Automatic Voltage Regulation (AVR)

Protect your computer from electrical damage caused 
by dangerous "spikes and sags".

$125,000 Limited Warranty

Includes

UPS Monitoring

Software

Uninterrupted 

Power Supply (UPS)

The Ultimate Power Protection!

If you're looking for the most complete, technologically advanced power 
protection unit for the money, the Ultra UPS line is exactly what you need.  An 
Ultra UPS is an absolute must for anyone running a small server, workstation or a 
powerful PC.  You simply cannot afford to cut corners when it comes to 
safeguarding your valuable equipment, and these UPS's deliver the 
comprehensive protection for computer, peripherals and data files at a 
remarkably low price.  

 

Features

    - Line Interactive Design    
    - AVR (Automatic Voltage Regulation)
    - Fully Digitized Microprocessor Controlled
    - Protects up to 4 Devices at Once
    - Energy Saving Function (UPS Green Mode)
    - 50/60Hz Frequency Auto Sensing and Selection
    - USB Communication Port
    - Advanced Battery Management (ABM Technology)

Gneral

Sku
Backup Time

Net Weight Kg (lbs)
Digital Display

Output

Watts
UPS Capacity
No. of Sockets
Voltage (Battery)
Frequency (Battery)
Transfer Time

Input

Voltage (Single Phase)
Frequency

Protection

Unit Input
Overload Protection

Short Circuit
Surge Protection

Battery

Type

Typical Recharge Time
Protection

Interface

USB

Alarm

Battery Backup
Battery Low
Abnormal Charge
Overload

Environment Ambient Operation

1500VA

2000VA

ULT33045

ULT33046

About 60 Minutes

About 65 Minutes

Yes

Yes

900

1200

1500VA

2000VA

Style A UPSx4, Bypassx2

Style A UPSx4, Bypassx2

Simulated square wave output at n/-5%

Simulated square wave output at n/-5%

50 or 60Hz +/- 0.3Hz

50 or 60Hz +/- 0.3Hz

2-4 milliseconds, including detection time

2-4 milliseconds, including detection time

120V +15%/-20% at line input

120V +15%/-20% at line input

50 or 60Hz +/- 10% (auto sensing)

50 or 60Hz +/- 10% (auto sensing)

Circuit breaker for overload & short circuit protection

Circuit breaker for overload & short circuit protection

UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds

UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds

UPS output shuts off immediately

UPS output shuts off immediately

2100 Joules

2100 Joules

Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime

Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime

6 hours (to 90% of full capacity)

6 hours (to 90% of full capacity)

Automatic self-test, Over discharge protection, short 
circuit protection by fuse

Automatic self-test, Over discharge protection, short 
circuit protection by fuse

Battery low detecting, UPS on/off scheduling AC 
input/output power status display.

Battery low detecting, UPS on/off scheduling AC 
input/output power status display.

Slow beeping sound every 4 seconds

Slow beeping sound every 4 seconds

Rapid beeping sound every second

Rapid beeping sound every second

AC Mode: Rapid beeping sound every 0.5 second

AC Mode: Rapid beeping sound every 0.5 second

Continue beeping sound

Continue beeping sound

3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30

͠

3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30

͠

1000VA

1025VA

ULT31502

ULT33044

About 50 Minutes

About 50 Minutes

28.6(63.0)

28.6(63.0)

Yes

Yes

615

615

1025VA

1025VA

Style A UPSx4, Bypassx2

Style A UPSx4, Bypassx2

Simulated square wave output at n/-5%

Simulated square wave output at n/-5%

50 or 60Hz +/- 0.3Hz

50 or 60Hz +/- 0.3Hz

2-4 milliseconds, including detection time

2-4 milliseconds, including detection time

120V +15%/-20% at line input

120V +15%/-20% at line input

50 or 60Hz +/- 10% (auto sensing)

50 or 60Hz +/- 10% (auto sensing)

Circuit breaker for overload & short circuit protection

Circuit breaker for overload & short circuit protection

UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds

UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds

UPS output shuts off immediately

UPS output shuts off immediately

2100 Joules

2100 Joules

Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime

Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime

6 hours (to 90% of full capacity)

6 hours (to 90% of full capacity)

Automatic self-test, Over discharge protection, short 
circuit protection by fuse

Automatic self-test, Over discharge protection, short 
circuit protection by fuse

Battery low detecting, UPS on/off scheduling AC 
input/output power status display.

Battery low detecting, UPS on/off scheduling AC 
input/output power status display.

Slow beeping sound every 4 seconds

Slow beeping sound every 4 seconds

Rapid beeping sound every second

Rapid beeping sound every second

AC Mode: Rapid beeping sound every 0.5 second

AC Mode: Rapid beeping sound every 0.5 second

Continue beeping sound

Continue beeping sound

3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30

͠

3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30

͠