polarity when inserting the batter...

Page 20: ...er as far as it goes onto the knob so that the marked spot on the knob cover aligns with the protruding plastic part on the knob The knob cover has to be inserted such that only the rubber seal is vis...

Page 21: ...cover and push it together onto the knob as far as it goes Remove the battery removal tool from the knob cover and check whether it is seated firmly on the knob by pulling the knob cover Check the tim...

Page 22: ...tion Knob cover is removed see chapter 7 2 1Replacing the battery Page 18 The sealing ring is visible once the knob cover is removed It is located on the side facing the door To remove the sealing rin...

Page 23: ...rror 5 long beeps 2 short beeps RTC fault clock 5 long beeps 3 short beeps Internal error unhandled interrupt 5 long beeps 4 short beeps Internal error bus conflict 5 long beeps 5 short beeps Internal...

Page 24: ...POSAL 23 9 Disassembly and Disposal 9 1 Disassembly Loosen the Allen screw of the mechanical knob and remove the mechanical knob from the cylinder Remove the fixing screw Remove the cylinder body and...

Page 25: ...should be in accordance with the European Directive 2002 96 EC at a collection point for electrical waste Defective or used batteries should be recycled in accordance with the European Directive 2006...

Page 26: ...example be an ISO card or a chip The key is sometimes also known as transponder Service unit Data can be exchanged between a PC having the Keyvi management software and the knob cylinder using the ser...