INSTALLATION AND MOUNTING MANUAL 

 

HyperSpike

® 

MA-Micro 

 

 

 

 

 

Summary of Contents for 90145A-801-02

Page 1: ...Copyright Ultra Electronics USSI Columbia City IN 46725 USA PART NO xxxxxxxxx REV A INSTALLATION AND MOUNTING MANUAL HyperSpike MA Micro ...

Page 2: ...pike MA Micro Installation and Mounting Manual i 90145A MAN MAMICRO Rev A This manual contains information that is proprietary to Ultra Electronics USSI It is intended solely for the education and use of parties operating and maintaining the equipment described herein ...

Page 3: ...n 10 Leads UL 1480A CID2 MA Micro 90145A 801 04 L Gray 10 Leads UL 1480A CID2 MA Micro 90145A 801 02 Tan 10 Leads Uncertified MA Micro 90145A 801 04 Gray 10 Leads Uncertified MA Micro 90145A 802 02 Tan Connector Uncertified MA Micro 90145A 802 04 Gray Connector Uncertified MA Micro Note CID2 UL Class I Division 2 Groups A B C and D outdoor wet listed Specifications Table 1 Emitter Head and dB Rati...

Page 4: ...MOUNTING OUTDOORS MAKE SURE THAT THE SUPPORT SYSTEM USED HAS THE PROPER WIND LOAD RATING AND COMPLIES WITH LOCAL STANDARDS AND CODES The MA Micro comes standard with a mast mount Figure 1 A 10 foot conduit with electrical leads extends from the system The MA Micro is intended to be pole mounted or suspended by the mast mount The unit can be rigidly mounted or hung by the three eyelets 1 To rigidly...

Page 5: ...curing the pipe Tighten the included set screws to 30 in lbs or insert a locking pin through the mast mount and pipe Figure 2 Locking pins are recommended for systems that are suspended by the mast mount Figure 2 Location of screw to tighten to 2 pipe 3 Eyelets have been provided to secure a safety cable to the MA Micro The safety cable is a customer supplied item ...

Page 6: ...ble Routing 3 1 1 Leaded Systems The MA Micro system comes with a 10 foot long 3 4 flexible conduit and 11 foot 14 AWG lead The connection at the end of the conduit requires an installer supplied junction box with a rating suitable for the installation environment of the box See figure 3 for an example Route the conduit to a junction box approved by local electrical codes and standards Follow your...

Page 7: ...hat provides audio to the speaker from the amplifier Figure 4 See section 3 2 2 for the pinout of the connector The mating cable is sold separately Figure 4 Connector Location 3 2 Wiring Diagrams 3 2 1 Leaded Systems The MA Micro has 14 AWG leads coming out of the speaker as depicted below Figure 5 The red black pair is used for attaching to the customer supplied amplifier or the optional HyperSpi...

Page 8: ...nual 90145A MAN MAMICRO Rev A Page 6 3 2 2 Connectorized Systems The connectorized MA Micro has a four pin connector Included with the unit is a speaker cable used to connect the unit to a customer supplied amplifier or the optional HyperSpike amplifier kit Pin A Channel 1 Pin B Channel 1 Pin C N A Pin D N A ...

Page 9: ...ible for transporting your product to our factory We will pay the return shipping charges on all products repaired under warranty 4 1 Failures Not Covered by This Warranty This warranty covers manufacturing defects The warranty DOES NOT cover 1 Damage caused by accident misuse abuse product modification or neglect 2 Damage incurred during shipment you must claim these damages from the carrier 3 Da...

Page 10: ...Ultra Electronics USSI 4868 East Park 30 Drive Columbia City IN 46725 USA 1 260 248 3666 ...