1K HE3 1000LT STORAGE TANK 

  Installation and  

  User Manual

TOP VENT FITTING MUST NOT EXCEED 
300mm ABOVE TANK

Warning: Please read and understand the information in this manual before installing or 

operating the 1K HE3 1000LT Storage Tank unit.

Max Working Pressure 600 kPa Heat Exchange Coils

WaterMark – AS74500 

Caution

DO NOT OBSTRUCT VENT

.  

Install water heater to requirements of AS/NZS3500.4

Summary of Contents for 1K HE3

Page 1: ...ABOVE TANK Warning Please read and understand the information in this manual before installing or operating the 1K HE3 1000LT Storage Tank unit Max Working Pressure 600 kPa Heat Exchange Coils WaterM...

Page 2: ...1 NOTICE 3 2 TRANSPORTING THE SOLAR HOT WATER SYSTEM 4 3 GENERAL 5 4 IMPORTANT 6 5 INSTALLATION 8 6 7 WARRANTY CONDITIONS TYPICAL INSTALLATION DIAGRAM 10 12...

Page 3: ...minutes The collectors will become extremely hot and this may result in cracked tubes Before filling for the first time after installation or if refilling after maintenance ensure the collectors are c...

Page 4: ...of the solar hot water system Handle All Cartons With Care When handling the evacuated tube cartons do not stack boxes more than 3 layers high Ensure that all boxes are strapped down in order to preve...

Page 5: ...recommended installing an inline filter before the tempering valve 3 4 gas Boosting The Ultimate Solar Solar Water Heater is compatible with gas boosting including but not limited to the following pr...

Page 6: ...tion and installation manual 4 4 Water Quality The working design of the Ultimate Solar Hot Water System helps protect the inner surface of the stainless steel cylinder because there is not a continuo...

Page 7: ...ended to take a digital camera To the installation side to take photos of the installation during and once completed When loading boxes please take care Ensure that all boxes are strapped down in orde...

Page 8: ...t must be subjected to a head pressure of NO MORE THAN 300MM Heat can be drawn off by upper 2 coils and heat can be added by the lower coil or direct coupled to a boiler loop A 1200mm x 1200mm minimum...

Page 9: ...A A Scale 1 5 1 2 3 4 5 6 NO Name Qty Note 1 2 3 4 5 6 1 40m 1 Copple TP2 40m Copple TP2 40m Copple TP2...

Page 10: ...ill not be covered under warranty Please contact Ultimate Solar for more details This warranty applies only to those components provided as part of the Ultimate Solar Water System and not any third pa...

Page 11: ...em due to impact from any object 3 If the solar collector is left dry ie no liquid circulation and exposed to regular daily sunlight ie not covered for a period exceeding 14 consecutive days 4 The eff...