Testing the Alarm
Press and release the test button to test the alarm. The alarm should sound
three times with a flashing red light then stop.
After testing check that the red light flashes approximately every minute. Test
the alarm once a week to ensure correct operation.
WARNING:
The electronic test button provides a full test of the alarm’s
functionality. Do not try to test the alarm using either heat, smoke, or naked
flame as damage will occur.
6. USER INFORMATION
Protect your Home Against Fire
Contact you local Fire Brigade for a home safety check, this information is
free and will identify potential fire hazards in and around your home.
Make sure all occupants of the home know what a fire alarm sounds like.
Prove and practise a fire escape plan and arrange a suitable and safe
assembly point.
What to Do if the Alarms Sound
Alarms sounds are as follows:
Full alarm indicating
smoke and fire
Repeating series of 3 beeps every
4 seconds with flashing light
Low battery
Single beep every minute
Test button jammed
One beep every 11 seconds
Fault
Double beep every minute
Ensure everyone leaves the building as soon as possible.
•
Do not run.
•
Do not stop to collect belongs.
•
If it is safe to do so, close all windows and doors as you escape to
prevent the spread of fire.
•
Smoke is the main cause of death from fire. If trapped inside the building,
cover your mouth, conserve breath and crawl to safety.
Do not silence a fire alarm until you know the cause of the alarm and
when all occupants are safely outside the building.
7. ALARM MAINTENANCE
A regular program of fire alarm maintenance will help to keep your alarm in
good working order.
•
Test the alarm monthly making sure that all interconnected alarms in the
system sound within 10 seconds.
•
Vacuum the alarms every six months and wipe them with a damp cloth.
•
Do not paint the alarm.
A smoke alarm is a sensitive life-saving device. The life of this alarm can
be significantly reduced by adverse environments, incorrect location and a
failure to regularly clean and maintain it according to the instructions. Incorrect
location and a lack of reasonable care may also cause it to malfunction and will
invalidate the warranty.
8. TROUBLESHOOTING
The battery will last 10 years and is not replaceable. At the end of its life the
alarm will beep once every minute for a minimum of one month.
The life of the battery can be significantly shortened by periods of storage
or use in temperatures below 5°C or above 30°C. It will also be shortened
by frequent or extended periods in full alarm often caused by conditions
such as cigarette smoke, steam, aerosol spray and condensation. In these
circumstances the warranty will be void.
If this happens at night you can press the test button to silence the battery
warning for 10 hours. Replace the alarm as soon as possible.
Problems are indicated in five ways:
•
The alarm beeps twice every minute indicating a malfunction.
•
The alarm beeps once every minute indicating a low battery.
•
The full alarm sounds for no reason. (A repeating series of three beeps
with flashing light)
•
The alarm does not sound when pressing the test button.
•
The test button light remains steadily on or off. (i.e. does not flash
approximately once every minute, when the unit is not in alarm)
Inspect for obvious damage. Check that the alarm has been installed in
accordance with the instructions. In the case of repeated nuisance alarms, check
that it is free from dust, cobwebs and external contamination from such things as
cigarette smoke, drying paint, spray from household aerosols and steam that will
ultimately shorten the life of the alarm and invalidate the warranty.
If this does not correct the problem, do NOT attempt to repair. There are no user
serviceable parts internally. If the smoke alarm is within the warranty period
and terms, indicate the nature of the problem and return the unit with proof of
purchase to the address at the end of this manual. Units beyond warranty cannot
be economically repaired.
9. PRODUCT WARRANTY
UltraFire guarantees to you, as a purchaser, that the enclosed fire alarm will
be free from defects in material, workmanship or design under normal use and
service for a period of 10 years.
This Guarantee is not assignable. Our liability to you, under this guarantee is
limited to repairing or replacing any part which we find to be defective in material,
workmanship or design, free of charge to the customer, upon sending the alarm
with proof of date of purchase, postage paid to
UltraFire, 33 West Street, Alford,
Lincolnshire, LN13 9FX, United Kingdom.
The terms of this guarantee will not
apply in the following circumstances: If the alarm has been modified, dismantled,
contaminated, damaged, neglected or otherwise abused or altered following
the date of purchase, or if it fails to operate due to incorrect siting, installation,
maintenance or inadequate or over voltage AC electrical power, or damage
caused by failure to abide by the instructions supplied. It is specifically drawn to
the users attention that substantial periods in alarm will shorten alarm life, during
which time the fire alarm will have provided valuable protection; no Claim under
the guarantee will be entertained.
The liability of UltraFire, arising from the sale of this alarm or under the terms of
this guarantee shall not in any case exceed the cost of replacement of the alarm.
In no case, shall UltraFire be liable for consequential loss or damage resulting
from the failure of the alarm or the breach of this or any other guarantee, express
or implied or for damage caused by failure to abide by the instructions supplied.
This guarantee does not affect your statutory rights.
UltraFire
33 West Street, Alford, Lincolnshire, LN13 9FX, United Kingdom
Telephone: 0800 978 8262
Email: support@ultra-fire.co.uk
UltraFire
ULLS10 2797-CPR-749677
BS EN 14604: 2005 KM 623822
USER MANUAL
ULLS10 OPTICAL
SMOKE ALARM
Optical Smoke
Alarm
DOC 1303 - V1.3