Summary of Contents for Touch UP120AC

Page 1: ...2x120W 2x120W 12A 12A UP120AC INSTRUCTION MANUAL...

Page 2: ......

Page 3: ...and Safety Notes Lithium Battery Connection Diagram Operation Diagram Homepage Operation Diagram Setting Start Complete Lithium Battery Meter System Set up Error Message Warranty and Service TABLE OF...

Page 4: ...is product as it covers a wide range of information on operation and safety INTRODUCTION Input voltage AC 110V or 220V DC 11 0 18 0V 2X120W 240W 2X10W 20W 0 1 12 0A 0 1 5 0A 500mA cell 1 6 series 1 15...

Page 5: ...AC Cooling fan with Temp Sensor Control PC Link Battery Sockets Battery Sockets Temp Sensor DC Input 11 18V PC Link DC Output 5V 2 1A AC Input Voltage Selection Switch INTRODUCTION Balance DC Socket...

Page 6: ...y if the voltage of any single one cell is abnormal Adaptable to Various Type of Lithium Battery UP120AC Touch is adaptable to various types of lithium batteries such as LiPo LiIon and the new LiFe se...

Page 7: ...threshold the process will be terminated automatically Automatic Charging Current Limit You can set up the upper limit of the charging current when charging your NiMH or NiCd battery it is useful for...

Page 8: ...the operating area Make sure you know the speci cations of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery...

Page 9: ...discharging Have you checked the battery voltage Lithium battery packs can be wired in parallel and in series i e a 2 cell pack can be 3 7V in parallel or 7 4V in series Have you checked that all conn...

Page 10: ...at the charge lead should be of adequate conductor cross section and high quality connectors which are normally goldplated should be tted to both ends Always refer to the manual by the battery manufac...

Page 11: ...to protect them Some rechargeable batteries have a memory effect If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their...

Page 12: ...battery it is absolutely essential to check one last time that you have set the charging parameters correctly If the settings are incorrect the battery may be damaged and could even burst into ames o...

Page 13: ...d If in doubt as to which socket to use please ask your dealer for clari cation 5 Start the charge cycle wait and watch that the charger starts to charge and shows correct readings on the screen 6 Whe...

Page 14: ...h you want to use Battery Type selection buttons Select which battery type you want charge SYSTEM System setting safety protection and charger parameter settings are here PROGRAM You can store up to 6...

Page 15: ...the selected one will be highlighted with colour After you con rmed battery type please touch and to set how many cells of your battery to be connected to this charger Please touch to select the opera...

Page 16: ...y charges the battery Note you should set up the upper limit of the charge current to avoid damage by excessive feeding current Some batteries of low resistance and capacity can lead to higher current...

Page 17: ...y at their own risk which allows LIPO and LIFE packs to be charged in excess of recommended cell terminal voltages This is the voltage level that UP120AC Touch will stop discharging the battery and is...

Page 18: ...P TIME STOP GRAPH BATTERY METER BALANCE 23 86V 2 0A 0mAh 34 C 0 C 0 12 06 When the charger is working the users could check the real time status of charging capacity overall voltage and each cell volt...

Page 19: ...b SYSTEM PROGRAM BATT METER The user can check lithium battery s total voltage the highest voltage the lowest voltage and each cell s voltage and can check Nickel and Pb battery s total voltage Touch...

Page 20: ...ing program by touch SYSTEM INPUT LOW REST TIME 1 120 min The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a t...

Page 21: ...starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if the termination circuit cannot detect the battery full The value for the safety tim...

Page 22: ...rect polarity connected The battery is interrupted The Battery connection is wrong The cell number is wrong The internal temperature of the unit goes too high Input voltage less than 11V Input voltage...

Page 23: ...erial or operational defects which are present at the time of purchase During that period we will repair or replace free of service charge for products deemed defective due to those causes You will be...

Page 24: ...Manufactured by Ultra Power Technology Limited www ultrapower hk E mail info ultrapower hk...